{"product_id":"mitsubishi-electric-dud-n260-dc-magnetic-contactor-dc-operated-2a-main-45kw-at-dc220v","title":"Mitsubishi Electric - DUD-N260 DC Magnetic Contactor (DC Operated, 2a Main, 45kW at DC220V)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series DUD-N260 DC magnetic contactor for DC motor control and general DC circuit switching at DC440V and below, including variable speed drive applications and dynamic braking.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDC operated coil with 2a main contacts and 2a2b twin auxiliary contacts applicable down to DC20V 5mA\u003c\/li\u003e\n\u003cli\u003eRated capacity 30kW at DC110V, 45kW at DC220V, 55kW at DC440V in two-pole series connection, open thermal current 360A, rated insulation voltage 660V, coil power consumption 55W\u003c\/li\u003e\n\u003cli\u003eReversing type DUD-2XN260 is available on the same frame\u003c\/li\u003e\n\u003cli\u003eAuxiliary contact units UN-AX and charged-part protection cover units UN-CZ from the MS-N series are applicable\u003c\/li\u003e\n\u003cli\u003eMechanical durability 2,500,000 operations, electrical durability 500,000 operations at 1200 operations per hour\u003c\/li\u003e\n\u003cli\u003eCompliant with JEM1038 DC2 and DC4 class and JIS C8201-5-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eDC magnetic contactor for DC440V or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eDU-N260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eDC operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Contact\u003c\/th\u003e\n\u003ctd\u003e2a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e2a2b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking Capacity 2-Pole Series\u003c\/th\u003e\n\u003ctd\u003e1400A at DC110V, 1040A at DC220V, 700A at DC440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClosing Current Capacity\u003c\/th\u003e\n\u003ctd\u003e1400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOpen Thermal Current Ith\u003c\/th\u003e\n\u003ctd\u003e360A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Insulation Voltage\u003c\/th\u003e\n\u003ctd\u003e660V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Power Consumption\u003c\/th\u003e\n\u003ctd\u003e55W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching Frequency\u003c\/th\u003e\n\u003ctd\u003e1200 operations\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDurability\u003c\/th\u003e\n\u003ctd\u003eMechanical 2,500,000 operations, Electrical 500,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-N260 DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-N260 DC contactor, DC12V coil, 2a main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Non-reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC12V | Coil Rating: DC12V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-2XN260 DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-2XN260 DC contactor, DC12V coil, 2a main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC12V | Coil Rating: DC12V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-N260 DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-N260 DC contactor, DC24V coil, 2a main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Non-reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC24V | Coil Rating: DC24V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-2XN260 DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-2XN260 DC contactor, DC24V coil, 2a main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC24V | Coil Rating: DC24V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-N260 DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-N260 DC contactor, DC48V coil, 2a main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Non-reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC48V | Coil Rating: DC48V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-2XN260 DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-2XN260 DC contactor, DC48V coil, 2a main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC48V | Coil Rating: DC48V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-N260 DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-N260 DC contactor, DC100V coil, 2a main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Non-reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC100V | Coil Rating: DC100V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-2XN260 DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-2XN260 DC contactor, DC100V coil, 2a main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC100V | Coil Rating: DC100V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-N260 DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-N260 DC contactor, DC110V coil, 2a main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Non-reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC110V | Coil Rating: DC110V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-2XN260 DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-2XN260 DC contactor, DC110V coil, 2a main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC110V | Coil Rating: DC110V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-N260 DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-N260 DC contactor, DC125V coil, 2a main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Non-reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC125V | Coil Rating: DC120-125V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-2XN260 DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-2XN260 DC contactor, DC125V coil, 2a main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC125V | Coil Rating: DC120-125V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-N260 DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-N260 DC contactor, DC200V coil, 2a main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Non-reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC200V | Coil Rating: DC200V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-2XN260 DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-2XN260 DC contactor, DC200V coil, 2a main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC200V | Coil Rating: DC200V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-N260 DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-N260 DC contactor, DC220V coil, 2a main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Non-reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC220V | Coil Rating: DC220V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDUD-2XN260 DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDUD-2XN260 DC contactor, DC220V coil, 2a main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N260 | Configuration: Reversing | Operation: DC operated | Main Contact: 2a | Coil Designation: DC220V | Coil Rating: DC220V | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 30kW at DC110V, 45kW at DC220V, 55kW at DC440V | Rated Current General DC Motor 2-Pole Series: 350A at DC110V, 260A at DC220V, 175A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 360A at DC110V, 360A at DC220V, 360A at DC440V | Breaking Capacity 2-Pole Series: 1400A at DC110V, 1040A at DC220V, 700A at DC440V | Closing Current Capacity: 1400A | Open Thermal Current Ith: 360A | Rated Insulation Voltage: 660V | Coil Power Consumption: 55W | Switching Frequency: 1200 operations\/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396647354658,"sku":"MEL-DUD-N260","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-du-n30-1_4d0db4fb-81ff-4ea4-8231-dd2944f8ce8d.png?v=1790663016","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-dud-n260-dc-magnetic-contactor-dc-operated-2a-main-45kw-at-dc220v","provider":"ProSource MRO","version":"1.0","type":"link"}