{"product_id":"mitsubishi-electric-ms-t-n-series-mso-t35-magnetic-starter-34a-ac-3-t35-frame-th-t25-t50-thermal","title":"Mitsubishi Electric MS-T\/N Series MSO-T35 Magnetic Starter (34A AC-3, T35 Frame, TH-T25\/T50 Thermal)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series T35-frame non-reversing open-type magnetic starter MSO-T35: AC-operated contactor combined with TH-T25\/T50 2-element thermal overload relay (manual reset standard).\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRated 7.5kW \/ 34A (AC-3) at 200-220V and 15kW \/ 32A at 380-440V, Ith 60A\u003c\/li\u003e\n\u003cli\u003eHeater designations 0.24A to 29A (17 steps) for overload and open-phase protection matching\u003c\/li\u003e\n\u003cli\u003eCompliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eT35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eNon-Reversing Magnetic Starter (Open Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eAC operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Capacity\u003c\/th\u003e\n\u003ctd\u003e7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Current\u003c\/th\u003e\n\u003ctd\u003e34A@200-220V \/ 32A@380-440V \/ 26A@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-1 Current\u003c\/th\u003e\n\u003ctd\u003e60A@200-220V \/ 60A@380-440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Current Ith\u003c\/th\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e2a2b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eJIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.24A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.24A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.24A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.24A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.24A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.24A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.24A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.35A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.35A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.35A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.35A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.35A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.35A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.35A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.5A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.5A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.5A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.5A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.5A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.5A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.5A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.7A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.7A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.7A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.7A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.7A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.7A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.7A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.9A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.9A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.9A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.9A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.9A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.9A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 0.9A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.3A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.3A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.3A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.3A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.3A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.3A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.3A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.7A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.7A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.7A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.7A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.7A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.7A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 1.7A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.1A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.1A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.1A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.1A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.1A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.1A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.1A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.5A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.5A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.5A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.5A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.5A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.5A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 2.5A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 3.6A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 3.6A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 3.6A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 3.6A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 3.6A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 3.6A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 3.6A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 5A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 5A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 5A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 5A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 5A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 5A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 5A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 5A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 5A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 5A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 5A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 5A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 5A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 5A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 6.6A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 6.6A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 6.6A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 6.6A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 6.6A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 6.6A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 6.6A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 9A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 9A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 9A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 9A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 9A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 9A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 9A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 9A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 9A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 9A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 9A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 9A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 9A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 9A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 11A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 11A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 11A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 11A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 11A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 11A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 11A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 11A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 11A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 11A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 11A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 11A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 11A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 11A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 15A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 15A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 15A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 15A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 15A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 15A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 15A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 15A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 15A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 15A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 15A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 15A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 15A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 15A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 22A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 22A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 22A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 22A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 22A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 22A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 22A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 22A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 22A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 22A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 22A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 22A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 22A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 22A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T25 (2-element, manual reset) | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 29A AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 29A heater, AC24V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | Thermal Relay: TH-T50 (2-element, manual reset) | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 29A AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 29A heater, AC48V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | Thermal Relay: TH-T50 (2-element, manual reset) | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 29A AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 29A heater, AC100V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | Thermal Relay: TH-T50 (2-element, manual reset) | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 29A AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 29A heater, AC200V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | Thermal Relay: TH-T50 (2-element, manual reset) | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 29A AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 29A heater, AC300V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | Thermal Relay: TH-T50 (2-element, manual reset) | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 29A AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 29A heater, AC400V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | Thermal Relay: TH-T50 (2-element, manual reset) | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSO-T35 29A AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSO-T35 non-reversing starter, T35 frame, 29A heater, AC500V coil | Frame: T35 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | Thermal Relay: TH-T50 (2-element, manual reset) | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 7.5kW@200-220V \/ 15kW@380-440V \/ 15kW@500-550V | AC-3 Current: 34A@200-220V \/ 32A@380-440V \/ 26A@500-550V | AC-1 Current: 60A@200-220V \/ 60A@380-440V | Thermal Current Ith: 60A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396629365026,"sku":"MEL-MSTR-T35","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-starter-n150-1_62bc84a4-63ad-4fdc-b35c-5db192687af6.png?v=1790662659","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-ms-t-n-series-mso-t35-magnetic-starter-34a-ac-3-t35-frame-th-t25-t50-thermal","provider":"ProSource MRO","version":"1.0","type":"link"}