{"product_id":"ls-electric-ts630ni-susol-smart-mccb-normal-standard-65ka-415v","title":"LS Electric TS630Ni Susol Smart MCCB (Normal (Standard), 65kA @ 415V)","description":"\u003cp class=\"ps-intro\"\u003eLS ELECTRIC Susol Smart MCCB TS630Ni family.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e630AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity Icu\u003c\/th\u003e\n\u003ctd\u003e65kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETSi-250A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETSi, 3-pole | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETSi-250A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETSi, 4-pole (L) | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETSi-250A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETSi, 4-pole (R) | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETMi-250A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETMi, 3-pole | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETMi-250A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETMi, 4-pole (L) | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETMi-250A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETMi, 4-pole (R) | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETHi-250A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETHi, 3-pole | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETHi-250A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETHi, 4-pole (L) | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETHi-250A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETHi, 4-pole (R) | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETLi-250A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETLi, 3-pole | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETLi-250A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETLi, 4-pole (L) | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETLi-250A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 250A ETLi, 4-pole (R) | Frame: 630AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETSi-400A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETSi, 3-pole | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETSi-400A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETSi, 4-pole (L) | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETSi-400A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETSi, 4-pole (R) | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETMi-400A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETMi, 3-pole | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETMi-400A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETMi, 4-pole (L) | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETMi-400A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETMi, 4-pole (R) | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETHi-400A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETHi, 3-pole | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETHi-400A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETHi, 4-pole (L) | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETHi-400A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETHi, 4-pole (R) | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETLi-400A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETLi, 3-pole | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETLi-400A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETLi, 4-pole (L) | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETLi-400A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 400A ETLi, 4-pole (R) | Frame: 630AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETSi-630A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETSi, 3-pole | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETSi-630A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETSi, 4-pole (L) | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETSi-630A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETSi, 4-pole (R) | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETMi-630A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETMi, 3-pole | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETMi-630A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETMi, 4-pole (L) | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETMi-630A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETMi, 4-pole (R) | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETHi-630A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETHi, 3-pole | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETHi-630A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETHi, 4-pole (L) | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETHi-630A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETHi, 4-pole (R) | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETLi-630A-3P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETLi, 3-pole | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETLi-630A-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETLi, 4-pole (L) | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS630Ni-ETLi-630A-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Smart MCCB TS630Ni — 630A ETLi, 4-pole (R) | Frame: 630AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current\/voltage\/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67396585554210,"sku":"LSE-TS630Ni","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1499_6a78202a-13f4-466b-aa42-a34bf82c543f.png?v=1790661649","url":"https:\/\/prosourcemro.com\/products\/ls-electric-ts630ni-susol-smart-mccb-normal-standard-65ka-415v","provider":"ProSource MRO","version":"1.0","type":"link"}