{"product_id":"ls-electric-lvss-low-voltage-soft-starter","title":"LS Electric LVSS Low Voltage Soft Starter (17-1080 A)","description":"\u003cp class=\"ps-intro\"\u003eLS Electric LVSS series three-phase SCR soft starters for 200-480 V motors from 4 kW to 670 kW, with touch-screen setup and iERS energy saving.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRated 17 A to 1080 A (Class 10); internal bypass up to LS-LVSS-309\u003c\/li\u003e\n\u003cli\u003eiERS intelligent energy saving reduces consumption at light load\u003c\/li\u003e\n\u003cli\u003eIn-line or in-delta (6-wire) connection for one size larger motor\u003c\/li\u003e\n\u003cli\u003e3.5 inch colour TFT touch screen, 17 languages, USB parameter upload\/download\u003c\/li\u003e\n\u003cli\u003eFull I2t motor overload, PTC input, programmable I\/O and PLC function\u003c\/li\u003e\n\u003cli\u003eModbus RTU standard; Ethernet\/IP, Modbus TCP, Profibus DP via Anybus option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e208\/230\/400\/460 V, 45-65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesignation\u003c\/th\u003e\n\u003ctd\u003e3-phase SCR energy saving motor controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent limit\u003c\/th\u003e\n\u003ctd\u003e4.5 x In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard duty\u003c\/th\u003e\n\u003ctd\u003eTrip Class 10, 3 x In 23 s \/ 3.5 x In 17 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInputs\/outputs\u003c\/th\u003e\n\u003ctd\u003e3 NO + 1 NC relays, 3 DI, PTC, 0-10V\/4-20mA AI and AO, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData logging\u003c\/th\u003e\n\u003ctd\u003e4 GB, over 3.5 million events, CSV export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eIEC 60947-4-2:2012; CE, cETL, KC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient\u003c\/th\u003e\n\u003ctd\u003e-20 to 50 C (Size 4-5: 40 C), up to 60 C derated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric LV Soft Starter LVSS catalog C040C1-01 (2022-03), p. 6-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-101\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 17 A | Motor kW 230\/400\/440V: 4\/7.5\/7.5 | Frame size: Size 1 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-103\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 22 A | Motor kW 230\/400\/440V: 5.5\/11\/11 | Frame size: Size 1 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-105\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 29 A | Motor kW 230\/400\/440V: 7.5\/15\/15 | Frame size: Size 1 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-107\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 35 A | Motor kW 230\/400\/440V: 7.5\/18.5\/18.5 | Frame size: Size 1 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-109\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 41 A | Motor kW 230\/400\/440V: 11\/22\/22 | Frame size: Size 1 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-111\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 55 A | Motor kW 230\/400\/440V: 15\/30\/30 | Frame size: Size 1 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-113\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 66 A | Motor kW 230\/400\/440V: 18.5\/37\/37 | Frame size: Size 1 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-115\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 80 A | Motor kW 230\/400\/440V: 22\/45\/45 | Frame size: Size 1 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-117\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 100 A | Motor kW 230\/400\/440V: 30\/55\/55 | Frame size: Size 1 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-201\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 132 A | Motor kW 230\/400\/440V: 37\/75\/90 | Frame size: Size 2 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-203\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 160 A | Motor kW 230\/400\/440V: 45\/90\/110 | Frame size: Size 2 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-205\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 195 A | Motor kW 230\/400\/440V: 55\/110\/132 | Frame size: Size 2 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-301\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 242 A | Motor kW 230\/400\/440V: 75\/132\/150 | Frame size: Size 3 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-303\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 302 A | Motor kW 230\/400\/440V: 90\/160\/185 | Frame size: Size 3 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-305\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 361 A | Motor kW 230\/400\/440V: 110\/200\/220 | Frame size: Size 3 | Control voltage: 24 V DC \/ 110 V AC \/ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-307-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 430 A | Motor kW 230\/400\/440V: 132\/250\/280 | Frame size: Size 3 | Control voltage: 110 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-307-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 430 A | Motor kW 230\/400\/440V: 132\/250\/280 | Frame size: Size 3 | Control voltage: 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-309-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 500 A | Motor kW 230\/400\/440V: 160\/280\/315 | Frame size: Size 3 | Control voltage: 110 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-309-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 500 A | Motor kW 230\/400\/440V: 160\/280\/315 | Frame size: Size 3 | Control voltage: 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-401-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 610 A | Motor kW 230\/400\/440V: 200\/355\/375 | Frame size: Size 4 | Control voltage: 110 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-401-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 610 A | Motor kW 230\/400\/440V: 200\/355\/375 | Frame size: Size 4 | Control voltage: 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-403-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 722 A | Motor kW 230\/400\/440V: 220\/400\/425 | Frame size: Size 4 | Control voltage: 110 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-403-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 722 A | Motor kW 230\/400\/440V: 220\/400\/425 | Frame size: Size 4 | Control voltage: 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-501-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 850 A | Motor kW 230\/400\/440V: 280\/500\/530 | Frame size: Size 5 | Control voltage: 110 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-501-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 850 A | Motor kW 230\/400\/440V: 280\/500\/530 | Frame size: Size 5 | Control voltage: 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-503-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 960 A | Motor kW 230\/400\/440V: 315\/560\/600 | Frame size: Size 5 | Control voltage: 110 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-503-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 960 A | Motor kW 230\/400\/440V: 315\/560\/600 | Frame size: Size 5 | Control voltage: 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-505-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 1080 A | Motor kW 230\/400\/440V: 355\/630\/670 | Frame size: Size 5 | Control voltage: 110 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLS-LVSS-505-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current (Class 10): 1080 A | Motor kW 230\/400\/440V: 355\/630\/670 | Frame size: Size 5 | Control voltage: 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67521969127714,"sku":"LS-LVSS-101","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-lvss-low-voltage-soft-starter.jpg?v=1791954613","url":"https:\/\/prosourcemro.com\/products\/ls-electric-lvss-low-voltage-soft-starter","provider":"ProSource MRO","version":"1.0","type":"link"}