{"product_id":"mitsubishi-electric-ms-t-n-series-mso-t10kp-magnetic-starter-11a-ac-3-t10-frame-th-t18kp-3-element-thermal","title":"Mitsubishi Electric MS-T\/N Series MSO-T10KP Magnetic Starter (11A AC-3, T10 Frame, TH-T18KP 3-Element Thermal)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series T10-frame non-reversing open-type magnetic starter MSO-T10KP with TH-T18KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eAC-operated, rated 2.2kW \/ 11A (AC-3) at 200-220V and 2.7kW \/ 7A at 380-440V, Ith 20A\u003c\/li\u003e\n\u003cli\u003eHeater designations 0.12A to 9A (15 steps)\u003c\/li\u003e\n\u003cli\u003eCompliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eT10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eNon-Reversing Magnetic Starter (Open Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eAC operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Relay\u003c\/th\u003e\n\u003ctd\u003eTH-T18KP (3-element 2E, manual reset)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eOverload + Open-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Capacity\u003c\/th\u003e\n\u003ctd\u003e2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Current\u003c\/th\u003e\n\u003ctd\u003e11A@200-220V \/ 7A@380-440V \/ 6A@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-1 Current\u003c\/th\u003e\n\u003ctd\u003e20A@200-220V \/ 11A@380-440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Current Ith\u003c\/th\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e1a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eJIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.12A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.12A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.12A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.12A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.12A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.12A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.12A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.12A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.12A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.12A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.12A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.12A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.12A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.12A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.17A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.17A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.17A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.17A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.17A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.17A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.17A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.17A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.17A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.17A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.17A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.17A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.17A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.17A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.24A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.24A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.24A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.24A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.24A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.24A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.24A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.24A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.24A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.24A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.24A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.24A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.24A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.24A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.35A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.35A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.35A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.35A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.35A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.35A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.35A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.35A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.35A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.35A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.35A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.35A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.35A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.35A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.5A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.5A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.5A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.5A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.5A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.5A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.5A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.5A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.5A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.5A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.5A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.5A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.5A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.5A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.7A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.7A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.7A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.7A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.7A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.7A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.7A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.7A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.7A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.7A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.7A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.7A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.7A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.7A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.9A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.9A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.9A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.9A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.9A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.9A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.9A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.9A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.9A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.9A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.9A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.9A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 0.9A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 0.9A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.3A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.3A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.3A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.3A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.3A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.3A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.3A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.3A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.3A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.3A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.3A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.3A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.3A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.3A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.7A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.7A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.7A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.7A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.7A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.7A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.7A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.7A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.7A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.7A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.7A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.7A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 1.7A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 1.7A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.1A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.1A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.1A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.1A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.1A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.1A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.1A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.1A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.1A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.1A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.1A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.1A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.1A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.1A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.5A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.5A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.5A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.5A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.5A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.5A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.5A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.5A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.5A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.5A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.5A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.5A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 2.5A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 2.5A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 3.6A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 3.6A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 3.6A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 3.6A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 3.6A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 3.6A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 3.6A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 3.6A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 3.6A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 3.6A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 3.6A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 3.6A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 3.6A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 3.6A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 5A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 5A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 5A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 5A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 5A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 5A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 5A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 5A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 5A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 5A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 5A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 5A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 5A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 5A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 6.6A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 6.6A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 6.6A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 6.6A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 6.6A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 6.6A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 6.6A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 6.6A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 6.6A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 6.6A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 6.6A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 6.6A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 6.6A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 6.6A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 9A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 9A heater, AC24V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 9A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 9A heater, AC48V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 9A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 9A heater, AC100V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 9A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 9A heater, AC200V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 9A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 9A heater, AC300V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 9A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 9A heater, AC400V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T10KP 9A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T10KP non-reversing starter with 2E thermal, T10 frame, 9A heater, AC500V coil | Frame: T10 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T18KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.2kW@200-220V \/ 2.7kW@380-440V \/ 2.7kW@500-550V | AC-3 Current: 11A@200-220V \/ 7A@380-440V \/ 6A@500-550V | AC-1 Current: 20A@200-220V \/ 11A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396638277922,"sku":"MEL-MSTR-KP-T10","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/MSO-KP-1.png?v=1790662797","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-ms-t-n-series-mso-t10kp-magnetic-starter-11a-ac-3-t10-frame-th-t18kp-3-element-thermal","provider":"ProSource MRO","version":"1.0","type":"link"}