{"product_id":"ls-electric-mini-gms-magnetic-starter-standard","title":"LS Electric Mini GMS Magnetic Starter (6-16 A, GTH-12M TOR)","description":"\u003cp class=\"ps-intro\"\u003eCompact non-reversing magnetic starters combining an LS Electric Mini contactor GMC-6M to 16M with a standard thermal overload relay GTH-12M, for small motors up to 5.5 kW at 380-440 V.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003ePre-assembled screw-terminal Mini contactor plus direct-mounted thermal overload relay\u003c\/li\u003e\n\u003cli\u003eFrames 6, 9, 12 and 16 A; AC-1 thermal current 20 A\u003c\/li\u003e\n\u003cli\u003e13 AC coil voltages from 24 to 550 V (50\/60 Hz, 2 W)\u003c\/li\u003e\n\u003cli\u003eBuilt-in 1NO or 1NC auxiliary contact (specify at order)\u003c\/li\u003e\n\u003cli\u003eOverload relay setting ranges from 0.1-0.16 A to 12-16 A\u003c\/li\u003e\n\u003cli\u003eScrew or 35 mm DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain contacts\u003c\/th\u003e\n\u003ctd\u003e3NO (3-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal current (Ith)\u003c\/th\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil type\u003c\/th\u003e\n\u003ctd\u003eAC 50\/60 Hz, 2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload relay\u003c\/th\u003e\n\u003ctd\u003eGTH-12M (standard, 3-pole 2-element)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical life\u003c\/th\u003e\n\u003ctd\u003e1 million operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical life\u003c\/th\u003e\n\u003ctd\u003e10 million operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eScrew \/ 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eIEC 60947-4-1, K 60947, UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric Mini MS catalog C04061-03 (2026-09), p. 14, 24-25, 28, 52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC24\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC36\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC48\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC110\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC120\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC220\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC277\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC380\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC400\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC440\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC480\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC500\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-6M\/AC550\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-6M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.2 kW \/ 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC24\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC36\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC48\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC110\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC120\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC220\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC277\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC380\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC400\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC440\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC480\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC500\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-9M\/AC550\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-9M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 2.7 kW \/ 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC24\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC36\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC48\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC110\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC120\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC220\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC277\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC380\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC400\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC440\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC480\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC500\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-12M\/AC550\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-12M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC24\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 24 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC36\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 36 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC48\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 48 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC110\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 110 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC120\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 120 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC220\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 220 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC277\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 277 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC380\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 380 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC400\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 400 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC440\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 440 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC480\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 480 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC500\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 500 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/10\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NO | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/0.16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.1-0.16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/0.25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.16-0.25 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.25-0.4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/0.63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.4-0.63 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 0.63-1 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/1.6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1-1.6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 1.6-2.5 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 2.5-4 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 4-6 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 5-8 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 6-9 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 7-10 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 9-13 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMS-16M\/AC550\/01\/16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMS-16M | Coil: AC 550 V 50\/60 Hz | Auxiliary contact: 1NC | TOR setting: 12-16 A | AC-3 at 380-440 V: 5.5 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67521966768418,"sku":"GMS-6M\/AC24\/10\/0.16","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-mini-gms-magnetic-starter-standard.jpg?v=1791954614","url":"https:\/\/prosourcemro.com\/products\/ls-electric-mini-gms-magnetic-starter-standard","provider":"ProSource MRO","version":"1.0","type":"link"}