{"product_id":"mitsubishi-electric-ms-t-n-series-s-n800-sd-n800-magnetic-contactor-800a-ac-3-n800-frame","title":"Mitsubishi Electric MS-T\/N Series S-N800 \/ SD-N800 Magnetic Contactor (800A AC-3, N800 Frame)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series N800-frame non-reversing magnetic contactor S-N800 \/ SD-N800, rated 200kW \/ 800A (AC-3) at 200-220V and 400kW \/ 800A at 380-440V, conventional thermal current Ith 800A.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eCompliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability\u003c\/li\u003e\n\u003cli\u003eAC operating coils AC100V-AC500V (S type) and DC coils DC24V-DC200V (SD type)\u003c\/li\u003e\n\u003cli\u003eStandard auxiliary contacts: 2a2b\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eN800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eNon-Reversing Magnetic Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Capacity\u003c\/th\u003e\n\u003ctd\u003e200kW@200-220V \/ 400kW@380-440V \/ 400kW@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 Current\u003c\/th\u003e\n\u003ctd\u003e800A@200-220V \/ 800A@380-440V \/ 720A@500-550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-1 Current\u003c\/th\u003e\n\u003ctd\u003e800A@200-220V \/ 800A@380-440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal Current Ith\u003c\/th\u003e\n\u003ctd\u003e800A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e2a2b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eJIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N800 AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N800 non-reversing contactor, N800 frame, AC100V coil | Frame: N800 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50\/60Hz) | AC-3 Capacity: 200kW@200-220V \/ 400kW@380-440V \/ 400kW@500-550V | AC-3 Current: 800A@200-220V \/ 800A@380-440V \/ 720A@500-550V | AC-1 Current: 800A@200-220V \/ 800A@380-440V | Thermal Current Ith: 800A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N800 AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N800 non-reversing contactor, N800 frame, AC200V coil | Frame: N800 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50\/60Hz) | AC-3 Capacity: 200kW@200-220V \/ 400kW@380-440V \/ 400kW@500-550V | AC-3 Current: 800A@200-220V \/ 800A@380-440V \/ 720A@500-550V | AC-1 Current: 800A@200-220V \/ 800A@380-440V | Thermal Current Ith: 800A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N800 AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N800 non-reversing contactor, N800 frame, AC300V coil | Frame: N800 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50\/60Hz) | AC-3 Capacity: 200kW@200-220V \/ 400kW@380-440V \/ 400kW@500-550V | AC-3 Current: 800A@200-220V \/ 800A@380-440V \/ 720A@500-550V | AC-1 Current: 800A@200-220V \/ 800A@380-440V | Thermal Current Ith: 800A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N800 AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N800 non-reversing contactor, N800 frame, AC400V coil | Frame: N800 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50\/60Hz) | AC-3 Capacity: 200kW@200-220V \/ 400kW@380-440V \/ 400kW@500-550V | AC-3 Current: 800A@200-220V \/ 800A@380-440V \/ 720A@500-550V | AC-1 Current: 800A@200-220V \/ 800A@380-440V | Thermal Current Ith: 800A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N800 AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N800 non-reversing contactor, N800 frame, AC500V coil | Frame: N800 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50\/60Hz) | AC-3 Capacity: 200kW@200-220V \/ 400kW@380-440V \/ 400kW@500-550V | AC-3 Current: 800A@200-220V \/ 800A@380-440V \/ 720A@500-550V | AC-1 Current: 800A@200-220V \/ 800A@380-440V | Thermal Current Ith: 800A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-N800 DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-N800 non-reversing contactor, N800 frame, DC24V coil | Frame: N800 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | AC-3 Capacity: 200kW@200-220V \/ 400kW@380-440V \/ 400kW@500-550V | AC-3 Current: 800A@200-220V \/ 800A@380-440V \/ 720A@500-550V | AC-1 Current: 800A@200-220V \/ 800A@380-440V | Thermal Current Ith: 800A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-N800 DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-N800 non-reversing contactor, N800 frame, DC48V coil | Frame: N800 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | AC-3 Capacity: 200kW@200-220V \/ 400kW@380-440V \/ 400kW@500-550V | AC-3 Current: 800A@200-220V \/ 800A@380-440V \/ 720A@500-550V | AC-1 Current: 800A@200-220V \/ 800A@380-440V | Thermal Current Ith: 800A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-N800 DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-N800 non-reversing contactor, N800 frame, DC100V coil | Frame: N800 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | AC-3 Capacity: 200kW@200-220V \/ 400kW@380-440V \/ 400kW@500-550V | AC-3 Current: 800A@200-220V \/ 800A@380-440V \/ 720A@500-550V | AC-1 Current: 800A@200-220V \/ 800A@380-440V | Thermal Current Ith: 800A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-N800 DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-N800 non-reversing contactor, N800 frame, DC125V coil | Frame: N800 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | AC-3 Capacity: 200kW@200-220V \/ 400kW@380-440V \/ 400kW@500-550V | AC-3 Current: 800A@200-220V \/ 800A@380-440V \/ 720A@500-550V | AC-1 Current: 800A@200-220V \/ 800A@380-440V | Thermal Current Ith: 800A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-N800 DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSD-N800 non-reversing contactor, N800 frame, DC200V coil | Frame: N800 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | AC-3 Capacity: 200kW@200-220V \/ 400kW@380-440V \/ 400kW@500-550V | AC-3 Current: 800A@200-220V \/ 800A@380-440V \/ 720A@500-550V | AC-1 Current: 800A@200-220V \/ 800A@380-440V | Thermal Current Ith: 800A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396628119842,"sku":"MEL-CONT-N800","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-contactor-st50-1_ffde9cae-18de-48ae-9d4b-c6d759c25dd6.png?v=1790662630","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-ms-t-n-series-s-n800-sd-n800-magnetic-contactor-800a-ac-3-n800-frame","provider":"ProSource MRO","version":"1.0","type":"link"}