{"product_id":"ls-electric-utv250-n-atu-ul-susol-beyond-x-mccb-normal-42ka-800v-atu-100250a-ul489","title":"LS Electric UTV250-N-ATU-UL Susol Beyond X MCCB (Normal, 42kA @ 800V, ATU 100~250A, UL489)","description":"\u003cp class=\"ps-intro\"\u003eLS ELECTRIC Susol Beyond X MCCB UTV250-N-ATU-UL family.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eFor renewable energy and high altitude applications\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e250AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e690*\/800\/1000 Vac (* 690V coming soon)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity Icu\u003c\/th\u003e\n\u003ctd\u003e42kA @ 800V AC, 20kA @ 1000V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaker type\u003c\/th\u003e\n\u003ctd\u003eN (Normal, 80% rating; ET\/NT 100% rating versions also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip unit\u003c\/th\u003e\n\u003ctd\u003eATU (Thermal-Magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip features\u003c\/th\u003e\n\u003ctd\u003eAdjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003eUL489 + CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eRenewable energy (Solar PV, Wind), High altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTV250-N-ATU-100A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Beyond X UTV250-N-ATU-UL — 100A ATU, 3-pole | Frame: 250AF | Rated voltage: 690*\/800\/1000 Vac (* 690V coming soon) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET\/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTV250-N-ATU-100A-4P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Beyond X UTV250-N-ATU-UL — 100A ATU, 4-pole | Frame: 250AF | Rated voltage: 690*\/800\/1000 Vac (* 690V coming soon) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET\/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTV250-N-ATU-150A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Beyond X UTV250-N-ATU-UL — 150A ATU, 3-pole | Frame: 250AF | Rated voltage: 690*\/800\/1000 Vac (* 690V coming soon) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET\/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTV250-N-ATU-150A-4P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Beyond X UTV250-N-ATU-UL — 150A ATU, 4-pole | Frame: 250AF | Rated voltage: 690*\/800\/1000 Vac (* 690V coming soon) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET\/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTV250-N-ATU-200A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Beyond X UTV250-N-ATU-UL — 200A ATU, 3-pole | Frame: 250AF | Rated voltage: 690*\/800\/1000 Vac (* 690V coming soon) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET\/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTV250-N-ATU-200A-4P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Beyond X UTV250-N-ATU-UL — 200A ATU, 4-pole | Frame: 250AF | Rated voltage: 690*\/800\/1000 Vac (* 690V coming soon) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET\/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTV250-N-ATU-250A-3P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Beyond X UTV250-N-ATU-UL — 250A ATU, 3-pole | Frame: 250AF | Rated voltage: 690*\/800\/1000 Vac (* 690V coming soon) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET\/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUTV250-N-ATU-250A-4P-UL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSusol Beyond X UTV250-N-ATU-UL — 250A ATU, 4-pole | Frame: 250AF | Rated voltage: 690*\/800\/1000 Vac (* 690V coming soon) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET\/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67396588798242,"sku":"LSE-UTV250-N-ATU-UL","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1501_adca455a-bd52-4096-bea2-8abf841ef4fb.png?v=1790661714","url":"https:\/\/prosourcemro.com\/products\/ls-electric-utv250-n-atu-ul-susol-beyond-x-mccb-normal-42ka-800v-atu-100250a-ul489","provider":"ProSource MRO","version":"1.0","type":"link"}