{"product_id":"mitsubishi-electric-s-n150fn-class-2-heat-resistant-magnetic-contactor-ac-operated-140a-carrying-140a-ac-3-at-220v","title":"Mitsubishi Electric - S-N150FN Class 2 Heat Resistant Magnetic Contactor (AC Operated, 140A Carrying, 140A AC-3 at 220V)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series S-N150FN class 2 heat-resistant magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRetains conduction and insulation function at high temperature during a fire so that power to fire fighting equipment continues, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve\u003c\/li\u003e\n\u003cli\u003eHeat-resistant carrying current 140A, heat-resistant rated current 140A at 220V, 140A at 440V, 140A at 550V under AC-3 class and 140A at 220V, 140A at 440V under AC-1 class, 3a main contacts\u003c\/li\u003e\n\u003cli\u003eAC operated coil, durability and outline dimensions the same as the standard product\u003c\/li\u003e\n\u003cli\u003eReversing type S-2XN150FN is available\u003c\/li\u003e\n\u003cli\u003eType approval number 2MC-99138\u003c\/li\u003e\n\u003cli\u003eCertified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eClass 2 heat-resistant magnetic contactor for emergency power switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eN150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eAC operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Contact\u003c\/th\u003e\n\u003ctd\u003e3a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Carrying Current\u003c\/th\u003e\n\u003ctd\u003e140A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Rated Current AC-3 Class\u003c\/th\u003e\n\u003ctd\u003e140A at 220V, 140A at 440V, 140A at 550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Rated Current AC-1 Class\u003c\/th\u003e\n\u003ctd\u003e140A at 220V, 140A at 440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC48V\u003c\/th\u003e\n\u003ctd\u003e100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC110V\u003c\/th\u003e\n\u003ctd\u003e80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC220V\u003c\/th\u003e\n\u003ctd\u003e60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDurability\u003c\/th\u003e\n\u003ctd\u003eSame as the standard product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType Approval Number\u003c\/th\u003e\n\u003ctd\u003e2MC-99138\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N150FN AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N150FN class 2 heat-resistant contactor, AC24V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC24V | Coil Rating: 24V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XN150FN AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XN150FN class 2 heat-resistant contactor, AC24V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC24V | Coil Rating: 24V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N150FN AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N150FN class 2 heat-resistant contactor, AC48V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC48V | Coil Rating: 48-50V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XN150FN AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XN150FN class 2 heat-resistant contactor, AC48V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC48V | Coil Rating: 48-50V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N150FN AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N150FN class 2 heat-resistant contactor, AC100V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC100V | Coil Rating: 100-127V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XN150FN AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XN150FN class 2 heat-resistant contactor, AC100V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC100V | Coil Rating: 100-127V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N150FN AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N150FN class 2 heat-resistant contactor, AC200V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC200V | Coil Rating: 200-240V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XN150FN AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XN150FN class 2 heat-resistant contactor, AC200V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC200V | Coil Rating: 200-240V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N150FN AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N150FN class 2 heat-resistant contactor, AC300V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC300V | Coil Rating: 260-350V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XN150FN AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XN150FN class 2 heat-resistant contactor, AC300V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC300V | Coil Rating: 260-350V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N150FN AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N150FN class 2 heat-resistant contactor, AC400V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC400V | Coil Rating: 380-440V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XN150FN AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XN150FN class 2 heat-resistant contactor, AC400V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC400V | Coil Rating: 380-440V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-N150FN AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-N150FN class 2 heat-resistant contactor, AC500V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC500V | Coil Rating: 460-550V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XN150FN AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XN150FN class 2 heat-resistant contactor, AC500V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: N150 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC500V | Coil Rating: 460-550V 50\/60Hz | Heat Resistant Carrying Current: 140A | Heat Resistant Rated Current AC-3 Class: 140A at 220V, 140A at 440V, 140A at 550V | Heat Resistant Rated Current AC-1 Class: 140A at 220V, 140A at 440V | DC Rated Current at DC48V: 100A 2-pole series, 130A 3-pole series (DC2 and DC4 class), 120A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC110V: 80A 2-pole series, 120A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | DC Rated Current at DC220V: 60A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 140A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-99138 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396647878946,"sku":"MEL-FN-N150","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-fkfn-std-1_81a179ed-acff-4774-bc80-7cf1da3bfea2.png?v=1790663036","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-s-n150fn-class-2-heat-resistant-magnetic-contactor-ac-operated-140a-carrying-140a-ac-3-at-220v","provider":"ProSource MRO","version":"1.0","type":"link"}