{"product_id":"ls-electric-xgt-safety-plc-modules","title":"LS Electric XGT Safety PLC Modules (Safety CPU, Safety I\/O, Power)","description":"\u003cp class=\"ps-intro\"\u003eLS Electric XGT integrated Safety PLC modules combine an XGI-SCPU1 safety CPU on the XGT main base with SIL3 \/ PL e safety I\/O modules connected over RAPIEnet+ remote smart expansion.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eXGI-SCPU1 safety CPU runs standard and safety programs in one XG5000 project alongside XGI-CPUUN, XGI-CPUZ3\/5\/7 or XGC-CPUX7\u003c\/li\u003e\n\u003cli\u003eControls up to 128 safety I\/O modules per CPU; up to 8 modules per XEL-BSSRT remote adapter\u003c\/li\u003e\n\u003cli\u003eSafety input, output and mixed I\/O modules with 1oo1 (PL d, Cat. 2) or 1oo2 dual-channel (PL e, Cat. 4) modes\u003c\/li\u003e\n\u003cli\u003eConfigurable test pulse outputs, input on\/off delay filters and discrepancy time monitoring\u003c\/li\u003e\n\u003cli\u003eXGP-SAC24 SELV power module for the main base and XBP-SDC42 safety power module for remote stations\u003c\/li\u003e\n\u003cli\u003eCertified to SIL3 (IEC 61508), Maximum SIL3 (IEC 62061) and PL e Cat. 4 (ISO 13849-1); 20-year lifetime, no proof test\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety standards\u003c\/th\u003e\n\u003ctd\u003eSIL3 (IEC 61508), Max. SIL3 (IEC 62061), PL e Cat. 4 (ISO 13849-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSubsystem type\u003c\/th\u003e\n\u003ctd\u003eType B (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSFF\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 99.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLifetime\u003c\/th\u003e\n\u003ctd\u003e20 years, no proof test required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety network\u003c\/th\u003e\n\u003ctd\u003eRAPIEnet+ smart expansion via XGL-EFMTB \/ XEL-BSSRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible standard CPUs\u003c\/th\u003e\n\u003ctd\u003eXGI-CPUUN, XGI-CPUZ3\/5\/7, XGC-CPUX7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety I\/O signal voltage\u003c\/th\u003e\n\u003ctd\u003eDC 24 V (+20.4 to +28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eOpen type, install in min. IP54 enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric Safety PLC catalog (2025-11), p. 6-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-SCPU1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Safety CPU | Function: Safety CPU, 512 KB program, ladder | I\/O points: 1,024 (max.) | Installed on: XGT main base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGP-SAC24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: SELV power supply | Function: AC 220 V in, DC 5 V 10 A out | I\/O points: None | Installed on: XGT main base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBP-SDC42\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Safety power module | Function: DC 24 V in; SYS 5 V 1 A, I\/O 24 V 7 A | I\/O points: None | Installed on: Remote station (XEL-BSSRT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-SDC08D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Safety digital input | Function: 8 DC 24 V inputs, 8 test pulse outputs | I\/O points: 8 in | Installed on: Remote station (XEL-BSSRT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-STP08D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Safety digital output | Function: 8 PNP outputs, 0.3 A\/point | I\/O points: 8 out | Installed on: Remote station (XEL-BSSRT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXBE-SDP06D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule type: Safety digital I\/O | Function: 4 inputs + 2 PNP outputs 0.3 A\/point | I\/O points: 4 in \/ 2 out | Installed on: Remote station (XEL-BSSRT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67522179399970,"sku":"XGI-SCPU1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-xgt-safety-plc-modules.jpg?v=1791979489","url":"https:\/\/prosourcemro.com\/products\/ls-electric-xgt-safety-plc-modules","provider":"ProSource MRO","version":"1.0","type":"link"}