{"product_id":"mitsubishi-electric-ms-t-n-series-ms-2xn180kp-enclosed-reversing-magnetic-starter-180a-ac-3-n180-frame-th-n220rhkp-3-element-thermal","title":"Mitsubishi Electric MS-T\/N Series MS-2xN180KP Enclosed Reversing Magnetic Starter (180A AC-3, N180 Frame, TH-N220RHKP 3-Element Thermal)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series N180-frame reversing enclosed-type magnetic starter MS-2xN180KP with TH-N220RHKP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eAC-operated, rated 45kW \/ 180A (AC-3) at 200-220V and 90kW \/ 180A at 380-440V, Ith 260A\u003c\/li\u003e\n\u003cli\u003eHeater designations 82A to 150A (4 steps)\u003c\/li\u003e\n\u003cli\u003eCompliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/li\u003e\n\u003cli\u003eMechanical interlock fitted as standard for forward\/reverse switching\u003c\/li\u003e\n\u003cli\u003eAuxiliary contact option units cannot be added to enclosed types\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eN180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eReversing Magnetic Starter (Enclosed Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eAC operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Relay\u003c\/th\u003e\n\u003ctd\u003eTH-N220RHKP (3-element 2E, manual reset)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eOverload + Open-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Capacity\u003c\/th\u003e\n\u003ctd\u003e45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Current\u003c\/th\u003e\n\u003ctd\u003e180A@200-220V \/ 180A@380-440V \/ 180A@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-1 Current\u003c\/th\u003e\n\u003ctd\u003e260A@200-220V \/ 260A@380-440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Current Ith\u003c\/th\u003e\n\u003ctd\u003e260A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e3a3b x2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterlock\u003c\/th\u003e\n\u003ctd\u003eMechanical, built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 82A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 82A heater, AC48V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 82A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 82A heater, AC100V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 82A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 82A heater, AC200V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 82A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 82A heater, AC300V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 82A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 82A heater, AC400V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 82A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 82A heater, AC500V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 105A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 105A heater, AC48V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 105A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 105A heater, AC100V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 105A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 105A heater, AC200V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 105A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 105A heater, AC300V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 105A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 105A heater, AC400V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 105A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 105A heater, AC500V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 125A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 125A heater, AC48V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 125A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 125A heater, AC100V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 125A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 125A heater, AC200V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 125A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 125A heater, AC300V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 125A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 125A heater, AC400V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 125A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 125A heater, AC500V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 150A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 150A heater, AC48V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 150A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 150A heater, AC100V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 150A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 150A heater, AC200V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 150A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 150A heater, AC300V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 150A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 150A heater, AC400V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMS-2xN180KP 150A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-2xN180KP reversing starter with 2E thermal, N180 frame, 150A heater, AC500V coil | Frame: N180 | Type: Reversing Magnetic Starter (Enclosed Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-N220RHKP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 45kW@200-220V \/ 90kW@380-440V \/ 110kW@500-550V | AC-3 Current: 180A@200-220V \/ 180A@380-440V \/ 180A@500-550V | AC-1 Current: 260A@200-220V \/ 260A@380-440V | Thermal Current Ith: 260A | Aux Contact: 3a3b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396642898210,"sku":"MEL-MSE-KP-2XN180","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/MS-2XT21KP-1_848391fa-f3d8-45a8-b448-4d3159002e47.png?v=1790662925","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-ms-t-n-series-ms-2xn180kp-enclosed-reversing-magnetic-starter-180a-ac-3-n180-frame-th-n220rhkp-3-element-thermal","provider":"ProSource MRO","version":"1.0","type":"link"}