{"product_id":"mitsubishi-electric-fr-a800-mt-bsl-mt-bsc-sine-wave-filter","title":"Mitsubishi Electric MT-BSL \/ MT-BSC Sine Wave Filter (75kW or higher)","description":"\u003cp class=\"ps-intro\"\u003eThe MT-BSL reactor and MT-BSC capacitor form a sine wave filter on the inverter output so that motor voltage and current become sinusoidal.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFor FR-A820-03800(75K) \/ FR-A840-02160(75K) or higher and 75 kW or higher motors\u003c\/li\u003e\n\u003cli\u003eLow noise, no surge current and small motor losses for standard motors\u003c\/li\u003e\n\u003cli\u003eRequires Pr.72 = 25 (2.5 kHz carrier), V\/F control and output frequency 60 Hz or lower\u003c\/li\u003e\n\u003cli\u003eUse MT-BSL-(H)[]K-HC reactors when combined with the FR-HC2\u003c\/li\u003e\n\u003cli\u003eSelect so that motor rated current x 1.1 is 90% or less of inverter rated current\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eMT-BSL \/ MT-BSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003ctd\u003eStand-alone option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplicable series\u003c\/th\u003e\n\u003ctd\u003eFR-A800, FR-F800 (75K or higher)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCarrier frequency\u003c\/th\u003e\n\u003ctd\u003e2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003ctd\u003eV\/F control only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eMitsubishi Electric FR-A800 catalogue L(NA)06075ENG-J, p. 171\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor | Voltage: 200 V | Motor capacity: 75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-90K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor | Voltage: 200 V | Motor capacity: 90 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-H75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor | Voltage: 400 V | Motor capacity: 75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-H75K-HC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor (for FR-HC2) | Voltage: 400 V | Motor capacity: 75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-H110K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor | Voltage: 400 V | Motor capacity: 90-110 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-H110K-HC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor (for FR-HC2) | Voltage: 400 V | Motor capacity: 90-110 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-H150K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor | Voltage: 400 V | Motor capacity: 132 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-H150K-HC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor (for FR-HC2) | Voltage: 400 V | Motor capacity: 132 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-H220K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor | Voltage: 400 V | Motor capacity: 160-220 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-H220K-HC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor (for FR-HC2) | Voltage: 400 V | Motor capacity: 160-220 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-H280K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor | Voltage: 400 V | Motor capacity: 250-280 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSL-H280K-HC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Reactor (for FR-HC2) | Voltage: 400 V | Motor capacity: 250-280 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSC-75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Capacitor | Voltage: 200 V | Motor capacity: 75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSC-90K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Capacitor | Voltage: 200 V | Motor capacity: 90 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSC-H75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Capacitor | Voltage: 400 V | Motor capacity: 75 (x1), 132 (x2) kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-BSC-H110K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Capacitor | Voltage: 400 V | Motor capacity: 90-280 (x1 to x3) kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67534145618210,"sku":"MT-BSL-75K","price":0.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-fr-a800-mt-bsl-mt-bsc-sine-wave-filter","provider":"ProSource MRO","version":"1.0","type":"link"}