{"product_id":"ls-electric-mini-mc-9m-standard-magnetic-contactor-9a-ac-3-cage-clamp-ac-50-60hz","title":"LS Electric Mini MC-9M Standard Magnetic Contactor (9A AC-3, Cage Clamp, AC 50\/60Hz)","description":"\u003cp class=\"ps-intro\"\u003eMeta-MEC Mini Magnetic Contactor MC-9M, Cage Clamp terminals, AC 50\/60Hz coil (2W consumption). 2.2kW @ 220-240V \/ 4kW @ 380-440V. 3-pole and 4-pole variants.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eCompliant with IEC 60947-4, K 60947, UL 508\u003c\/li\u003e\n\u003cli\u003eKEMA Type Tested\u003c\/li\u003e\n\u003cli\u003eCertifications: UL, CE, CCC, KS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current AC-3\u003c\/th\u003e\n\u003ctd\u003e9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Power\u003c\/th\u003e\n\u003ctd\u003e2W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal\u003c\/th\u003e\n\u003ctd\u003eCage Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC24\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC24V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC24V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC24\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC24V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC24V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC24V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC24V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC24\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC24V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC24V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC36\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC36V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC36V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC36\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC36V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC36V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC36\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC36V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC36V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC36\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC36V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC36V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC48\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC48V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC48V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC48\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC48V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC48V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC48\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC48V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC48V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC48\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC48V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC48V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC110\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC110V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC110V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC110\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC110V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC110V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC110\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC110V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC110V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC110\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC110V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC110V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC120\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC120V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC120V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC120\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC120V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC120V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC120\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC120V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC120V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC120\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC120V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC120V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC220\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC220V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC220V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC220\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC220V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC220V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC220\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC220V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC220V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC220\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC220V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC220V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC277\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC277V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC277V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC277\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC277V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC277V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC277\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC277V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC277V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC277\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC277V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC277V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC380\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC380V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC380V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC380\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC380V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC380V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC380\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC380V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC380V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC380\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC380V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC380V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC400\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC400V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC400V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC400\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC400V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC400V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC400\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC400V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC400V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC400\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC400V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC400V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC440\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC440V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC440V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC440\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC440V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC440V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC440\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC440V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC440V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC440\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC440V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC440V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC480\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC480V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC480V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC480\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC480V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC480V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC480\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC480V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC480V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC480\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC480V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC480V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC500\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC500V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC500V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC500\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC500V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC500V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC500\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC500V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC500V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC500\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC500V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC500V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC550\/10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC550V, 1a NO | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC550V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1a NO | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/AC550\/01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M, Cage Clamp, AC550V, 1b NC | Pole: 3-Pole | Frame: MC-9M | Rated Current AC-3: 9A | Coil: AC550V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Aux Contact: 1b NC | Capacity: 2.2kW@220V \/ 4kW@440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC550\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (4NO), Cage Clamp, AC550V | Pole: 4-Pole | Main Contact: 4 NO | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC550V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMC-9MC\/4\/AC550\/2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMini MC-9M\/4 (2NO+2NC), Cage Clamp, AC550V | Pole: 4-Pole | Main Contact: 2 NO + 2 NC | Frame: MC-9M\/4 | Rated Current AC-3: 9A | Coil: AC550V | Coil Power: 2W | Frequency: 50\/60Hz | Terminal: Cage Clamp | Note: No aux contacts on 4-pole variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67396598399266,"sku":"LSE-MINI-MC-9M-CAGE-AC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1510_c8e5c61d-90ee-47c6-a325-369e3c8ceb34.png?v=1790661948","url":"https:\/\/prosourcemro.com\/products\/ls-electric-mini-mc-9m-standard-magnetic-contactor-9a-ac-3-cage-clamp-ac-50-60hz","provider":"ProSource MRO","version":"1.0","type":"link"}