{"product_id":"ls-electric-prime-mec-din-power-fuse-link","title":"LS Electric Prime-MEC DIN Power Fuse Link (LFL, 3.6-24kV)","description":"\u003cp class=\"ps-intro\"\u003eLS Electric Prime-MEC DIN-standard current-limiting power fuse links LFL for 3.6\/7.2 kV and 24 kV general-purpose circuits from 5 to 200 A.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eCurrent-limiting design clears short circuits within half a cycle and limits let-through peak current\u003c\/li\u003e\n\u003cli\u003eStriker with 30 mm travel and 5 kgf force for trip indication, mechanical interlock and LBS tripping\u003c\/li\u003e\n\u003cli\u003eBreaking capacity 40 kA rms (25 kA for 24 kV 75-200 A)\u003c\/li\u003e\n\u003cli\u003eCompact sealed construction suited to cubicles and narrow spaces\u003c\/li\u003e\n\u003cli\u003eFor transformer, motor and capacitor loads per the selection tables; indoor use\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003eDIN dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eGeneral load (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFerrule diameter\u003c\/th\u003e\n\u003ctd\u003e45 mm, striker pin 7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eIndoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMatching holders\u003c\/th\u003e\n\u003ctd\u003eLFH-6G-D1HB, LFH-6G-D2HB, LFH-20G-D2HB\/D2HC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType designation\u003c\/th\u003e\n\u003ctd\u003eLFL-[kV code]G-[A]B\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric Prime-MEC Power Fuse catalog C09511-18 (2023-03), p. 5-7, 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3\/6G-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6\/7.2 kV | Rated current: 5 A | Length x dia. (A x B): 192 x 55 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D1HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3\/6G-10B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6\/7.2 kV | Rated current: 10 A | Length x dia. (A x B): 192 x 55 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D1HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3\/6G-20B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6\/7.2 kV | Rated current: 20 A | Length x dia. (A x B): 192 x 55 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D1HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3\/6G-30B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6\/7.2 kV | Rated current: 30 A | Length x dia. (A x B): 192 x 55 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D1HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3\/6G-40B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6\/7.2 kV | Rated current: 40 A | Length x dia. (A x B): 192 x 55 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D1HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3\/6G-50B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6\/7.2 kV | Rated current: 50 A | Length x dia. (A x B): 192 x 55 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D1HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3\/6G-60B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6\/7.2 kV | Rated current: 63 A | Length x dia. (A x B): 192 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D1HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3\/6G-75B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6\/7.2 kV | Rated current: 75 A | Length x dia. (A x B): 192 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D1HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3\/6G-100B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6\/7.2 kV | Rated current: 100 A | Length x dia. (A x B): 192 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D1HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3\/6G-125B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6\/7.2 kV | Rated current: 125 A | Length x dia. (A x B): 292 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3G-160B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6 kV | Rated current: 160 A | Length x dia. (A x B): 292 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-3G-200B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 3.6 kV | Rated current: 200 A | Length x dia. (A x B): 292 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-6G-160B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 7.2 kV | Rated current: 160 A | Length x dia. (A x B): 292 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-6G-200B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 7.2 kV | Rated current: 200 A | Length x dia. (A x B): 292 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-6G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 5 A | Length x dia. (A x B): 442 x 55 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-10B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 10 A | Length x dia. (A x B): 442 x 55 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-16B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 16 A | Length x dia. (A x B): 442 x 55 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-20B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 20 A | Length x dia. (A x B): 442 x 55 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-25B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 25 A | Length x dia. (A x B): 442 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-30B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 30 A | Length x dia. (A x B): 442 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-40B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 40 A | Length x dia. (A x B): 442 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-50B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 50 A | Length x dia. (A x B): 442 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-60B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 63 A | Length x dia. (A x B): 442 x 77 mm | Breaking current: 40 kA | Min. breaking current: 5 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-75C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 75 A | Length x dia. (A x B): 442 x 87 mm | Breaking current: 25 kA | Min. breaking current: 5 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-100C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 100 A | Length x dia. (A x B): 442 x 87 mm | Breaking current: 25 kA | Min. breaking current: 6 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-125B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 125 A | Length x dia. (A x B): 442 x 87 mm | Breaking current: 25 kA | Min. breaking current: 6 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-160B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 160 A | Length x dia. (A x B): 442 x 87 mm | Breaking current: 25 kA | Min. breaking current: 6 In | Fuse holder: LFH-20G-D2HB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLFL-20G-200B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated voltage: 24 kV | Rated current: 200 A | Length x dia. (A x B): 537 x 87 mm | Breaking current: 25 kA | Min. breaking current: 6 In | Fuse holder: LFH-20G-D2HC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67521973256482,"sku":"LFL-3\/6G-5B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-prime-mec-din-power-fuse-link.jpg?v=1791954614","url":"https:\/\/prosourcemro.com\/products\/ls-electric-prime-mec-din-power-fuse-link","provider":"ProSource MRO","version":"1.0","type":"link"}