{"product_id":"ls-electric-ts250n-ftu-susol-mccb-normal-standard-50ka-415v-ftu-125250a","title":"LS Electric TS250N-FTU Susol MCCB (Normal (Standard), 50kA @ 415V, FTU 125~250A)","description":"\u003cp class=\"ps-intro\"\u003eLS ELECTRIC Susol MCCB TS250N-FTU family.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e250AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity Icu\u003c\/th\u003e\n\u003ctd\u003e50kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip unit\u003c\/th\u003e\n\u003ctd\u003eFTU250 (Thermal-Magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip features\u003c\/th\u003e\n\u003ctd\u003eFixed rated current and instantaneous trip (10×In)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-125A-2P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 125A FTU250, 2-pole | Frame: 250AF | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-125A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 125A FTU250, 3-pole | Frame: 250AF | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-125A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 125A FTU250, 4-pole (L) | Frame: 250AF | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-125A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 125A FTU250, 4-pole (R) | Frame: 250AF | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole right (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-160A-2P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 160A FTU250, 2-pole | Frame: 250AF | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-160A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 160A FTU250, 3-pole | Frame: 250AF | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-160A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 160A FTU250, 4-pole (L) | Frame: 250AF | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-160A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 160A FTU250, 4-pole (R) | Frame: 250AF | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole right (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-200A-2P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 200A FTU250, 2-pole | Frame: 250AF | Rated current (In): 200A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-200A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 200A FTU250, 3-pole | Frame: 250AF | Rated current (In): 200A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-200A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 200A FTU250, 4-pole (L) | Frame: 250AF | Rated current (In): 200A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-200A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 200A FTU250, 4-pole (R) | Frame: 250AF | Rated current (In): 200A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole right (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-250A-2P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 250A FTU250, 2-pole | Frame: 250AF | Rated current (In): 250A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-250A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 250A FTU250, 3-pole | Frame: 250AF | Rated current (In): 250A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-250A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 250A FTU250, 4-pole (L) | Frame: 250AF | Rated current (In): 250A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS250N-FTU250-250A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol MCCB TS250N-FTU — 250A FTU250, 4-pole (R) | Frame: 250AF | Rated current (In): 250A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU250 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole right (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67396586209570,"sku":"LSE-TS250N-FTU","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1500_d822975a-fbc4-4382-b0f5-115b12c36533.png?v=1790661668","url":"https:\/\/prosourcemro.com\/products\/ls-electric-ts250n-ftu-susol-mccb-normal-standard-50ka-415v-ftu-125250a","provider":"ProSource MRO","version":"1.0","type":"link"}