{"product_id":"mitsubishi-electric-fr-e840-compact-inverter-3-phase-400v-0-4-22kw-safety-communication-sil3-ple","title":"Mitsubishi Electric FR-E840 Compact Inverter (3-Phase 400V, 0.4–22kW, Safety Communication SIL3\/PLe)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric FR-E840 safety-communication-spec compact inverter, 3-phase 380–480V class, 0.4–22kW, with Ethernet and SIL3\/PLe functional safety over network.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDual LD\/ND rating (model name = ND), overload 150% 60s \/ 200% 3s (ND) or 120% 60s \/ 150% 3s (LD) at 50°C, Soft-PWM control, open type IP20\u003c\/li\u003e\n\u003cli\u003eOptional circuit board coating (-60\/-06) available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Logic\u003c\/th\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrake Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailability\u003c\/th\u003e\n\u003ctd\u003eMade-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.4KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.4kW ND, Safety SCEPA | Capacity ND: 0.4 kW (code 0016) | Motor LD: 0.75 kW | Rated Current ND: 1.6 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.1 A (1.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.4KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.4kW ND, Safety SCEPB | Capacity ND: 0.4 kW (code 0016) | Motor LD: 0.75 kW | Rated Current ND: 1.6 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.1 A (1.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.75KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.75kW ND, Safety SCEPA | Capacity ND: 0.75 kW (code 0026) | Motor LD: 1.5 kW | Rated Current ND: 2.6 A (2.2 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.75KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.75kW ND, Safety SCEPB | Capacity ND: 0.75 kW (code 0026) | Motor LD: 1.5 kW | Rated Current ND: 2.6 A (2.2 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-1.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 1.5kW ND, Safety SCEPA | Capacity ND: 1.5 kW (code 0040) | Motor LD: 2.2 kW | Rated Current ND: 4.0 A (3.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 5.5 A (4.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.0 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-1.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 1.5kW ND, Safety SCEPB | Capacity ND: 1.5 kW (code 0040) | Motor LD: 2.2 kW | Rated Current ND: 4.0 A (3.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 5.5 A (4.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.0 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-2.2KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 2.2kW ND, Safety SCEPA | Capacity ND: 2.2 kW (code 0060) | Motor LD: 3.0 kW | Rated Current ND: 6.0 A (5.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.9 A (5.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.6 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-2.2KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 2.2kW ND, Safety SCEPB | Capacity ND: 2.2 kW (code 0060) | Motor LD: 3.0 kW | Rated Current ND: 6.0 A (5.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.9 A (5.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.6 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-3.7KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 3.7kW ND, Safety SCEPA | Capacity ND: 3.7 kW (code 0095) | Motor LD: 5.5 kW | Rated Current ND: 9.5 A (8.7 A at 2kHz+ low-noise PWM) | Rated Current LD: 11.1 A (9.4 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.2 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-3.7KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 3.7kW ND, Safety SCEPB | Capacity ND: 3.7 kW (code 0095) | Motor LD: 5.5 kW | Rated Current ND: 9.5 A (8.7 A at 2kHz+ low-noise PWM) | Rated Current LD: 11.1 A (9.4 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.2 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-5.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 5.5kW ND, Safety SCEPA | Capacity ND: 5.5 kW (code 0120) | Motor LD: 7.5 kW | Rated Current ND: 12.0 A | Rated Current LD: 17.5 A (14.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.1 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-5.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 5.5kW ND, Safety SCEPB | Capacity ND: 5.5 kW (code 0120) | Motor LD: 7.5 kW | Rated Current ND: 12.0 A | Rated Current LD: 17.5 A (14.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.1 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-7.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 7.5kW ND, Safety SCEPA | Capacity ND: 7.5 kW (code 0170) | Motor LD: 11.0 kW | Rated Current ND: 17.0 A | Rated Current LD: 23.0 A (19.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.0 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-7.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 7.5kW ND, Safety SCEPB | Capacity ND: 7.5 kW (code 0170) | Motor LD: 11.0 kW | Rated Current ND: 17.0 A | Rated Current LD: 23.0 A (19.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.0 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-11KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 11.0kW ND, Safety SCEPA | Capacity ND: 11.0 kW (code 0230) | Motor LD: 15.0 kW | Rated Current ND: 23.0 A | Rated Current LD: 35.0 A (29.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 17.5 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-11KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 11.0kW ND, Safety SCEPB | Capacity ND: 11.0 kW (code 0230) | Motor LD: 15.0 kW | Rated Current ND: 23.0 A | Rated Current LD: 35.0 A (29.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 17.5 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-15KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 15.0kW ND, Safety SCEPA | Capacity ND: 15.0 kW (code 0300) | Motor LD: 18.5 kW | Rated Current ND: 30.0 A | Rated Current LD: 41.0 A (34.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 22.9 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-15KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 15.0kW ND, Safety SCEPB | Capacity ND: 15.0 kW (code 0300) | Motor LD: 18.5 kW | Rated Current ND: 30.0 A | Rated Current LD: 41.0 A (34.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 22.9 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-18.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 18.5kW ND, Safety SCEPA | Capacity ND: 18.5 kW (code 0380) | Motor LD: 22.0 kW | Rated Current ND: 38.0 A | Rated Current LD: 45.0 A (38.3 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 29.0 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-18.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 18.5kW ND, Safety SCEPB | Capacity ND: 18.5 kW (code 0380) | Motor LD: 22.0 kW | Rated Current ND: 38.0 A | Rated Current LD: 45.0 A (38.3 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 29.0 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-22KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 22.0kW ND, Safety SCEPA | Capacity ND: 22.0 kW (code 0440) | Motor LD: 30.0 kW | Rated Current ND: 44.0 A | Rated Current LD: 60.0 A (51.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 33.5 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-22KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 22.0kW ND, Safety SCEPB | Capacity ND: 22.0 kW (code 0440) | Motor LD: 30.0 kW | Rated Current ND: 44.0 A | Rated Current LD: 60.0 A (51.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 33.5 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396605870370,"sku":"MEL-FRE800-E840-SCE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-2_c781d665-224f-432c-903b-f576cb3b3653.png?v=1790662257","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-fr-e840-compact-inverter-3-phase-400v-0-4-22kw-safety-communication-sil3-ple","provider":"ProSource MRO","version":"1.0","type":"link"}