{"product_id":"mitsubishi-electric-ms-t-n-series-msod-2xt80kp-reversing-magnetic-starter-80a-ac-3-t80-frame-th-t100kp-3-element-thermal","title":"Mitsubishi Electric MS-T\/N Series MSOD-2xT80KP Reversing Magnetic Starter (80A AC-3, T80 Frame, TH-T100KP 3-Element Thermal)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series T80-frame reversing open-type magnetic starter MSOD-2xT80KP with TH-T100KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDC-operated, rated 19kW \/ 80A (AC-3) at 200-220V and 37kW \/ 80A at 380-440V, Ith 120A\u003c\/li\u003e\n\u003cli\u003eHeater designations 67A to 67A (1 steps)\u003c\/li\u003e\n\u003cli\u003eCompliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/li\u003e\n\u003cli\u003eMechanical interlock fitted as standard for forward\/reverse switching\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eT80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eReversing Magnetic Starter (Open Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eDC operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Relay\u003c\/th\u003e\n\u003ctd\u003eTH-T100KP (3-element 2E, manual reset)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eOverload + Open-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeater\u003c\/th\u003e\n\u003ctd\u003e67A (adjustable 54-80A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Capacity\u003c\/th\u003e\n\u003ctd\u003e19kW@200-220V \/ 37kW@380-440V \/ 45kW@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Current\u003c\/th\u003e\n\u003ctd\u003e80A@200-220V \/ 80A@380-440V \/ 75A@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-1 Current\u003c\/th\u003e\n\u003ctd\u003e120A@200-220V \/ 120A@380-440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Current Ith\u003c\/th\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e2a2b x2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT80KP 67A DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT80KP reversing starter with 2E thermal, T80 frame, 67A heater, DC12V coil | Frame: T80 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | Thermal Relay: TH-T100KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 19kW@200-220V \/ 37kW@380-440V \/ 45kW@500-550V | AC-3 Current: 80A@200-220V \/ 80A@380-440V \/ 75A@500-550V | AC-1 Current: 120A@200-220V \/ 120A@380-440V | Thermal Current Ith: 120A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT80KP 67A DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT80KP reversing starter with 2E thermal, T80 frame, 67A heater, DC24V coil | Frame: T80 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | Thermal Relay: TH-T100KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 19kW@200-220V \/ 37kW@380-440V \/ 45kW@500-550V | AC-3 Current: 80A@200-220V \/ 80A@380-440V \/ 75A@500-550V | AC-1 Current: 120A@200-220V \/ 120A@380-440V | Thermal Current Ith: 120A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT80KP 67A DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT80KP reversing starter with 2E thermal, T80 frame, 67A heater, DC48V coil | Frame: T80 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | Thermal Relay: TH-T100KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 19kW@200-220V \/ 37kW@380-440V \/ 45kW@500-550V | AC-3 Current: 80A@200-220V \/ 80A@380-440V \/ 75A@500-550V | AC-1 Current: 120A@200-220V \/ 120A@380-440V | Thermal Current Ith: 120A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT80KP 67A DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT80KP reversing starter with 2E thermal, T80 frame, 67A heater, DC100V coil | Frame: T80 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | Thermal Relay: TH-T100KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 19kW@200-220V \/ 37kW@380-440V \/ 45kW@500-550V | AC-3 Current: 80A@200-220V \/ 80A@380-440V \/ 75A@500-550V | AC-1 Current: 120A@200-220V \/ 120A@380-440V | Thermal Current Ith: 120A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT80KP 67A DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT80KP reversing starter with 2E thermal, T80 frame, 67A heater, DC110V coil | Frame: T80 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | Thermal Relay: TH-T100KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 19kW@200-220V \/ 37kW@380-440V \/ 45kW@500-550V | AC-3 Current: 80A@200-220V \/ 80A@380-440V \/ 75A@500-550V | AC-1 Current: 120A@200-220V \/ 120A@380-440V | Thermal Current Ith: 120A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT80KP 67A DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT80KP reversing starter with 2E thermal, T80 frame, 67A heater, DC125V coil | Frame: T80 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | Thermal Relay: TH-T100KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 19kW@200-220V \/ 37kW@380-440V \/ 45kW@500-550V | AC-3 Current: 80A@200-220V \/ 80A@380-440V \/ 75A@500-550V | AC-1 Current: 120A@200-220V \/ 120A@380-440V | Thermal Current Ith: 120A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT80KP 67A DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT80KP reversing starter with 2E thermal, T80 frame, 67A heater, DC200V coil | Frame: T80 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | Thermal Relay: TH-T100KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 19kW@200-220V \/ 37kW@380-440V \/ 45kW@500-550V | AC-3 Current: 80A@200-220V \/ 80A@380-440V \/ 75A@500-550V | AC-1 Current: 120A@200-220V \/ 120A@380-440V | Thermal Current Ith: 120A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMSOD-2xT80KP 67A DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMSOD-2xT80KP reversing starter with 2E thermal, T80 frame, 67A heater, DC220V coil | Frame: T80 | Type: Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | Thermal Relay: TH-T100KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 67A (adjustable 54-80A) | AC-3 Capacity: 19kW@200-220V \/ 37kW@380-440V \/ 45kW@500-550V | AC-3 Current: 80A@200-220V \/ 80A@380-440V \/ 75A@500-550V | AC-1 Current: 120A@200-220V \/ 120A@380-440V | Thermal Current Ith: 120A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396641554722,"sku":"MEL-MSTR-D-KP-2XT80","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/MSO-2XT21KP-1_f217d145-ad99-426d-badb-e2b3b3b9e170.png?v=1790662889","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-ms-t-n-series-msod-2xt80kp-reversing-magnetic-starter-80a-ac-3-t80-frame-th-t100kp-3-element-thermal","provider":"ProSource MRO","version":"1.0","type":"link"}