{"product_id":"mitsubishi-electric-fr-a800-fr-a8avp-high-power-factor-changeover-components","title":"Mitsubishi Electric FR-A8AVP Changeover Components for FR-A842","description":"\u003cp class=\"ps-intro\"\u003eDedicated peripheral components that, with the FR-A8AVP plug-in option, let an FR-A842 separated-converter inverter operate as a high power factor converter.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eChangeover between inverter and high power factor converter by FR-A8AVP plus parameter setting\u003c\/li\u003e\n\u003cli\u003eConverter mode: input power factor 0.99 or more (100% load), greatly suppressed harmonics\u003c\/li\u003e\n\u003cli\u003eKit: phase detection transformer box, filter reactor, PWM reactor, filter capacitor, inrush protection parts\u003c\/li\u003e\n\u003cli\u003eConverter rated output 375-595 kW (315K-500K), overload 150% 60 s\u003c\/li\u003e\n\u003cli\u003eCan be changed back to inverter operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eFR-A8AVP changeover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplicable inverter\u003c\/th\u003e\n\u003ctd\u003eFR-A842-315K to 500K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage class\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConverter input\u003c\/th\u003e\n\u003ctd\u003eThree-phase 380-500 V 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput power factor\u003c\/th\u003e\n\u003ctd\u003e0.99 or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eForced air (converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eMitsubishi Electric FR-A800 catalogue L(NA)06075ENG-J, p. 142, 143, 144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8VPB-H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Phase detection transformer box | Use with: FR-A842-315K to 500K | Capacity required: 315-500 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL1-H315K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated filter reactor | Use with: FR-A842-315K | Capacity required: 315 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL1-H355K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated filter reactor | Use with: FR-A842-355K | Capacity required: 355 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL1-H400K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated filter reactor | Use with: FR-A842-400K | Capacity required: 400 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL1-H450K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated filter reactor | Use with: FR-A842-450K | Capacity required: 450 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL1-H500K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated filter reactor | Use with: FR-A842-500K | Capacity required: 500 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL2-H315K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated reactor for PWM control | Use with: FR-A842-315K | Capacity required: 315 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL2-H355K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated reactor for PWM control | Use with: FR-A842-355K | Capacity required: 355 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL2-H400K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated reactor for PWM control | Use with: FR-A842-400K | Capacity required: 400 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL2-H450K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated reactor for PWM control | Use with: FR-A842-450K | Capacity required: 450 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL2-H500K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated reactor for PWM control | Use with: FR-A842-500K | Capacity required: 500 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BC-H400K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated filter capacitor | Use with: FR-A842-315K to 400K | Capacity required: 315-400 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BC-H500K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Dedicated filter capacitor | Use with: FR-A842-450K, 500K | Capacity required: 450-500 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8MC-H355K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Inrush current protection parts | Use with: FR-A842-315K, 355K | Capacity required: 315-355 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8MC-H500K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eComponent: Inrush current protection parts | Use with: FR-A842-400K to 500K | Capacity required: 400-500 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLegacy code (series name only; order full model) | Component: see FR-A8BC-H400K \/ -H500K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLegacy code (series name only; order full model) | Component: see FR-A8BL1-H315K to -H500K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLegacy code (series name only; order full model) | Component: see FR-A8BL2-H315K to -H500K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8MC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLegacy code (series name only; order full model) | Component: see FR-A8MC-H355K \/ -H500K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8VPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLegacy code (series name only; order full model) | Component: see FR-A8VPB-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67534145126690,"sku":"FR-A8VPB-H","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/mitsubishi-electric-fr-a800-fr-a8avp-high-power-factor-changeover-components.jpg?v=1792126723","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-fr-a800-fr-a8avp-high-power-factor-changeover-components","provider":"ProSource MRO","version":"1.0","type":"link"}