{"product_id":"mitsubishi-electric-du-n180-dc-magnetic-contactor-ac-operated-2a1b-main-35kw-at-dc220v","title":"Mitsubishi Electric - DU-N180 DC Magnetic Contactor (AC Operated, 2a1b Main, 35kW at DC220V)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series DU-N180 DC magnetic contactor for DC motor control and general DC circuit switching at DC440V and below, including variable speed drive applications and dynamic braking.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eAC operated coil with 2a1b main contacts and 2a2b twin auxiliary contacts applicable down to DC20V 5mA\u003c\/li\u003e\n\u003cli\u003eRated capacity 22kW at DC110V, 35kW at DC220V, 45kW at DC440V in two-pole series connection, open thermal current 270A, rated insulation voltage 660V, coil power consumption 4.2W\u003c\/li\u003e\n\u003cli\u003eReversing type DU-2XN180 is available on the same frame\u003c\/li\u003e\n\u003cli\u003eAuxiliary contact units UN-AX and charged-part protection cover units UN-CZ from the MS-N series are applicable\u003c\/li\u003e\n\u003cli\u003eMechanical durability 2,500,000 operations, electrical durability 500,000 operations at 1200 operations per hour\u003c\/li\u003e\n\u003cli\u003eCompliant with JEM1038 DC2 and DC4 class and JIS C8201-5-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eDC magnetic contactor for DC440V or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eDU-N180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eAC operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Contact\u003c\/th\u003e\n\u003ctd\u003e2a1b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e2a2b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking Capacity 2-Pole Series\u003c\/th\u003e\n\u003ctd\u003e960A at DC110V, 720A at DC220V, 480A at DC440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClosing Current Capacity\u003c\/th\u003e\n\u003ctd\u003e960A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOpen Thermal Current Ith\u003c\/th\u003e\n\u003ctd\u003e270A on a contact, 260A on b contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Insulation Voltage\u003c\/th\u003e\n\u003ctd\u003e660V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Power Consumption\u003c\/th\u003e\n\u003ctd\u003e4.2W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching Frequency\u003c\/th\u003e\n\u003ctd\u003e1200 operations\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDurability\u003c\/th\u003e\n\u003ctd\u003eMechanical 2,500,000 operations, Electrical 500,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-N180 AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-N180 DC contactor, AC48V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC48V | Coil Rating: 48-50V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-2XN180 AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-2XN180 DC contactor, AC48V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC48V | Coil Rating: 48-50V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-N180 AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-N180 DC contactor, AC100V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC100V | Coil Rating: 100-127V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-2XN180 AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-2XN180 DC contactor, AC100V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC100V | Coil Rating: 100-127V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-N180 AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-N180 DC contactor, AC200V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC200V | Coil Rating: 200-240V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-2XN180 AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-2XN180 DC contactor, AC200V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC200V | Coil Rating: 200-240V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-N180 AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-N180 DC contactor, AC300V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC300V | Coil Rating: 260-350V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-2XN180 AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-2XN180 DC contactor, AC300V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC300V | Coil Rating: 260-350V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-N180 AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-N180 DC contactor, AC400V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC400V | Coil Rating: 380-440V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-2XN180 AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-2XN180 DC contactor, AC400V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC400V | Coil Rating: 380-440V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-N180 AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-N180 DC contactor, AC500V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC500V | Coil Rating: 460-550V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDU-2XN180 AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDU-2XN180 DC contactor, AC500V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC500V | Coil Rating: 460-550V 50\/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396647256354,"sku":"MEL-DU-N180","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-du-n30-1_31605e1d-ec16-4bac-b656-bee0da3a4ed4.png?v=1790663013","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-du-n180-dc-magnetic-contactor-ac-operated-2a1b-main-35kw-at-dc220v","provider":"ProSource MRO","version":"1.0","type":"link"}