{"product_id":"ls-electric-susol-uts800-ul-mccb","title":"LS Electric Susol UTS800 UL 489 MCCB (400-800 A, digital OCR)","description":"\u003cp class=\"ps-intro\"\u003eLS Electric Susol UTS800 UL 489 molded case circuit breakers carry a factory-fitted digital trip relay (OCR) in Normal, Ammeter, Power-meter or Super-meter versions for 400-800 A feeders.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eUL 489 listed 3P breaker, HACR rated, up to 600 Vac\u003c\/li\u003e\n\u003cli\u003eDigital OCR with long-time, short-time, instantaneous and ground-fault protection\u003c\/li\u003e\n\u003cli\u003eA\/P\/S relays add metering, fault recording, ZSI and Modbus RS-485 \/ Profibus-DP communication\u003c\/li\u003e\n\u003cli\u003eP and S relays add voltage, frequency, power and (S) harmonic analysis\u003c\/li\u003e\n\u003cli\u003eSelf-powered or externally powered control circuit (AC\/DC 100-250 V or DC 24-60 V)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame size\u003c\/th\u003e\n\u003ctd\u003e800 AF, 3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage (Ui)\u003c\/th\u003e\n\u003ctd\u003eAC 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse voltage (Uimp)\u003c\/th\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUL 489 interrupting rating (240\/480\/600 V)\u003c\/th\u003e\n\u003ctd\u003eN 50\/35\/18 kA, H 100\/65\/35 kA, L 150\/100\/50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIEC 60947-2 Icu (220-240\/380-415 V)\u003c\/th\u003e\n\u003ctd\u003eN 65\/35 kA, H 100\/65 kA, L 150\/100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e210 x 327.2 x 152.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOCR settings\u003c\/th\u003e\n\u003ctd\u003eIr 0.4-1.0 In, Isd 1.5-10 Ir, Ii 2-15 In, Ig 0.2-1 In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL 489, CSA C22.2 No.5, IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated frequency\u003c\/th\u003e\n\u003ctd\u003eAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric Susol UL MCCB catalog C01081-17 (2026-07), p. 54-56, 66-74, 85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-NG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-NG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-NG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-NG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-NG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-NG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-NG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-NG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-NG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-NG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-NG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-NG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-NG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-NG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-NG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-NG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-NG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-NG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-NG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-NG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-NG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-NG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-NG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-NG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-NG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-NG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-NG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-NG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-NG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-NG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-NG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-NG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-NG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-NG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-NG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-NG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-NG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-NG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-NG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-NG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-NG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-NG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-NG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-NG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-NG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-NG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-NG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-NG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: N (Normal) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AG7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AG7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AG7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AG7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AG7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AG7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: G - Ground fault, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE0-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE0-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE0-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE0-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 0 - Self power, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE5-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE5-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE5-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE5-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 5 - Self power, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AE7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AE7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AE7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AE7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AE7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AE7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: E - Ground fault\/ext. CT, no comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-AX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-AX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-AX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-AX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-AX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-AX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: A (Ammeter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-PX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-PX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-PX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-PX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-PX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-PX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: P (Power meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SC7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: C - Ground fault + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX1-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX1-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX1-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX1-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 1 - AC\/DC 100-250 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX2-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX2-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX2-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX2-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 2 - DC 24-60 V, 60 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX6-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX6-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX6-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX6-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 6 - AC\/DC 100-250 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX7-400A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX7-600A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX7-630A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-N-SX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: N, 35 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-NT-SX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: NT, 35 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-H-SX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: H, 65 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-HT-SX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: HT, 65 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-L-SX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L, 100 kA at 480 V, 80% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTS800-LT-SX7-800A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: LT, 100 kA at 480 V, 100% rated | Trip relay: S (Super meter) | Protection\/comm.: X - Ground fault\/ext. CT + comm. | Control power: 7 - DC 24-60 V, 50 Hz | Rated current In: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67521962967330,"sku":"UTS800-N-NG0-400A-3P-UL","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-susol-uts800-ul-mccb.jpg?v=1791954616","url":"https:\/\/prosourcemro.com\/products\/ls-electric-susol-uts800-ul-mccb","provider":"ProSource MRO","version":"1.0","type":"link"}