{"product_id":"mitsubishi-electric-s-t12sq-sd-t12sq-magnetic-contactor-spring-clamp","title":"Mitsubishi Electric S-T12SQ \/ SD-T12SQ Spring Clamp Contactor (13A)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric S-T12SQ (AC) \/ SD-T12SQ (DC) magnetic contactor with screwless spring clamp terminals for faster, maintenance-free wiring.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eWAGO PUSH-IN CAGE CLAMP spring terminals - insert solid wires or ferrules, no terminal screws to loosen\u003c\/li\u003e\n\u003cli\u003eTwo wire openings per pole for crossover wiring; terminals inclined about 15 deg to reduce wire protrusion\u003c\/li\u003e\n\u003cli\u003eAC-3 rating 2.7 kW \/ 13 A at 200-220V, 4 kW \/ 9 A at 380-440V; Ith 20 A\u003c\/li\u003e\n\u003cli\u003eAuxiliary contacts 1a1b, 2a or 2b (S type); 1a1b or 2a (SD type)\u003c\/li\u003e\n\u003cli\u003eAlmost the same size as the screw type (+1.7 mm height); IEC rail or screw mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eMS-T series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eT12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003ctd\u003eSpring clamp (PUSH-IN CAGE CLAMP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 rating 200-220V\u003c\/th\u003e\n\u003ctd\u003e2.7 kW \/ 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC-3 rating 380-440V\u003c\/th\u003e\n\u003ctd\u003e4 kW \/ 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConventional thermal current Ith\u003c\/th\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eMitsubishi Electric MS-T\/N Series catalogue L(NA)02031ENG, p. 125-126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T12SQ AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: S-T12SQ | Operation: AC | Coil: AC24V | Coil rated voltage: 24V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T12SQ AC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: S-T12SQ | Operation: AC | Coil: AC48V | Coil rated voltage: 48-50V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T12SQ AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: S-T12SQ | Operation: AC | Coil: AC100V | Coil rated voltage: 100-127V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T12SQ AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: S-T12SQ | Operation: AC | Coil: AC200V | Coil rated voltage: 200-240V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T12SQ AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: S-T12SQ | Operation: AC | Coil: AC300V | Coil rated voltage: 260-300V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T12SQ AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: S-T12SQ | Operation: AC | Coil: AC400V | Coil rated voltage: 380-440V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-T12SQ AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: S-T12SQ | Operation: AC | Coil: AC500V | Coil rated voltage: 460-550V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-T12SQ DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD-T12SQ | Operation: DC | Coil: DC12V | Coil rated voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-T12SQ DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD-T12SQ | Operation: DC | Coil: DC24V | Coil rated voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-T12SQ DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD-T12SQ | Operation: DC | Coil: DC48V | Coil rated voltage: DC48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-T12SQ DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD-T12SQ | Operation: DC | Coil: DC100V | Coil rated voltage: DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-T12SQ DC110V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD-T12SQ | Operation: DC | Coil: DC110V | Coil rated voltage: DC110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-T12SQ DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD-T12SQ | Operation: DC | Coil: DC125V | Coil rated voltage: DC120-125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-T12SQ DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD-T12SQ | Operation: DC | Coil: DC200V | Coil rated voltage: DC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD-T12SQ DC220V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD-T12SQ | Operation: DC | Coil: DC220V | Coil rated voltage: DC220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67534143783202,"sku":"S-T12SQ AC24V","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-contactor-st50-1_a9ffaadc-a544-408b-885a-acff46aa8f23.png?v=1790662611","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-s-t12sq-sd-t12sq-magnetic-contactor-spring-clamp","provider":"ProSource MRO","version":"1.0","type":"link"}