{"product_id":"mitsubishi-electric-ms-t-n-series-mso-n125-magnetic-starter-125a-ac-3-n125-frame-th-n120ta-thermal","title":"Mitsubishi Electric MS-T\/N Series MSO-N125 Magnetic Starter (125A AC-3, N125 Frame, TH-N120(TA) Thermal)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series N125-frame non-reversing open-type magnetic starter MSO-N125: AC-operated contactor combined with TH-N120(TA) 2-element thermal overload relay (manual reset standard).\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRated 30kW \/ 125A (AC-3) at 200-220V and 60kW \/ 120A at 380-440V, Ith 150A\u003c\/li\u003e\n\u003cli\u003eHeater designations 42A to 105A (5 steps) for overload and open-phase protection matching\u003c\/li\u003e\n\u003cli\u003eCompliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eN125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eNon-Reversing Magnetic Starter (Open Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eAC operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Capacity\u003c\/th\u003e\n\u003ctd\u003e30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Current\u003c\/th\u003e\n\u003ctd\u003e125A@200-220V \/ 120A@380-440V \/ 90A@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-1 Current\u003c\/th\u003e\n\u003ctd\u003e150A@200-220V \/ 150A@380-440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Current Ith\u003c\/th\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e2a2b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eJIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 42A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 42A heater, AC24V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 42A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 42A heater, AC48V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 42A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 42A heater, AC100V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 42A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 42A heater, AC200V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 42A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 42A heater, AC300V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 42A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 42A heater, AC400V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 42A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 42A heater, AC500V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 54A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 54A heater, AC24V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 54A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 54A heater, AC48V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 54A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 54A heater, AC100V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 54A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 54A heater, AC200V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 54A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 54A heater, AC300V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 54A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 54A heater, AC400V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 54A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 54A heater, AC500V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 67A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 67A heater, AC24V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 67A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 67A heater, AC48V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 67A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 67A heater, AC100V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 67A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 67A heater, AC200V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 67A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 67A heater, AC300V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 67A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 67A heater, AC400V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 67A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 67A heater, AC500V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 82A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 82A heater, AC24V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 82A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 82A heater, AC48V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 82A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 82A heater, AC100V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 82A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 82A heater, AC200V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 82A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 82A heater, AC300V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 82A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 82A heater, AC400V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 82A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 82A heater, AC500V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-N120 (2-element, manual reset) | Heater: 82A (adjustable 65-100A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 105A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 105A heater, AC24V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-N120TA (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 105A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 105A heater, AC48V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-N120TA (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 105A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 105A heater, AC100V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-N120TA (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 105A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 105A heater, AC200V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-N120TA (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 105A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 105A heater, AC300V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50\/60Hz) | Thermal Relay: TH-N120TA (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 105A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 105A heater, AC400V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-N120TA (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-N125 105A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-N125 non-reversing starter, N125 frame, 105A heater, AC500V coil | Frame: N125 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-N120TA (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 30kW@200-220V \/ 60kW@380-440V \/ 60kW@500-550V | AC-3 Current: 125A@200-220V \/ 120A@380-440V \/ 90A@500-550V | AC-1 Current: 150A@200-220V \/ 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396630905122,"sku":"MEL-MSTR-N125","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-starter-n150-1_1247c213-1539-4e9d-a8d1-d1840b546b41.png?v=1790662665","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-ms-t-n-series-mso-n125-magnetic-starter-125a-ac-3-n125-frame-th-n120ta-thermal","provider":"ProSource MRO","version":"1.0","type":"link"}