{"product_id":"mitsubishi-electric-ms-t-n-series-msod-2xt12-reversing-magnetic-starter-13a-ac-3-t12-frame-th-t18-thermal","title":"Mitsubishi Electric MS-T\/N Series MSOD-2xT12 Reversing Magnetic Starter (13A AC-3, T12 Frame, TH-T18 Thermal)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series T12-frame reversing open-type magnetic starter MSOD-2xT12: DC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard).\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRated 2.7kW \/ 13A (AC-3) at 200-220V and 4kW \/ 9A at 380-440V, Ith 20A\u003c\/li\u003e\n\u003cli\u003eHeater designations 0.12A to 11A (16 steps) for overload and open-phase protection matching\u003c\/li\u003e\n\u003cli\u003eCompliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability\u003c\/li\u003e\n\u003cli\u003eMechanical interlock fitted as standard for forward\/reverse motor switching\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eT12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eReversing Magnetic Starter (Open Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eDC operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Relay\u003c\/th\u003e\n\u003ctd\u003eTH-T18 (2-element, manual reset)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Capacity\u003c\/th\u003e\n\u003ctd\u003e2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Current\u003c\/th\u003e\n\u003ctd\u003e13A@200-220V \/ 9A@380-440V \/ 9A@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-1 Current\u003c\/th\u003e\n\u003ctd\u003e20A@200-220V \/ 13A@380-440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Current Ith\u003c\/th\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e1a1b x2 + 2b (interlock unit b-contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterlock\u003c\/th\u003e\n\u003ctd\u003eMechanical, built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eJIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.12A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.12A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.12A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.12A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.12A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.12A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.12A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.12A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.12A (adjustable 0.1-0.16A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.17A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.17A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.17A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.17A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.17A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.17A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.17A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.17A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.17A (adjustable 0.14-0.22A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.24A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.24A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.24A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.24A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.24A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.24A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.24A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.24A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.24A (adjustable 0.2-0.32A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.35A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.35A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.35A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.35A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.35A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.35A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.35A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.35A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.35A (adjustable 0.28-0.42A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.5A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.5A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.5A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.5A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.5A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.5A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.5A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.5A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.5A (adjustable 0.4-0.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.7A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.7A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.7A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.7A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.7A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.7A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.7A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.7A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.7A (adjustable 0.55-0.85A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.9A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.9A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.9A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.9A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.9A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.9A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.9A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 0.9A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 0.9A (adjustable 0.7-1.1A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.3A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.3A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.3A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.3A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.3A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.3A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.3A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.3A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.3A (adjustable 1-1.6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.7A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.7A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.7A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.7A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.7A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.7A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.7A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 1.7A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 1.7A (adjustable 1.4-2A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.1A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.1A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.1A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.1A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.1A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.1A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.1A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.1A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.1A (adjustable 1.7-2.5A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.5A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.5A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.5A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.5A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.5A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.5A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.5A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 2.5A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 2.5A (adjustable 2-3A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 3.6A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 3.6A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 3.6A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 3.6A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 3.6A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 3.6A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 3.6A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 3.6A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 3.6A (adjustable 2.8-4.4A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 5A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 5A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 5A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 5A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 5A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 5A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 5A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 5A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 5A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 5A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 5A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 5A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 5A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 5A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 5A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 5A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 5A (adjustable 4-6A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 6.6A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 6.6A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 6.6A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 6.6A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 6.6A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 6.6A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 6.6A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 6.6A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 6.6A (adjustable 5.2-8A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 9A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 9A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 9A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 9A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 9A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 9A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 9A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 9A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 9A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 9A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 9A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 9A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 9A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 9A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 9A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 9A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 9A (adjustable 7-11A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 11A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 11A heater, DC12V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 11A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 11A heater, DC24V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 11A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 11A heater, DC48V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 11A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 11A heater, DC100V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 11A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 11A heater, DC110V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 11A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 11A heater, DC125V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 11A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 11A heater, DC200V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT12 11A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT12 reversing starter, T12 frame, 11A heater, DC220V coil | Frame: T12 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T18 (2-element, manual reset) | Heater: 11A (adjustable 9-13A) | AC-3 Capacity: 2.7kW@200-220V \/ 4kW@380-440V \/ 5.5kW@500-550V | AC-3 Current: 13A@200-220V \/ 9A@380-440V \/ 9A@500-550V | AC-1 Current: 20A@200-220V \/ 13A@380-440V | Thermal Current Ith: 20A | Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396633690402,"sku":"MEL-MSTR-D-2XT12","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/MSTN_photo_SD-N220-1_a715d490-5163-4f17-b553-2a8102e8649a.png?v=1790662712","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-ms-t-n-series-msod-2xt12-reversing-magnetic-starter-13a-ac-3-t12-frame-th-t18-thermal","provider":"ProSource MRO","version":"1.0","type":"link"}