{"product_id":"mitsubishi-electric-freqrol-e700-3-phase-400v-vfd-standard-fm-terminal-0-4-15kw","title":"Mitsubishi Electric FREQROL-E700 3-Phase 400V VFD (Standard FM terminal, 0.4–15kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL-E700 3-phase 400V compact VFD, 0.4–15kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eStandard FM terminal\u003c\/li\u003e\n\u003cli\u003eAdvanced magnetic flux vector control with 200%\/0.5Hz starting torque (≤3.7K)\u003c\/li\u003e\n\u003cli\u003eUL\/cUL\/CE compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Current\u003c\/th\u003e\n\u003ctd\u003e150% 60s, 200% 3s (inverse-time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e3-Phase 380-480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e3-phase 380-480V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd\u003e325-528V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Tolerance\u003c\/th\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Method\u003c\/th\u003e\n\u003ctd\u003eV\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Frequency\u003c\/th\u003e\n\u003ctd\u003e400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePWM Carrier Frequency\u003c\/th\u003e\n\u003ctd\u003e0.7–14.5 kHz (Soft-PWM selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrake Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (0.4K and above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Structure\u003c\/th\u003e\n\u003ctd\u003eIP20 (enclosed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eRS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Function\u003c\/th\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-0.4K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-0.4K Standard FM terminal, 0.4kW | Applied Motor: 0.4 kW | Rated Capacity: 1.2 kVA | Rated Current: 1.6 A (1.4 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 100% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 1.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-0.75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-0.75K Standard FM terminal, 0.75kW | Applied Motor: 0.75 kW | Rated Capacity: 2.0 kVA | Rated Current: 2.6 A (2.2 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 100% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 2.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-1.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-1.5K Standard FM terminal, 1.5kW | Applied Motor: 1.5 kW | Rated Capacity: 3.0 kVA | Rated Current: 4.0 A (3.8 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 50% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 4.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.9 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-2.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-2.2K Standard FM terminal, 2.2kW | Applied Motor: 2.2 kW | Rated Capacity: 4.6 kVA | Rated Current: 6.0 A (5.4 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 5.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.9 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-3.7K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-3.7K Standard FM terminal, 3.7kW | Applied Motor: 3.7 kW | Rated Capacity: 7.2 kVA | Rated Current: 9.5 A (8.7 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 9.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.9 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-5.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-5.5K Standard FM terminal, 5.5kW | Applied Motor: 5.5 kW | Rated Capacity: 9.1 kVA | Rated Current: 12 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 12 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 3.2 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-7.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-7.5K Standard FM terminal, 7.5kW | Applied Motor: 7.5 kW | Rated Capacity: 13.0 kVA | Rated Current: 17 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 17 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 3.2 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-11K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-11K Standard FM terminal, 11kW | Applied Motor: 11 kW | Rated Capacity: 17.5 kVA | Rated Current: 23 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 20 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 6.0 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-15K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-15K Standard FM terminal, 15kW | Applied Motor: 15 kW | Rated Capacity: 23.0 kVA | Rated Current: 30 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 28 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 6.0 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396606263586,"sku":"MEL-FRE700-E740-STD","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-3_cd84eba5-5a30-433e-a10c-af49c555bf12.png?v=1790662266","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-freqrol-e700-3-phase-400v-vfd-standard-fm-terminal-0-4-15kw","provider":"ProSource MRO","version":"1.0","type":"link"}