{"product_id":"ls-electric-susol-utd-ul-dc-1500v-mccb","title":"LS Electric Susol UTD UL DC 1500 V MCCB (40-550 A, 4P)","description":"\u003cp class=\"ps-intro\"\u003eLS Electric Susol UTD250, UTD400 and UTD600 UL-listed 1500 Vdc molded case circuit breakers, 40-550 A, 4 poles, for photovoltaic (UL489B) and battery\/DC distribution (UL489) systems, dual certified to IEC 60947-2.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eMaximum voltage DC 1500 V; UL interrupting rating at nominal 1250 Vdc: E\/ET 20 kA, N\/NT 50 kA, H\/HT 65 kA\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2 Icu at 1500 Vdc: E 20 kA, N 40 kA, H 50 kA; T suffix = 100% rated, without = 80% rated\u003c\/li\u003e\n\u003cli\u003eUL489 (ULF) ratings at 40 C for BPS use; UL489B (ULB) ratings at 50 C for PV use\u003c\/li\u003e\n\u003cli\u003eFTU fixed or FMU adjustable thermal, fixed magnetic trip units\u003c\/li\u003e\n\u003cli\u003eCompact frames: UTD250 140 x 200 x 92 mm, UTD400 186.5 x 290 x 110 mm, UTD600 186.5 x 340 x 110 mm\u003c\/li\u003e\n\u003cli\u003eOrdering format: UTD + AF + type + trip unit + In + 4P + standard (e.g. UTD600-ET-FTU-550A-4P-ULF)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame size\u003c\/th\u003e\n\u003ctd\u003e250 \/ 400 \/ 600 AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage (Ui)\u003c\/th\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse voltage (Uimp)\u003c\/th\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUtilization category\u003c\/th\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eUTD250 2.76 kg, UTD400 6.99 kg, UTD600 7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL 489, UL 489B, CSA, IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric Susol UL DC MCCB leaflet C010I1-04 (2024-03), p. 2-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FMU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FMU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FMU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FMU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FMU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FMU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-40A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FTU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FMU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FMU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FMU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FMU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-E-FMU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FMU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FMU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FMU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FMU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FMU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FMU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-40A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FTU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FMU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FMU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FMU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FMU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-ET-FMU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FMU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FMU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FMU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FMU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FMU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FMU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-40A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FTU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FMU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FMU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FMU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FMU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-N-FMU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FMU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FMU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FMU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FMU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FMU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FMU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-40A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FTU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FMU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FMU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FMU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FMU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-NT-FMU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FMU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FMU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FMU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FMU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FMU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FMU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-40A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FTU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FMU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FMU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FMU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FMU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-H-FMU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FMU-60A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FMU-80A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FMU-100A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FMU-150A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FMU-200A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FMU-250A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-40A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 40 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FTU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FMU-60A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 60 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FMU-80A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 80 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FMU-100A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 100 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FMU-150A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 150 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD250-HT-FMU-200A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD250 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 200 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-E-FTU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-E-FTU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-E-FTU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-E-FMU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-E-FMU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-E-FMU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-E-FTU-250A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-E-FTU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-E-FMU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-ET-FTU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-ET-FTU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-ET-FTU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-ET-FMU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-ET-FMU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-ET-FMU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-ET-FTU-250A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-ET-FTU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-ET-FMU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-N-FTU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-N-FTU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-N-FTU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-N-FMU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-N-FMU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-N-FMU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-N-FTU-250A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-N-FTU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-N-FMU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-NT-FTU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-NT-FTU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-NT-FTU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-NT-FMU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-NT-FMU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-NT-FMU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-NT-FTU-250A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-NT-FTU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-NT-FMU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-H-FTU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-H-FTU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-H-FTU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-H-FMU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-H-FMU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-H-FMU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-H-FTU-250A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-H-FTU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-H-FMU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-HT-FTU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-HT-FTU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-HT-FTU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-HT-FMU-275A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-HT-FMU-300A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-HT-FMU-400A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-HT-FTU-250A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 250 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-HT-FTU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD400-HT-FMU-275A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD400 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 275 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FTU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FTU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FTU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FMU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FMU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FMU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FTU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FTU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FTU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FMU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FMU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-E-FMU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: E, 80% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FTU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FTU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FTU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FMU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FMU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FMU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FTU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FTU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FTU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FMU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FMU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-ET-FMU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: ET, 100% rated, UL 20 kA \/ IEC 20 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FTU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FTU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FTU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FMU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FMU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FMU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FTU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FTU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FTU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FMU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FMU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-N-FMU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: N, 80% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FTU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FTU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FTU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FMU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FMU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FMU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FTU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FTU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FTU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FMU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FMU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-NT-FMU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: NT, 100% rated, UL 50 kA \/ IEC 40 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FTU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FTU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FTU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FMU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FMU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FMU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FTU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FTU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FTU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FMU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FMU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-H-FMU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: H, 80% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FTU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FTU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FTU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FMU-450A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FMU-500A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 500 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FMU-550A-4P-ULF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 550 A | Standard: UL489 (BPS, 40 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FTU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FTU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FTU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FTU (fixed thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FMU-300A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 300 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FMU-400A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 400 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTD600-HT-FMU-450A-4P-ULB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame: UTD600 | Type: HT, 100% rated, UL 65 kA \/ IEC 50 kA | Trip unit: FMU (adj. thermal, fixed magnetic) | Rated current In: 450 A | Standard: UL489B (PV, 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67521960608034,"sku":"UTD250-E-FTU-60A-4P-ULF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-susol-utd-ul-dc-1500v-mccb.jpg?v=1791954615","url":"https:\/\/prosourcemro.com\/products\/ls-electric-susol-utd-ul-dc-1500v-mccb","provider":"ProSource MRO","version":"1.0","type":"link"}