{"product_id":"ls-electric-xgb-xbe-digital-io-modules","title":"LS Electric XGB XBE Digital I\/O Expansion Modules","description":"\u003cp class=\"ps-intro\"\u003eLS Electric XGB XBE digital I\/O expansion modules add 8 to 32 DC inputs, relay or transistor outputs, or mixed I\/O to XBC\/XEC compact and XBM\/XEM modular main units.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDC 24 V input modules with 8, 16 or 32 points and DC 12\/24 V 16-point XBE-DC16B\u003c\/li\u003e\n\u003cli\u003eRelay output modules 8 or 16 points, 2 A per point, including individual-common XBE-RY08B\u003c\/li\u003e\n\u003cli\u003eNPN sink (TN) and PNP source (TP) transistor output modules, 8\/16\/32 points\u003c\/li\u003e\n\u003cli\u003eMixed I\/O modules XBE-DR16A (8 in \/ 8 relay) and XBE-DN32A (16 in \/ 16 Tr out)\u003c\/li\u003e\n\u003cli\u003eD-type connector variants (...D) of 8\/16-point modules; 32-point modules use 40-pin connectors for Smart Link\u003c\/li\u003e\n\u003cli\u003ePhotocoupler insulation, LED status per point, 20 to 27 mm module width\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eXGB expansion I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation\u003c\/th\u003e\n\u003ctd\u003ePhotocoupler (inputs, Tr outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput response time\u003c\/th\u003e\n\u003ctd\u003e1\/3\/5\/10\/20\/70\/100 ms selectable (default 3 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStatus display\u003c\/th\u003e\n\u003ctd\u003eLED per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible main units\u003c\/th\u003e\n\u003ctd\u003eXBC\/XEC U, H, SU; XBM\/XEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule dimensions\u003c\/th\u003e\n\u003ctd\u003e20 or 27 x 90 mm (W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric XGB Series catalog (2024-07), p. 72-78, 133-134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-DC08A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: DC input | Points: 8 | Rating: DC 24 V, 4 mA | Connection: Terminal block | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-DC16A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: DC input | Points: 16 | Rating: DC 24 V, 4 mA | Connection: Terminal block | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-DC32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: DC input | Points: 32 | Rating: DC 24 V, 4 mA | Connection: 40-pin connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-DC08D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: DC input | Points: 8 | Rating: DC 24 V, 4 mA | Connection: D-type connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-DC16D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: DC input | Points: 16 | Rating: DC 24 V, 4 mA | Connection: D-type connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-DC16B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: DC input | Points: 16 | Rating: DC 12\/24 V, 4\/8 mA | Connection: Terminal block | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-RY08A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Relay output | Points: 8 | Rating: DC 24 V \/ AC 220 V, 2 A | Connection: Terminal block | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-RY08B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Relay output, individual COM | Points: 8 | Rating: DC 24 V \/ AC 220 V, 2 A | Connection: Terminal block | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-RY16A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Relay output | Points: 16 | Rating: DC 24 V \/ AC 220 V, 2 A | Connection: Terminal block | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-RY08D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Relay output | Points: 8 | Rating: DC 24 V \/ AC 220 V, 2 A | Connection: D-type connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-RY16D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Relay output | Points: 16 | Rating: DC 24 V \/ AC 220 V, 2 A | Connection: D-type connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-TN08A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Tr output, sink | Points: 8 | Rating: DC 12\/24 V, 0.5 A\/point | Connection: Terminal block | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-TN16A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Tr output, sink | Points: 16 | Rating: DC 12\/24 V, 0.5 A\/point | Connection: Terminal block | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-TN32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Tr output, sink | Points: 32 | Rating: DC 12\/24 V, 0.2 A\/point | Connection: 40-pin connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-TN08D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Tr output, sink | Points: 8 | Rating: DC 12\/24 V, 0.5 A\/point | Connection: D-type connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-TN16D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Tr output, sink | Points: 16 | Rating: DC 12\/24 V, 0.5 A\/point | Connection: D-type connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-TP08A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Tr output, source | Points: 8 | Rating: DC 12\/24 V, 0.5 A\/point | Connection: Terminal block | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-TP16A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Tr output, source | Points: 16 | Rating: DC 12\/24 V, 0.5 A\/point | Connection: Terminal block | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-TP32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Tr output, source | Points: 32 | Rating: DC 12\/24 V, 0.2 A\/point | Connection: 40-pin connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-TP08D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Tr output, source | Points: 8 | Rating: DC 12\/24 V, 0.5 A\/point | Connection: D-type connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-TP16D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Tr output, source | Points: 16 | Rating: DC 12\/24 V, 0.5 A\/point | Connection: D-type connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-DR16A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Mixed DC input \/ relay | Points: 8 in \/ 8 out | Rating: DC 24 V in; relay 2 A out | Connection: Terminal block | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-DN32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Mixed DC input \/ Tr sink | Points: 16 in \/ 16 out | Rating: DC 24 V in; DC 12\/24 V 0.2 A out | Connection: 40-pin connector | Status: Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-AC08A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: AC input | Points: 8 | Rating: AC input | Connection: Terminal block | Status: Legacy code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67522190541090,"sku":"XBE-DC08A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-xgb-xbe-digital-io-modules.jpg?v=1791979468","url":"https:\/\/prosourcemro.com\/products\/ls-electric-xgb-xbe-digital-io-modules","provider":"ProSource MRO","version":"1.0","type":"link"}