{"product_id":"ls-electric-susol-vcs-vc-12-vacuum-contactor-12kv","title":"LS Electric Susol VCS Vacuum Contactor (VC-12, 12kV 400A)","description":"\u003cp class=\"ps-intro\"\u003eLS Electric Susol VC-12 three-phase 12 kV, 400 A vacuum contactors in fixed, external draw-out and power-fuse combination versions for motors up to 6,000 kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFixed (Z), external screw draw-out (K) and PF-combination external draw-out (B) versions\u003c\/li\u003e\n\u003cli\u003eContinuous-excitation (E) or mechanically latched (L) operating mechanism\u003c\/li\u003e\n\u003cli\u003eSwitches motors up to 6,000 kW, transformers up to 8,000 kVA and capacitors up to 4,000 kVA\u003c\/li\u003e\n\u003cli\u003eFuse checker, earthing-switch truck, DIN fuse clips and accessories selected by order-code suffix\u003c\/li\u003e\n\u003cli\u003eCertified to IEC 62271-106\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated breaking current\u003c\/th\u003e\n\u003ctd\u003e4 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort-time current\u003c\/th\u003e\n\u003ctd\u003e2.4 kA-30 s, 4 kA-10 s, 6 kA-2 s, 6.3 kA-4 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching frequency (AC4)\u003c\/th\u003e\n\u003ctd\u003eE: 1,200\/h; L: 300\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpulse \/ power-frequency withstand\u003c\/th\u003e\n\u003ctd\u003e75 kV \/ 42 kV (1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary contacts\u003c\/th\u003e\n\u003ctd\u003eFixed: E 3a3b, L 2a2b; draw-out: 2a2b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003eIEC 62271-106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric Susol VCS catalog C05061-09 (2025-10), p. 11, 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44EED1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Continuous excitation | Control voltage: DC 110 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44EED2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Continuous excitation | Control voltage: DC 220 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44EED3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Continuous excitation | Control voltage: DC 125 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44EEA1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Continuous excitation | Control voltage: AC 110 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44EEA2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Continuous excitation | Control voltage: AC 220 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44EEA3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Continuous excitation | Control voltage: AC 125 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44LED1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44LED2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44LED3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44LEA1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44LEA2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12Z-44LEA3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: Fixed | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Weight: 30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44EED1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Continuous excitation | Control voltage: DC 110 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44EED2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Continuous excitation | Control voltage: DC 220 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44EED3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Continuous excitation | Control voltage: DC 125 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44EEA1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Continuous excitation | Control voltage: AC 110 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44EEA2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Continuous excitation | Control voltage: AC 220 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44EEA3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Continuous excitation | Control voltage: AC 125 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44LED1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44LED2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44LED3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44LEA1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44LEA2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12K-44LEA3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: External draw-out (screw) | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44EED1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Continuous excitation | Control voltage: DC 110 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44EED2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Continuous excitation | Control voltage: DC 220 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44EED3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Continuous excitation | Control voltage: DC 125 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44EEA1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Continuous excitation | Control voltage: AC 110 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44EEA2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Continuous excitation | Control voltage: AC 220 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44EEA3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Continuous excitation | Control voltage: AC 125 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44LED1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Latched (mechanical latch) | Control voltage: DC 110 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44LED2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Latched (mechanical latch) | Control voltage: DC 220 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44LED3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Latched (mechanical latch) | Control voltage: DC 125 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44LEA1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Latched (mechanical latch) | Control voltage: AC 110 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44LEA2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Latched (mechanical latch) | Control voltage: AC 220 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVC-12B-44LEA3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection type: PF combination external draw-out | Operating method: Latched (mechanical latch) | Control voltage: AC 125 V | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67521972896034,"sku":"VC-12Z-44EED1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-susol-vcs-vc-12-vacuum-contactor-12kv.jpg?v=1791954616","url":"https:\/\/prosourcemro.com\/products\/ls-electric-susol-vcs-vc-12-vacuum-contactor-12kv","provider":"ProSource MRO","version":"1.0","type":"link"}