{"product_id":"mitsubishi-electric-s-t100fn-class-2-heat-resistant-magnetic-contactor-ac-operated-105a-carrying-100a-ac-3-at-220v","title":"Mitsubishi Electric - S-T100FN Class 2 Heat Resistant Magnetic Contactor (AC Operated, 105A Carrying, 100A AC-3 at 220V)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series S-T100FN class 2 heat-resistant magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRetains conduction and insulation function at high temperature during a fire so that power to fire fighting equipment continues, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve\u003c\/li\u003e\n\u003cli\u003eHeat-resistant carrying current 105A, heat-resistant rated current 100A at 220V, 93A at 440V, 75A at 550V under AC-3 class and 105A at 220V, 105A at 440V under AC-1 class, 3a main contacts\u003c\/li\u003e\n\u003cli\u003eAC operated coil, durability and outline dimensions the same as the standard product\u003c\/li\u003e\n\u003cli\u003eReversing type S-2XT100FN is available\u003c\/li\u003e\n\u003cli\u003eType approval number 2MC-16175\u003c\/li\u003e\n\u003cli\u003eCertified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eClass 2 heat-resistant magnetic contactor for emergency power switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eT100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eAC operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Contact\u003c\/th\u003e\n\u003ctd\u003e3a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Carrying Current\u003c\/th\u003e\n\u003ctd\u003e105A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Rated Current AC-3 Class\u003c\/th\u003e\n\u003ctd\u003e100A at 220V, 93A at 440V, 75A at 550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Rated Current AC-1 Class\u003c\/th\u003e\n\u003ctd\u003e105A at 220V, 105A at 440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC48V\u003c\/th\u003e\n\u003ctd\u003e60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC110V\u003c\/th\u003e\n\u003ctd\u003e40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC220V\u003c\/th\u003e\n\u003ctd\u003e30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDurability\u003c\/th\u003e\n\u003ctd\u003eSame as the standard product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType Approval Number\u003c\/th\u003e\n\u003ctd\u003e2MC-16175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T100FN AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-T100FN class 2 heat-resistant contactor, AC24V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC24V | Coil Rating: 24V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XT100FN AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XT100FN class 2 heat-resistant contactor, AC24V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC24V | Coil Rating: 24V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T100FN AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-T100FN class 2 heat-resistant contactor, AC48V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC48V | Coil Rating: 48-50V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XT100FN AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XT100FN class 2 heat-resistant contactor, AC48V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC48V | Coil Rating: 48-50V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T100FN AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-T100FN class 2 heat-resistant contactor, AC100V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC100V | Coil Rating: 100-127V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XT100FN AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XT100FN class 2 heat-resistant contactor, AC100V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC100V | Coil Rating: 100-127V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T100FN AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-T100FN class 2 heat-resistant contactor, AC200V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC200V | Coil Rating: 200-240V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XT100FN AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XT100FN class 2 heat-resistant contactor, AC200V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC200V | Coil Rating: 200-240V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T100FN AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-T100FN class 2 heat-resistant contactor, AC300V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC300V | Coil Rating: 260-350V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XT100FN AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XT100FN class 2 heat-resistant contactor, AC300V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC300V | Coil Rating: 260-350V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T100FN AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-T100FN class 2 heat-resistant contactor, AC400V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC400V | Coil Rating: 380-440V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XT100FN AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XT100FN class 2 heat-resistant contactor, AC400V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC400V | Coil Rating: 380-440V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T100FN AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-T100FN class 2 heat-resistant contactor, AC500V coil, non-reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b | Coil Designation: AC500V | Coil Rating: 460-550V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-2XT100FN AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eS-2XT100FN class 2 heat-resistant contactor, AC500V coil, reversing | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards | Frame: T100 | Configuration: Reversing | Operation: AC operated | Main Contact: 3a | Aux Contact: 2a2b x2 | Coil Designation: AC500V | Coil Rating: 460-550V 50\/60Hz | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16175 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396647846178,"sku":"MEL-FN-T100","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-fkfn-std-1_e951f05d-1b23-4dc1-823f-ce6db30027ed.png?v=1790663034","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-s-t100fn-class-2-heat-resistant-magnetic-contactor-ac-operated-105a-carrying-100a-ac-3-at-220v","provider":"ProSource MRO","version":"1.0","type":"link"}