{"product_id":"ls-electric-susol-mc-50d-capacitor-bank-contactor-40kvar-400v-63af","title":"LS Electric Susol MC-50(D) Capacitor Bank Contactor (40kVar @ 400V, 63AF)","description":"\u003cp class=\"ps-intro\"\u003eLS ELECTRIC Susol MC-50(D) Capacitor Bank Contactor. | Application: Power factor correction, capacitor bank switching with inrush limiting (up to 60×In) for single-step or multi-step capacitor banks. | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) — no standard aux | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Pre-loading damping resistor included | No serial resistance heat loss | Surge elimination | Extended capacitor system life | Coil: AC 50\/60Hz only | Mounting: 35mm DIN rail \/ screw | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA — see RFQ table for specific MPN with coil voltage.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e63AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBase contactor\u003c\/th\u003e\n\u003ctd\u003eMC-50(D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacitor unit type\u003c\/th\u003e\n\u003ctd\u003eAC-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePole\u003c\/th\u003e\n\u003ctd\u003e3P (3a)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacitor capacity\u003c\/th\u003e\n\u003ctd\u003e20kVar @ 220-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e58A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInrush limiting\u003c\/th\u003e\n\u003ctd\u003eup to 60×In via damping resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003eIEC60947-4-1 AC-6b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproval\u003c\/th\u003e\n\u003ctd\u003eIEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC24V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 24V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 24V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC32V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 32V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 32V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC36V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 36V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 36V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC42V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 42V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 42V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC48V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 48V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 48V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC80V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 80V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 80V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC100V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 100V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 100V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC110V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 110V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 110V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC120V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 120V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 120V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC220V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 220V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 220V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC230V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 230V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 230V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC240V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 240V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 240V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC380V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 380V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 380V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC400V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 400V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 400V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC415V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 415V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 415V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC440V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 440V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 440V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC500V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 500V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 500V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC550V\/50Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 550V 50Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 550V 50Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC24V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 24V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 24V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC48V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 48V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 48V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC100V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 100V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 100V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC110V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 110V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 110V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC120V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 120V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 120V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC200V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 200V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 200V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC208V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 208V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 208V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC220V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 220V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 220V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC230V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 230V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 230V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC240V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 240V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 240V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC277V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 277V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 277V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC380V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 380V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 380V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC440V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 440V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 440V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC480V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 480V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 480V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMC-50(D)\/AC-50\/AC600V\/60Hz\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MC-50(D) capacitor bank (AC-50), AC 600V 60Hz | Frame: 63AF | Base contactor: MC-50(D) | Capacitor unit type: AC-50 | Pole: 3P (3a) | Coil: AC 600V 60Hz | Capacitor capacity: 20kVar @ 220-240V | 40kVar @ 400-440V | 58kVar @ 600-690V | Rated current: 58A | Inrush limiting: up to 60×In via damping resistor | Standard: IEC60947-4-1 AC-6b | Approval: IEC, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67396597809442,"sku":"LSE-SUSOL-MC-50-CAP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1509_f18def8e-c1cd-4a04-9e56-6a5b8d477489.png?v=1790661927","url":"https:\/\/prosourcemro.com\/products\/ls-electric-susol-mc-50d-capacitor-bank-contactor-40kvar-400v-63af","provider":"ProSource MRO","version":"1.0","type":"link"}