{"product_id":"ls-electric-metasol-mms-rs-shunt-release-trip-remote-trip-6-voltages","title":"LS Electric Metasol MMS RS Shunt Release Trip (Remote Trip, 6 Voltages)","description":"\u003cp class=\"ps-intro\"\u003eRS Shunt Release for remote tripping of Metasol MMS.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRight side-mount, single unit per MMS\u003c\/li\u003e\n\u003cli\u003eOperating voltage range 0.7~1.1×Us\u003c\/li\u003e\n\u003cli\u003eAvailable in 6 voltages: 24V, 110V, 220-230V, 240V, 380-400V, 415-440V (50\/60Hz)\u003c\/li\u003e\n\u003cli\u003eInrush 8.5VA\/6W, holding 3VA\/1.2W\u003c\/li\u003e\n\u003cli\u003eCRITICAL: do not apply trip signal continuously for more than 10 seconds\u003c\/li\u003e\n\u003cli\u003eMutually exclusive with RU and RUX (only one right-side device permitted)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eShunt Release (RS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003ctd\u003eTrips MMS on signal (remote trip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMount\u003c\/th\u003e\n\u003ctd\u003eRight side-mount (single unit only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible MMS\u003c\/th\u003e\n\u003ctd\u003eAll Metasol MMS frames (32\/63\/100AF, S\/H\/HI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Range\u003c\/th\u003e\n\u003ctd\u003e0.7~1.1 × Us (pickup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInrush Power\u003c\/th\u003e\n\u003ctd\u003e8.5VA \/ 6W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHolding Power\u003c\/th\u003e\n\u003ctd\u003e3VA \/ 1.2W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e110g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImportant\u003c\/th\u003e\n\u003ctd\u003eDo not apply trip signal for more than 10 seconds continuously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMutual Exclusion\u003c\/th\u003e\n\u003ctd\u003eCannot be installed simultaneously with RU or RUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-AC24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRS Shunt Release Trip, 24V 50Hz \/ 28V 60Hz | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 24V 50Hz \/ 28V 60Hz | Compatible MMS: All Metasol MMS frames (32\/63\/100AF, S\/H\/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA \/ 6W | Holding Power: 3VA \/ 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-AC110\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRS Shunt Release Trip, 110V 50Hz \/ 120V 60Hz | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 110V 50Hz \/ 120V 60Hz | Compatible MMS: All Metasol MMS frames (32\/63\/100AF, S\/H\/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA \/ 6W | Holding Power: 3VA \/ 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-AC220\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRS Shunt Release Trip, 220-230V 50Hz \/ 240-260V 60Hz | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 220-230V 50Hz \/ 240-260V 60Hz | Compatible MMS: All Metasol MMS frames (32\/63\/100AF, S\/H\/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA \/ 6W | Holding Power: 3VA \/ 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-AC240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRS Shunt Release Trip, 240V 50Hz \/ 277V 60Hz | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 240V 50Hz \/ 277V 60Hz | Compatible MMS: All Metasol MMS frames (32\/63\/100AF, S\/H\/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA \/ 6W | Holding Power: 3VA \/ 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-AC380\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRS Shunt Release Trip, 380-400V 50Hz \/ 440-460V 60Hz | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 380-400V 50Hz \/ 440-460V 60Hz | Compatible MMS: All Metasol MMS frames (32\/63\/100AF, S\/H\/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA \/ 6W | Holding Power: 3VA \/ 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-AC415\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRS Shunt Release Trip, 415-440V 50Hz \/ 460-480V 60Hz | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 415-440V 50Hz \/ 460-480V 60Hz | Compatible MMS: All Metasol MMS frames (32\/63\/100AF, S\/H\/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA \/ 6W | Holding Power: 3VA \/ 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67396601413922,"sku":"LSE-MMS-ACC-RS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1511_037841e0-13bf-4846-9ba1-a91c064567f5.png?v=1790662049","url":"https:\/\/prosourcemro.com\/products\/ls-electric-metasol-mms-rs-shunt-release-trip-remote-trip-6-voltages","provider":"ProSource MRO","version":"1.0","type":"link"}