{"product_id":"ls-electric-hcum-amr-home-communication-unit","title":"LS Electric HCUM AMR Home Communication Unit (HCUM-DM\/AM\/C)","description":"\u003cp class=\"ps-intro\"\u003eLS Electric HCUM household communication units that collect data from remote-reading electronic kWh meters and gas, water, hot-water, heating and cooling utility meters and transmit it over RS-485 to the meter-reading center.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eCollects electricity (bi-directional), gas, water, hot water, heating and cooling readings\u003c\/li\u003e\n\u003cli\u003eRS-485 communication 9,600 bps, selectable 19,200 or 38,400 bps\u003c\/li\u003e\n\u003cli\u003eHCUM-DM\/AM powered at DC 12 V from the LD remote-reading meter\u003c\/li\u003e\n\u003cli\u003eHCUM-C compatible units for existing CCU \/ TTL meter-reading sites (AC 220 V)\u003c\/li\u003e\n\u003cli\u003ePulse-input versions with power-failure pulse counting backup (24-72 h)\u003c\/li\u003e\n\u003cli\u003eSelf-diagnosis LEDs for communication, operation and error status\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003ctd\u003eHousehold AMR communication terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eWall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003eHCUM-DM\/AM 2 W max., HCUM-C less than 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSize, HCUM-DM\/AM\u003c\/th\u003e\n\u003ctd\u003e33 x 104 x 56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSize, HCUM-C\u003c\/th\u003e\n\u003ctd\u003e44 x 108 x 56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing\u003c\/th\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eDM 100 g, AM 130 g, C 260-280 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric Electricity Meters \u0026amp; AMR System catalog C11551-04, p. 18-19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCUM-DM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HCUM-DM | Supply: DC 12 V from meter | Meter input: DC-PLC 2 ports | Comm. form: Standard | Field meter link: DC-PLC, LS protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCUM-AM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HCUM-AM | Supply: DC 12 V from meter | Meter input: Pulse 4 ports | Comm. form: Standard | Field meter link: Pulse counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCUM-C(A4)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HCUM-C compatible | Supply: AC 220 V | Meter input: Pulse 4 ports | Comm. form: Standard | Field meter link: Open-collector pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCUM-C(AR)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HCUM-C compatible | Supply: AC 220 V | Meter input: Pulse 5 ports | Comm. form: Standard\/router | Field meter link: Open-collector pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCUM-C(DS)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HCUM-C compatible | Supply: AC 220 V | Meter input: DC-PLC 2 ports | Comm. form: Standard | Field meter link: DC-PLC, LS protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCUM-C(DR)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HCUM-C compatible | Supply: AC 220 V | Meter input: DC-PLC 2 ports | Comm. form: Standard\/router | Field meter link: DC-PLC, LS protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCUM-C(ON)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HCUM-C compatible | Supply: AC 220 V | Meter input: DC-PLC 2 ports | Comm. form: Standard | Field meter link: DC-PLC, Omni protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCUM-C(OR)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HCUM-C compatible | Supply: AC 220 V | Meter input: DC-PLC 2 ports | Comm. form: Standard\/router | Field meter link: DC-PLC, Omni protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCUM-C(DM)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HCUM-C compatible | Supply: AC 220 V | Meter input: DC-PLC 2 ports | Comm. form: Standard | Field meter link: DC-PLC, Modbus to server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67521971192098,"sku":"HCUM-DM","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-hcum-amr-home-communication-unit.jpg?v=1791954613","url":"https:\/\/prosourcemro.com\/products\/ls-electric-hcum-amr-home-communication-unit","provider":"ProSource MRO","version":"1.0","type":"link"}