{"product_id":"mitsubishi-electric-ms-t-n-series-s-2xt21-sd-2xt21-reversing-magnetic-contactor-20a-ac-3-t21-frame","title":"Mitsubishi Electric MS-T\/N Series S-2xT21 \/ SD-2xT21 Reversing Magnetic Contactor (20A AC-3, T21 Frame)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series T21-frame reversing magnetic contactor S-2xT21 \/ SD-2xT21, rated 4kW \/ 20A (AC-3) at 200-220V and 7.5kW \/ 20A at 380-440V, conventional thermal current Ith 32A.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eCompliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability\u003c\/li\u003e\n\u003cli\u003eAC operating coils AC24V-AC500V (S type) and DC coils DC12V-DC220V (SD type)\u003c\/li\u003e\n\u003cli\u003eMechanical interlock fitted as standard for forward\/reverse motor switching\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eT21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eReversing Magnetic Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Capacity\u003c\/th\u003e\n\u003ctd\u003e4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Current\u003c\/th\u003e\n\u003ctd\u003e20A@200-220V \/ 20A@380-440V \/ 17A@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-1 Current\u003c\/th\u003e\n\u003ctd\u003e32A@200-220V \/ 32A@380-440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Current Ith\u003c\/th\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e2a2b x2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterlock\u003c\/th\u003e\n\u003ctd\u003eMechanical, built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eJIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2xT21 AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2xT21 reversing contactor, T21 frame, AC24V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50\/60Hz) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2xT21 AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2xT21 reversing contactor, T21 frame, AC48V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50\/60Hz) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2xT21 AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2xT21 reversing contactor, T21 frame, AC100V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2xT21 AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2xT21 reversing contactor, T21 frame, AC200V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2xT21 AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2xT21 reversing contactor, T21 frame, AC300V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC300V (260-300V 50\/60Hz) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2xT21 AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2xT21 reversing contactor, T21 frame, AC400V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2xT21 AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2xT21 reversing contactor, T21 frame, AC500V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-2xT21 DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-2xT21 reversing contactor, T21 frame, DC12V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-2xT21 DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-2xT21 reversing contactor, T21 frame, DC24V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-2xT21 DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-2xT21 reversing contactor, T21 frame, DC48V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-2xT21 DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-2xT21 reversing contactor, T21 frame, DC100V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-2xT21 DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-2xT21 reversing contactor, T21 frame, DC110V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-2xT21 DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-2xT21 reversing contactor, T21 frame, DC125V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-2xT21 DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-2xT21 reversing contactor, T21 frame, DC200V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-2xT21 DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-2xT21 reversing contactor, T21 frame, DC220V coil | Frame: T21 | Type: Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | AC-3 Capacity: 4kW@200-220V \/ 7.5kW@380-440V \/ 7.5kW@500-550V | AC-3 Current: 20A@200-220V \/ 20A@380-440V \/ 17A@500-550V | AC-1 Current: 32A@200-220V \/ 32A@380-440V | Thermal Current Ith: 32A | Aux Contact: 2a2b x2 | Interlock: Mechanical, built-in | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396628414754,"sku":"MEL-CONT-2XT21","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-contactor-2xt21-rev-1_2a2a7100-d1fe-4957-ba60-85ee2ba95058.png?v=1790662635","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-ms-t-n-series-s-2xt21-sd-2xt21-reversing-magnetic-contactor-20a-ac-3-t21-frame","provider":"ProSource MRO","version":"1.0","type":"link"}