{"product_id":"mitsubishi-electric-fr-e700-fr-e800-mounting-attachments","title":"Mitsubishi Electric FR-E700 \/ FR-E800 Mounting Attachments","description":"\u003cp class=\"ps-intro\"\u003eIntercompatibility, DIN rail, panel-through and totally enclosed attachments for FR-E700 and FR-E800 compact inverters.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFR-E7AT: mount FR-E700 in FR-A024\/A044 holes; FR-E8AT: mount FR-E800 in FR-E700 holes\u003c\/li\u003e\n\u003cli\u003eFR-UDA01-03 DIN rail attachments for 3.7K or lower; FR-UDA02 also fits 1-phase 0.75K (S: 0.75K\/1.5K)\u003c\/li\u003e\n\u003cli\u003eFR-E7CN \/ FR-E8CN panel-through attachments dissipate about 70% of heat outside the enclosure\u003c\/li\u003e\n\u003cli\u003eFR-E7CV totally enclosed attachment gives IP40-equivalent structure (JEM1030)\u003c\/li\u003e\n\u003cli\u003eAttachment model depends on inverter model and capacity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFor series\u003c\/th\u003e\n\u003ctd\u003eFR-E700, FR-E800 (FR-UDA also FR-D700)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eMitsubishi Electric FR-E700 catalogue L(NA)06051ENG, p. 73, 76-77; Mitsubishi Electric FR-E800 catalogue L(NA)06131ENG, p. 94, 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7AT01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7AT01 | Type: Intercompatibility (FR-A024\/A044) | Applicable inverter: FR-E720 0.1K-0.75K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7AT02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7AT02 | Type: Intercompatibility (FR-A024\/A044) | Applicable inverter: FR-E720 1.5K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7AT03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7AT03 | Type: Intercompatibility (FR-A024\/A044) | Applicable inverter: E720 2.2K\/3.7K; E740 1.5K-3.7K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E8AT03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E8AT03 | Type: Intercompatibility (FR-E700 holes) | Applicable inverter: FR-E820-3.7K (0175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E8AT04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E8AT04 | Type: Intercompatibility (FR-E700 holes) | Applicable inverter: FR-E820S-2.2K (0110)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-UDA01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-UDA01 | Type: DIN rail installation | Applicable inverter: E720\/E820 0.1-0.75K; 1-phase 0.1-0.4K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-UDA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-UDA02 | Type: DIN rail installation | Applicable inverter: E720\/E820 1.5K-2.2K; E840 0.4-1.5K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-UDA03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-UDA03 | Type: DIN rail installation | Applicable inverter: E720\/E820 3.7K; E820S 2.2K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7CN01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7CN01 | Type: Panel through (FR-E700) | Applicable inverter: E720 1.5K\/2.2K; E720S 0.75K\/1.5K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7CN02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7CN02 | Type: Panel through (FR-E700) | Applicable inverter: E720 3.7K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7CN03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7CN03 | Type: Panel through (FR-E700) | Applicable inverter: E720 5.5K\/7.5K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7CN04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7CN04 | Type: Panel through (FR-E700) | Applicable inverter: E740 1.5-3.7K; E720S 2.2K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7CN05\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7CN05 | Type: Panel through (FR-E700) | Applicable inverter: E740 5.5K\/7.5K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7CN06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7CN06 | Type: Panel through (FR-E700) | Applicable inverter: E720 11K\/15K; E740 11K\/15K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E8CN01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E8CN01 | Type: Panel through (FR-E800) | Applicable inverter: E820 1.5K\/2.2K; E820S 1.5K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E8CN02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E8CN02 | Type: Panel through (FR-E800) | Applicable inverter: E820 3.7K; E820S 2.2K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E8CN03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E8CN03 | Type: Panel through (FR-E800) | Applicable inverter: E820 5.5K\/7.5K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E8CN04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E8CN04 | Type: Panel through (FR-E800) | Applicable inverter: E840 1.5K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E8CN05\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E8CN05 | Type: Panel through (FR-E800) | Applicable inverter: E840 2.2K\/3.7K; E860 1.5K\/2.2K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E8CN06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E8CN06 | Type: Panel through (FR-E800) | Applicable inverter: E840 5.5K\/7.5K; E860 3.7K-7.5K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7CV01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7CV01 | Type: Totally enclosed (IP40) | Applicable inverter: FR-E720-0.1K to 0.75K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7CV02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7CV02 | Type: Totally enclosed (IP40) | Applicable inverter: FR-E720-1.5K, 2.2K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7CV03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7CV03 | Type: Totally enclosed (IP40) | Applicable inverter: FR-E720-3.7K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7CV04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7CV04 | Type: Totally enclosed (IP40) | Applicable inverter: FR-E720-5.5K, 7.5K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67534144012578,"sku":"FR-E7AT01","price":0.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-fr-e700-fr-e800-mounting-attachments","provider":"ProSource MRO","version":"1.0","type":"link"}