{"product_id":"ls-electric-metasol-mc-mt-covers-barriers-mounting-accessories","title":"LS Electric Metasol MC\/MT Covers, Barriers and Mounting Accessories","description":"\u003cp class=\"ps-intro\"\u003eLS Electric Metasol contactor and overload-relay accessories: AP terminal and safety covers, AI insulation barriers, AC capacitor units, UZ separate mounting units and UM remote reset units.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eAP standard and AP\/T transparent terminal covers for 18AF to 800AF contactors\u003c\/li\u003e\n\u003cli\u003eAP-9 \/ AP-185 safety covers prevent accidental manual operation and arc exposure\u003c\/li\u003e\n\u003cli\u003eAI insulation barriers between phases for 150AF to 2650AF and MCi contactors\u003c\/li\u003e\n\u003cli\u003eAC-9\/50\/75 capacitor units convert MC contactors for capacitor-bank switching\u003c\/li\u003e\n\u003cli\u003eUZ units mount MT overload relays separately; UM units reset them from the panel door\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eLS Electric Metasol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCovers per contactor\u003c\/th\u003e\n\u003ctd\u003e2 terminal covers; 4 insulation barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacitor unit standard\u003c\/th\u003e\n\u003ctd\u003eIEC 60947-5-1, AC-15 6 A at 120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRemote reset\u003c\/th\u003e\n\u003ctd\u003eCommon to all MT frames; 8 mm panel cut-out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric Metasol MS catalog C04001-37 (2026-09), p. 91, 95, 97, 109-110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP-18\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, standard | For: MC-6a to 18a (18AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP\/T-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, transparent | For: MC-6a to 18a (18AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, standard | For: MC-9b to 22b (22AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP\/T-9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, transparent | For: MC-9b to 22b (22AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP-40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, standard | For: MC-32a, 40a (40AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP\/T-32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, transparent | For: MC-32a, 40a (40AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP-65\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, standard | For: MC-50a, 65a (65AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP\/T-50\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, transparent | For: MC-50a, 65a (65AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP-100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, standard | For: MC-75a to 100a (100AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP\/T-75\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, transparent | For: MC-75a to 100a (100AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP-150\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, standard | For: MC-130a, 150a (150AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP\/T-130\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, transparent | For: MC-130a, 150a (150AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP-220\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, standard | For: MC-185a, 225a (225AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP\/T-185\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, transparent | For: MC-185a, 225a (225AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP-400\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, standard | For: MC-265a to 400a (400AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP\/T-265\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, transparent | For: MC-265a to 400a (400AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP-800\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, standard | For: MC-500a to 800a (800AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP\/T-500\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Terminal cover, transparent | For: MC-500a to 800a (800AF) | Note: 2 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP-185\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Safety cover | For: MC-185a to 1260a | Note: Prevents accidental operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAI-180\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Insulation barrier | For: MC-130a to 400a | Note: 4 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAI-800\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Insulation barrier | For: MC-500a to 1260a | Note: 4 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAI-2100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Insulation barrier | For: MC-1400a to 2100a | Note: 4 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAI-2650\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Insulation barrier | For: MC-2650a, MCi-1700 to 2650 | Note: 4 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAI-1260\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Insulation barrier | For: MCi-900 to 1260 | Note: 4 pcs per contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC-75\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Capacitor unit (pre-loading resistor) | For: MC-75a to 100a | Note: Built-in 1NC, Ith 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUZ-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Overload relay separate mounting unit | For: MT-12 | Note: Weight 35 g, DIN rail or screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUZ-63S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Overload relay separate mounting unit | For: MT-63 (screw) | Note: Weight 134 g, DIN rail or screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUZ-63L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Overload relay separate mounting unit | For: MT-63 (lug) | Note: Weight 134 g, DIN rail or screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUZ-95S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Overload relay separate mounting unit | For: MT-95 (screw) | Note: Weight 230 g, DIN rail or screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUZ-95L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Overload relay separate mounting unit | For: MT-95 (lug) | Note: Weight 230 g, DIN rail or screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUZ-150S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Overload relay separate mounting unit | For: MT-150 (screw) | Note: Weight 284 g, DIN rail or screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUZ-150L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Overload relay separate mounting unit | For: MT-150 (lug) | Note: Weight 284 g, DIN rail or screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUM-7R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Overload relay remote reset unit | For: MT series, all frames | Note: Cable length 700 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUM-9R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Overload relay remote reset unit | For: MT series, all frames | Note: Cable length 900 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67521959559458,"sku":"AP-18","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-metasol-mc-mt-covers-barriers-mounting-accessories.jpg?v=1791954616","url":"https:\/\/prosourcemro.com\/products\/ls-electric-metasol-mc-mt-covers-barriers-mounting-accessories","provider":"ProSource MRO","version":"1.0","type":"link"}