{"product_id":"mitsubishi-electric-fr-e700-plug-in-options","title":"Mitsubishi Electric FR-E700 \/ FR-E800 Plug-in Options (E kit)","description":"\u003cp class=\"ps-intro\"\u003ePlug-in I\/O, communication and 24VDC input options dedicated to FREQROL-E700 and FR-E800 compact inverters.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eOne plug-in option can be mounted per inverter\u003c\/li\u003e\n\u003cli\u003eE kit includes the option board and its dedicated front cover for standard models\u003c\/li\u003e\n\u003cli\u003eSafety stop (SC) models use the plain FR-A7 board with the FR-A7A E kit cover SC\u003c\/li\u003e\n\u003cli\u003eFR-E7DS \/ FR-E8DS keep I\/O and panel functions alive on 24VDC with main power off\u003c\/li\u003e\n\u003cli\u003eFR-E7TR adds an RS-485 2-port terminal block for easy multi-drop wiring\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFor series\u003c\/th\u003e\n\u003ctd\u003eFREQROL FR-E700 (FR-E8DS: FR-E800)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003ePlug-in, one option per inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eMitsubishi Electric FR-E700 catalogue L(NA)06051ENG, p. 6, 72; Mitsubishi Electric FR-E800 catalogue L(NA)06131ENG, p. 94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7AX E kit\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7AX E kit | Function: 16-bit digital input | For: Standard model | Form: Plug-in option kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7AY E kit\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7AY E kit | Function: Digital output \/ ext. analog output | For: Standard model | Form: Plug-in option kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7AR E kit\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7AR E kit | Function: Relay output (3 contacts) | For: Standard model | Form: Plug-in option kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7NC E kit\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7NC E kit | Function: CC-Link communication | For: Standard model | Form: Plug-in option kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7NL E kit\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7NL E kit | Function: LONWORKS communication | For: Standard model | Form: Plug-in option kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7ND E kit\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7ND E kit | Function: DeviceNet communication | For: Standard model | Form: Plug-in option kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7NP E kit\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7NP E kit | Function: PROFIBUS-DP communication | For: Standard model | Form: Plug-in option kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7AX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7AX | Function: 16-bit digital input | For: SC model (with cover kit) | Form: Plug-in option board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7AY\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7AY | Function: Digital output \/ ext. analog output | For: SC model (with cover kit) | Form: Plug-in option board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7AR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7AR | Function: Relay output (3 contacts) | For: SC model (with cover kit) | Form: Plug-in option board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7NC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7NC | Function: CC-Link communication | For: SC model (with cover kit) | Form: Plug-in option board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7NL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7NL | Function: LONWORKS communication | For: SC model (with cover kit) | Form: Plug-in option board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7ND\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7ND | Function: DeviceNet communication | For: SC model (with cover kit) | Form: Plug-in option board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7NP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7NP | Function: PROFIBUS-DP communication | For: SC model (with cover kit) | Form: Plug-in option board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A7A E kit cover SC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-A7A E kit cover SC | Function: Dedicated front cover for SC models | For: SC model | Form: Cover kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7DS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7DS | Function: 24VDC external power input | For: FR-E700 SC model | Form: Plug-in option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E7TR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E7TR | Function: RS-485 2-port terminal block | For: Standard \/ -NE model | Form: Control terminal option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E8DS E kit\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: FR-E8DS E kit | Function: 24VDC external power input | For: FR-E800 (all models) | Form: Plug-in option kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67534143947042,"sku":"FR-A7AX E kit","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/mitsubishi-electric-fr-e700-plug-in-options.jpg?v=1792126723","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-fr-e700-plug-in-options","provider":"ProSource MRO","version":"1.0","type":"link"}