{"product_id":"ls-electric-xgt-xgi-digital-input-modules","title":"LS Electric XGT XGI Digital Input Modules (DC 24 V \/ AC)","description":"\u003cp class=\"ps-intro\"\u003eLS Electric XGT XGI- digital input modules provide 8 to 64 DC 24 V sink\/source or AC 110\/220 V inputs for XGK, XGI and XGR systems, including a wire-break diagnostic input module.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDC 24 V inputs in 8, 16, 32 and 64 points; A types sink\/source, B types source\u003c\/li\u003e\n\u003cli\u003eAC 110 V (16 points) and AC 220 V (8 points, common or isolated commons) input modules\u003c\/li\u003e\n\u003cli\u003eInput filter selectable 1\/3\/5\/10\/20\/70\/100 ms by I\/O parameter (DC models, default 3 ms)\u003c\/li\u003e\n\u003cli\u003eXGI-D21D diagnostic input detects wire breaks via 10 kohm resistor, with DIAG LEDs and internal flags\u003c\/li\u003e\n\u003cli\u003ePhotocoupler isolation, removable terminal blocks or connectors for easy maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003ePhotocoupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC ON \/ OFF level\u003c\/th\u003e\n\u003ctd\u003eDC 19 V \/ 3 mA min. ; DC 11 V \/ 1.7 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC response time\u003c\/th\u003e\n\u003ctd\u003eOFF to ON 15 ms, ON to OFF 25 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnectors\u003c\/th\u003e\n\u003ctd\u003e40-pin connector types sold without mating connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible CPUs\u003c\/th\u003e\n\u003ctd\u003eXGK, XGI, XGR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration \/ shock\u003c\/th\u003e\n\u003ctd\u003eIEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric XGT Series catalog (2026-07), p. 17, 25-28, 148\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-D21A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eInput voltage: DC 24 V | Points: 8 | Input type: Sink\/Source | Common: 8 pt\/COM | Rated input current: 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-D21D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eInput voltage: DC 24 V | Points: 8 | Input type: Sink\/Source, wire-break diag | Common: 8 pt\/COM | Rated input current: Approx. 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-D22A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eInput voltage: DC 24 V | Points: 16 | Input type: Sink\/Source | Common: 16 pt\/COM | Rated input current: 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-D22B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eInput voltage: DC 24 V | Points: 16 | Input type: Source | Common: 16 pt\/COM | Rated input current: 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-D24A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eInput voltage: DC 24 V | Points: 32 | Input type: Sink\/Source | Common: 32 pt\/COM | Rated input current: 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-D24B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eInput voltage: DC 24 V | Points: 32 | Input type: Source | Common: 32 pt\/COM | Rated input current: 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-D28A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eInput voltage: DC 24 V | Points: 64 | Input type: Sink\/Source | Common: 32 pt\/COM | Rated input current: 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-D28B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eInput voltage: DC 24 V | Points: 64 | Input type: Source | Common: 32 pt\/COM | Rated input current: 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-A12A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eInput voltage: AC 100-120 V | Points: 16 | Input type: AC input | Common: 16 pt\/COM | Rated input current: 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-A21A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eInput voltage: AC 100-240 V | Points: 8 | Input type: AC input | Common: 8 pt\/COM | Rated input current: 17 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXGI-A21C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eInput voltage: AC 100-240 V | Points: 8 | Input type: AC input, isolated COM | Common: 1 pt\/COM | Rated input current: 17 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67522189263138,"sku":"XGI-D21A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-xgt-xgi-digital-input-modules.jpg?v=1791979489","url":"https:\/\/prosourcemro.com\/products\/ls-electric-xgt-xgi-digital-input-modules","provider":"ProSource MRO","version":"1.0","type":"link"}