{"product_id":"mitsubishi-electric-cd-802-heavy-duty-magnetic-contactor-2-pole-800a-ith-400kw-at-380-440v","title":"Mitsubishi Electric - CD-802 Heavy Duty Magnetic Contactor (2-pole, 800A Ith, 400kW at 380-440V)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series CD-802 heavy duty magnetic contactor of European construction, suited to control of cranes, rolling mills and similar heavy industrial machinery. 2-pole main circuit, rated insulation voltage 660V at 50\/60Hz, rated operational current 800A at 200-220V, 750A at 380-440V, 600A at 500-550V under AC-3 class and 800A at 200-220V, 800A at 380-440V, 800A at 500-550V under AC-2 class, rated capacity 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V under AC-3 class, rated carrying current 800A.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eMounting dimensions are modularised in integer multiples of 50mm for easy combination into prefabricated panels, and the LI type auxiliary contact is common across the whole range and can be changed between a contact and b contact on a single unit\u003c\/li\u003e\n\u003cli\u003eAuxiliary contacts 4 poles maximum, 2a2b standard\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 1200 operations\/h\u003c\/li\u003e\n\u003cli\u003eOperating circuit accepts DC100V, DC110V, DC200V and DC220V, and the RF variant adds a built-in rectifier for AC100V, AC110V, AC200V and AC220V sources, with a tolerance of 85 to 110 percent of rated operating voltage\u003c\/li\u003e\n\u003cli\u003eReversing type is available as CD-2X802\u003c\/li\u003e\n\u003cli\u003eCompliant with JEM1038\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eHeavy duty magnetic contactor, European style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eCD-802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Voltage Tolerance\u003c\/th\u003e\n\u003ctd\u003e85 to 110 percent of rated operating voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Insulation Voltage\u003c\/th\u003e\n\u003ctd\u003e660V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current AC-3 Class\u003c\/th\u003e\n\u003ctd\u003e800A at 200-220V, 750A at 380-440V, 600A at 500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current AC-2 Class\u003c\/th\u003e\n\u003ctd\u003e800A at 200-220V, 800A at 380-440V, 800A at 500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current AC-1 Class\u003c\/th\u003e\n\u003ctd\u003e800A at 550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Capacity AC-3 Class\u003c\/th\u003e\n\u003ctd\u003e200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Capacity AC-2 Class\u003c\/th\u003e\n\u003ctd\u003e200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Carrying Current Ith\u003c\/th\u003e\n\u003ctd\u003e800A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-802 DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-802 heavy duty contactor, DC100V operating circuit, non-reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Non-reversing | Rectifier: DC source with DC operation | Operating Circuit Voltage: DC100V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 1.2A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-2X802 DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-2X802 heavy duty contactor, DC100V operating circuit, reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Reversing | Rectifier: DC source with DC operation | Operating Circuit Voltage: DC100V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 1.2A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-802 DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-802 heavy duty contactor, DC110V operating circuit, non-reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Non-reversing | Rectifier: DC source with DC operation | Operating Circuit Voltage: DC110V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 1.1A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-2X802 DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-2X802 heavy duty contactor, DC110V operating circuit, reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Reversing | Rectifier: DC source with DC operation | Operating Circuit Voltage: DC110V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 1.1A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-802 DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-802 heavy duty contactor, DC200V operating circuit, non-reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Non-reversing | Rectifier: DC source with DC operation | Operating Circuit Voltage: DC200V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 0.6A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-2X802 DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-2X802 heavy duty contactor, DC200V operating circuit, reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Reversing | Rectifier: DC source with DC operation | Operating Circuit Voltage: DC200V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 0.6A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-802 DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-802 heavy duty contactor, DC220V operating circuit, non-reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Non-reversing | Rectifier: DC source with DC operation | Operating Circuit Voltage: DC220V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 0.55A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-2X802 DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-2X802 heavy duty contactor, DC220V operating circuit, reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Reversing | Rectifier: DC source with DC operation | Operating Circuit Voltage: DC220V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 0.55A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-802-RF AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-802-RF heavy duty contactor, AC100V operating circuit, non-reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Non-reversing | Rectifier: AC source with DC operation, built-in rectifier | Operating Circuit Voltage: AC100V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 1.2A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-2X802-RF AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-2X802-RF heavy duty contactor, AC100V operating circuit, reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Reversing | Rectifier: AC source with DC operation, built-in rectifier | Operating Circuit Voltage: AC100V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 1.2A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-802-RF AC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-802-RF heavy duty contactor, AC110V operating circuit, non-reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Non-reversing | Rectifier: AC source with DC operation, built-in rectifier | Operating Circuit Voltage: AC110V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 1.1A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-2X802-RF AC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-2X802-RF heavy duty contactor, AC110V operating circuit, reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Reversing | Rectifier: AC source with DC operation, built-in rectifier | Operating Circuit Voltage: AC110V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 1.1A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-802-RF AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-802-RF heavy duty contactor, AC200V operating circuit, non-reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Non-reversing | Rectifier: AC source with DC operation, built-in rectifier | Operating Circuit Voltage: AC200V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 0.6A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-2X802-RF AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-2X802-RF heavy duty contactor, AC200V operating circuit, reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Reversing | Rectifier: AC source with DC operation, built-in rectifier | Operating Circuit Voltage: AC200V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 0.6A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-802-RF AC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-802-RF heavy duty contactor, AC220V operating circuit, non-reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Non-reversing | Rectifier: AC source with DC operation, built-in rectifier | Operating Circuit Voltage: AC220V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 0.55A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCD-2X802-RF AC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCD-2X802-RF heavy duty contactor, AC220V operating circuit, reversing | Type: Heavy duty magnetic contactor, European style | Frame: CD-802 | Poles: 2-pole | Configuration: Reversing | Rectifier: AC source with DC operation, built-in rectifier | Operating Circuit Voltage: AC220V | Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage | Operating Circuit Current: 0.55A at 20 degrees C cold with rated voltage applied | Rated Insulation Voltage: 660V | Rated Frequency: 50\/60Hz | Rated Operational Current AC-3 Class: 800A at 200-220V, 750A at 380-440V, 600A at 500-550V | Rated Operational Current AC-2 Class: 800A at 200-220V, 800A at 380-440V, 800A at 500-550V | Rated Operational Current AC-1 Class: 800A at 550V | Rated Capacity AC-3 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Capacity AC-2 Class: 200kW at 200-220V, 400kW at 380-440V, 400kW at 500-550V | Rated Carrying Current Ith: 800A | Switching Frequency: 1200 operations\/h | Aux Contact: 4 poles maximum, 2a2b standard | Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A | Standards: JEM1038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396649484578,"sku":"MEL-CD-802","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-cd-1_01f54886-d00a-4174-a25e-b6c7e90a667a.png?v=1790663074","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-cd-802-heavy-duty-magnetic-contactor-2-pole-800a-ith-400kw-at-380-440v","provider":"ProSource MRO","version":"1.0","type":"link"}