{"product_id":"ls-electric-metasol-mms-100hi-instantaneous-mcp-manual-motor-starter-100af-high-range-50100a-3-pole-rotary-handle","title":"LS Electric Metasol MMS-100HI Instantaneous (MCP) Manual Motor Starter (100AF, High Range 50~100A, 3-Pole, Rotary Handle)","description":"\u003cp class=\"ps-intro\"\u003eMetasol MMS-100HI Manual Motor Starter — High Range (50~100A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eMotor Circuit Protector — instantaneous magnetic trip only (no overload, no phase-loss)\u003c\/li\u003e\n\u003cli\u003ePair with separate overload relay (e.g., MT-series TOR)\u003c\/li\u003e\n\u003cli\u003eHigh range for motors 11~45kW (30kW @ 220V \/ 45kW @ 440V)\u003c\/li\u003e\n\u003cli\u003eFrame: 100AF, width 70mm\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage Ui = 1000V, impulse Uimp = 8kV\u003c\/li\u003e\n\u003cli\u003eUp to 690V Ue, 50\/60Hz\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e100AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacity Band\u003c\/th\u003e\n\u003ctd\u003eHigh Range (50~100A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eInstantaneous (MCP) (HI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePole\u003c\/th\u003e\n\u003ctd\u003e3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdjustment Range\u003c\/th\u003e\n\u003ctd\u003eFixed (instantaneous only, no thermal adjustment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage Ue\u003c\/th\u003e\n\u003ctd\u003eUp to 690V AC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Insulation Ui\u003c\/th\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpulse Uimp\u003c\/th\u003e\n\u003ctd\u003e8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Protection\u003c\/th\u003e\n\u003ctd\u003eNone — pair with external TOR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase-Loss Protection\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHandle\u003c\/th\u003e\n\u003ctd\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip Test Button\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMS-100HI\/50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMetasol MMS-100HI 50A, Standard terminal, Instantaneous (MCP) (High Range) | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 50A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 650A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50\/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail \/ panel screw \/ 75mm DIN rail | 3-Phase Motor Rating: 230V\/11kW | 400V\/22kW | 690V\/45kW | 230V\/15HP | 460V\/40HP | 575V\/50HP | Standards: IEC 60947-1\/-2\/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMS-100HI\/50A O-RING TERMINAL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMetasol MMS-100HI 50A, O-Ring Terminal terminal, Instantaneous (MCP) (High Range) | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 50A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 650A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50\/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail \/ panel screw \/ 75mm DIN rail | 3-Phase Motor Rating: 230V\/11kW | 400V\/22kW | 690V\/45kW | 230V\/15HP | 460V\/40HP | 575V\/50HP | Standards: IEC 60947-1\/-2\/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMS-100HI\/63A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMetasol MMS-100HI 63A, Standard terminal, Instantaneous (MCP) (High Range) | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 63A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 819A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50\/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail \/ panel screw \/ 75mm DIN rail | 3-Phase Motor Rating: 230V\/15kW | 400V\/30kW | 690V\/55kW | 230V\/20HP | 460V\/50HP | 575V\/60HP | Standards: IEC 60947-1\/-2\/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMS-100HI\/63A O-RING TERMINAL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMetasol MMS-100HI 63A, O-Ring Terminal terminal, Instantaneous (MCP) (High Range) | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 63A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 819A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50\/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail \/ panel screw \/ 75mm DIN rail | 3-Phase Motor Rating: 230V\/15kW | 400V\/30kW | 690V\/55kW | 230V\/20HP | 460V\/50HP | 575V\/60HP | Standards: IEC 60947-1\/-2\/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMS-100HI\/75A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMetasol MMS-100HI 75A, Standard terminal, Instantaneous (MCP) (High Range) | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 75A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 975A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50\/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail \/ panel screw \/ 75mm DIN rail | 3-Phase Motor Rating: 230V\/22kW | 400V\/37kW | 690V\/63kW | 230V\/25HP | 460V\/60HP | 575V\/75HP | Standards: IEC 60947-1\/-2\/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMS-100HI\/75A O-RING TERMINAL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMetasol MMS-100HI 75A, O-Ring Terminal terminal, Instantaneous (MCP) (High Range) | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 75A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 975A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50\/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail \/ panel screw \/ 75mm DIN rail | 3-Phase Motor Rating: 230V\/22kW | 400V\/37kW | 690V\/63kW | 230V\/25HP | 460V\/60HP | 575V\/75HP | Standards: IEC 60947-1\/-2\/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMS-100HI\/90A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMetasol MMS-100HI 90A, Standard terminal, Instantaneous (MCP) (High Range) | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 90A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 1170A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50\/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail \/ panel screw \/ 75mm DIN rail | 3-Phase Motor Rating: 230V\/30kW | 400V\/45kW | 690V\/75kW | 230V\/30HP | 460V\/75HP | 575V\/100HP | Standards: IEC 60947-1\/-2\/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMS-100HI\/90A O-RING TERMINAL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMetasol MMS-100HI 90A, O-Ring Terminal terminal, Instantaneous (MCP) (High Range) | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 90A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 1170A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50\/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail \/ panel screw \/ 75mm DIN rail | 3-Phase Motor Rating: 230V\/30kW | 400V\/45kW | 690V\/75kW | 230V\/30HP | 460V\/75HP | 575V\/100HP | Standards: IEC 60947-1\/-2\/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMS-100HI\/100A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMetasol MMS-100HI 100A, Standard terminal, Instantaneous (MCP) (High Range) | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 100A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 1300A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50\/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail \/ panel screw \/ 75mm DIN rail | 3-Phase Motor Rating: 230V\/30kW | 400V\/45kW | 690V\/90kW | 230V\/40HP | 460V\/75HP | 575V\/100HP | Standards: IEC 60947-1\/-2\/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMS-100HI\/100A O-RING TERMINAL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMetasol MMS-100HI 100A, O-Ring Terminal terminal, Instantaneous (MCP) (High Range) | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 100A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 1300A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50\/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail \/ panel screw \/ 75mm DIN rail | 3-Phase Motor Rating: 230V\/30kW | 400V\/45kW | 690V\/90kW | 230V\/40HP | 460V\/75HP | 575V\/100HP | Standards: IEC 60947-1\/-2\/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67396601217314,"sku":"LSE-MMS-100HI-HIGH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1511_3e7cc8fb-7916-488f-b5ec-c8fde42d2fa1.png?v=1790662043","url":"https:\/\/prosourcemro.com\/products\/ls-electric-metasol-mms-100hi-instantaneous-mcp-manual-motor-starter-100af-high-range-50100a-3-pole-rotary-handle","provider":"ProSource MRO","version":"1.0","type":"link"}