{"product_id":"mitsubishi-electric-freqrol-fr-a840-gf-three-phase-400v-high-performance-inverter-with-built-in-cc-link-ie-field-network-0-4-280kw-nd","title":"Mitsubishi Electric FREQROL FR-A840-GF Three-Phase 400V High-Performance Inverter with Built-in CC-Link IE Field Network (0.4-280kW ND)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A840-GF high-performance inverter (VFD), Three-Phase 400V, ND 0.4-280kW, with built-in cc-link ie field network.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eReal\/PM sensorless vector, SLD\/LD\/ND\/HD selectable rating, FM\/CA output; same ratings as standard FR-A840\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd\u003eBuilt-in CC-Link IE Field Network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-0.4K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 0.4kW (00023), built-in cc-link ie field network | Applied Motor (ND): 0.4 kW | Max Applied Motor (SLD): 0.75 kW | Rated Output Current (ND): 1.5 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00023 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-0.75K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 0.75kW (00038), built-in cc-link ie field network | Applied Motor (ND): 0.75 kW | Max Applied Motor (SLD): 1.5 kW | Rated Output Current (ND): 2.5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00038 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-1.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 1.5kW (00052), built-in cc-link ie field network | Applied Motor (ND): 1.5 kW | Max Applied Motor (SLD): 2.2 kW | Rated Output Current (ND): 4 A | Rated Capacity (ND): 3 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00052 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-2.2K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 2.2kW (00083), built-in cc-link ie field network | Applied Motor (ND): 2.2 kW | Max Applied Motor (SLD): 3.7 kW | Rated Output Current (ND): 6 A | Rated Capacity (ND): 4.6 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00083 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-3.7K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 3.7kW (00126), built-in cc-link ie field network | Applied Motor (ND): 3.7 kW | Max Applied Motor (SLD): 5.5 kW | Rated Output Current (ND): 9 A | Rated Capacity (ND): 6.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00126 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-5.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 5.5kW (00170), built-in cc-link ie field network | Applied Motor (ND): 5.5 kW | Max Applied Motor (SLD): 7.5 kW | Rated Output Current (ND): 12 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00170 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-7.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 7.5kW (00250), built-in cc-link ie field network | Applied Motor (ND): 7.5 kW | Max Applied Motor (SLD): 11 kW | Rated Output Current (ND): 17 A | Rated Capacity (ND): 13 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00250 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-11K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 11kW (00310), built-in cc-link ie field network | Applied Motor (ND): 11 kW | Max Applied Motor (SLD): 15 kW | Rated Output Current (ND): 23 A | Rated Capacity (ND): 18 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00310 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-15K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 15kW (00380), built-in cc-link ie field network | Applied Motor (ND): 15 kW | Max Applied Motor (SLD): 18.5 kW | Rated Output Current (ND): 31 A | Rated Capacity (ND): 24 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00380 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-18.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 18.5kW (00470), built-in cc-link ie field network | Applied Motor (ND): 18.5 kW | Max Applied Motor (SLD): 22 kW | Rated Output Current (ND): 38 A | Rated Capacity (ND): 29 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00470 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-22K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 22kW (00620), built-in cc-link ie field network | Applied Motor (ND): 22 kW | Max Applied Motor (SLD): 30 kW | Rated Output Current (ND): 44 A | Rated Capacity (ND): 34 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00620 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-30K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 30kW (00770), built-in cc-link ie field network | Applied Motor (ND): 30 kW | Max Applied Motor (SLD): 37 kW | Rated Output Current (ND): 57 A | Rated Capacity (ND): 43 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00770 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-37K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 37kW (00930), built-in cc-link ie field network | Applied Motor (ND): 37 kW | Max Applied Motor (SLD): 45 kW | Rated Output Current (ND): 71 A | Rated Capacity (ND): 54 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00930 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-45K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 45kW (01160), built-in cc-link ie field network | Applied Motor (ND): 45 kW | Max Applied Motor (SLD): 55 kW | Rated Output Current (ND): 86 A | Rated Capacity (ND): 66 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01160 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-55K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 55kW (01800), built-in cc-link ie field network | Applied Motor (ND): 55 kW | Max Applied Motor (SLD): 75\/90 kW | Rated Output Current (ND): 110 A | Rated Capacity (ND): 84 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01800 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-75K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 75kW (02160), built-in cc-link ie field network | Applied Motor (ND): 75 kW | Max Applied Motor (SLD): 110 kW | Rated Output Current (ND): 144 A | Rated Capacity (ND): 110 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02160 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-90K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 90kW (02600), built-in cc-link ie field network | Applied Motor (ND): 90 kW | Max Applied Motor (SLD): 132 kW | Rated Output Current (ND): 180 A | Rated Capacity (ND): 137 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02600 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-110K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 110kW (03250), built-in cc-link ie field network | Applied Motor (ND): 110 kW | Max Applied Motor (SLD): 160 kW | Rated Output Current (ND): 216 A | Rated Capacity (ND): 165 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03250 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-132K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 132kW (03610), built-in cc-link ie field network | Applied Motor (ND): 132 kW | Max Applied Motor (SLD): 185 kW | Rated Output Current (ND): 260 A | Rated Capacity (ND): 198 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03610 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 78 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-160K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 160kW (04320), built-in cc-link ie field network | Applied Motor (ND): 160 kW | Max Applied Motor (SLD): 220 kW | Rated Output Current (ND): 325 A | Rated Capacity (ND): 248 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04320 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 117 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-185K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 185kW (04810), built-in cc-link ie field network | Applied Motor (ND): 185 kW | Max Applied Motor (SLD): 250 kW | Rated Output Current (ND): 361 A | Rated Capacity (ND): 275 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04810 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 117 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-220K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 220kW (05470), built-in cc-link ie field network | Applied Motor (ND): 220 kW | Max Applied Motor (SLD): 280 kW | Rated Output Current (ND): 432 A | Rated Capacity (ND): 329 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 05470 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-250K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 250kW (06100), built-in cc-link ie field network | Applied Motor (ND): 250 kW | Max Applied Motor (SLD): 315 kW | Rated Output Current (ND): 481 A | Rated Capacity (ND): 367 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 06100 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-280K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 280kW (06830), built-in cc-link ie field network | Applied Motor (ND): 280 kW | Max Applied Motor (SLD): 355 kW | Rated Output Current (ND): 547 A | Rated Capacity (ND): 417 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 06830 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604526882,"sku":"MEL-FRA800-A840-GF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_ee792cdd-310c-4c07-bb25-683ba3fce473.png?v=1790662229","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-freqrol-fr-a840-gf-three-phase-400v-high-performance-inverter-with-built-in-cc-link-ie-field-network-0-4-280kw-nd","provider":"ProSource MRO","version":"1.0","type":"link"}