{"product_id":"ls-electric-ts100hi-susol-smart-mccb-high-85ka-415v","title":"LS Electric TS100Hi Susol Smart MCCB (High, 85kA @ 415V)","description":"\u003cp class=\"ps-intro\"\u003eLS ELECTRIC Susol Smart MCCB TS100Hi family.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e100AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity Icu\u003c\/th\u003e\n\u003ctd\u003e85kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETSi-40A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETSi, 3-pole | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETSi-40A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETSi, 4-pole (L) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETSi-40A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETSi, 4-pole (R) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETMi-40A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETMi, 3-pole | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETMi-40A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETMi, 4-pole (L) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETMi-40A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETMi, 4-pole (R) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETHi-40A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETHi, 3-pole | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETHi-40A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETHi, 4-pole (L) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETHi-40A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETHi, 4-pole (R) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETLi-40A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETLi, 3-pole | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETLi-40A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETLi, 4-pole (L) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETLi-40A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 40A ETLi, 4-pole (R) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETSi-100A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETSi, 3-pole | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETSi-100A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETSi, 4-pole (L) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETSi-100A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETSi, 4-pole (R) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETMi-100A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETMi, 3-pole | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETMi-100A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETMi, 4-pole (L) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETMi-100A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETMi, 4-pole (R) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETHi-100A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETHi, 3-pole | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETHi-100A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETHi, 4-pole (L) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETHi-100A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETHi, 4-pole (R) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETLi-100A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETLi, 3-pole | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETLi-100A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETLi, 4-pole (L) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS100Hi-ETLi-100A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS100Hi — 100A ETLi, 4-pole (R) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67396585160994,"sku":"LSE-TS100Hi","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1499.png?v=1790661637","url":"https:\/\/prosourcemro.com\/products\/ls-electric-ts100hi-susol-smart-mccb-high-85ka-415v","provider":"ProSource MRO","version":"1.0","type":"link"}