{"product_id":"mitsubishi-electric-shld-v400-vacuum-magnetic-contactor-mechanical-latch-dc-operated-450a-ith-400a-200kw-at-ac440v","title":"Mitsubishi Electric - SHLD-V400 Vacuum Magnetic Contactor (Mechanical Latch, DC operated, 450A Ith, 400A 200kW at AC440V)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series SHLD-V400 large capacity vacuum magnetic contactor combining a vacuum switch with an AC operated DC excited electromagnet for high performance, long life and maintenance free operation.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eMechanical latch mechanism holds the contacts without continuous coil excitation\u003c\/li\u003e\n\u003cli\u003eNo arc clearance is required so the panel can be made smaller, there is no coil humming or current interruption noise, and there is no arc blowout which keeps the unit safe in harsh ambient conditions\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 1200 operations per hour\u003c\/li\u003e\n\u003cli\u003eElectrical 250,000 operations on three phase motor AC-3 class, 100,000 operations on three phase capacitor, mechanical 250,000 operations\u003c\/li\u003e\n\u003cli\u003eStandard auxiliary contacts 2a2b, with a 4a4b configuration available on request\u003c\/li\u003e\n\u003cli\u003eCompliant with JIS C8201-4-1, JEM 1038, IEC 60947-4-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eMechanical latch vacuum magnetic contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eV400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanism\u003c\/th\u003e\n\u003ctd\u003eMechanical latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eDC operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Insulation Voltage\u003c\/th\u003e\n\u003ctd\u003e1500V three phase 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current and Capacity AC-3 Class\u003c\/th\u003e\n\u003ctd\u003e400A 95kW at AC220V, 400A 200kW at AC440V, 400A 250kW at AC550V, 400A 500kW at AC1000V, 400A 750kW at AC1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThree Phase Capacitor Rating\u003c\/th\u003e\n\u003ctd\u003e300A 100kVA at AC220V, 300A 200kVA at AC440V, 300A 250kVA at AC550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOpen Thermal Current Ith\u003c\/th\u003e\n\u003ctd\u003e450A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching Frequency\u003c\/th\u003e\n\u003ctd\u003e1200 operations\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Voltage\u003c\/th\u003e\n\u003ctd\u003ePick up at 85 percent or less of rated voltage at 40 degrees C ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics\u003c\/th\u003e\n\u003ctd\u003eMain contact ON 40ms, main contact OFF 30ms, inrush coil input 480VA closing and 300VA tripping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eJIS C8201-4-1, JEM 1038, IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHLD-V400 MC-DC100V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSHLD-V400 vacuum latch contactor, MC DC100V and MT DC100V | Type: Mechanical latch vacuum magnetic contactor | Frame: V400 | Mechanism: Mechanical latch | Operation: DC operated | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC100V rated DC100-110V | Rated Insulation Voltage: 1500V three phase 50\/60Hz | Rated Current and Capacity AC-3 Class: 400A 95kW at AC220V, 400A 200kW at AC440V, 400A 250kW at AC550V, 400A 500kW at AC1000V, 400A 750kW at AC1500V | Three Phase Capacitor Rating: 300A 100kVA at AC220V, 300A 200kVA at AC440V, 300A 250kVA at AC550V | Open Thermal Current Ith: 450A | Switching Frequency: 1200 operations\/h | Durability: Electrical 250,000 operations on three phase motor AC-3 class, 100,000 operations on three phase capacitor, mechanical 250,000 operations | Operating Voltage: Pick up at 85 percent or less of rated voltage at 40 degrees C ambient | Characteristics: Main contact ON 40ms, main contact OFF 30ms, inrush coil input 480VA closing and 300VA tripping | Aux Contact: 2a2b standard, rated operational current AC-15 class 5A at AC220V and 3A at AC440V, DC-13 class 0.6A at DC110V and 0.2A at DC220V, conforming to JIS C4531 (1994) | Standards: JIS C8201-4-1, JEM 1038, IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHLD-V400 MC-DC100V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSHLD-V400 vacuum latch contactor, MC DC100V and MT DC200V | Type: Mechanical latch vacuum magnetic contactor | Frame: V400 | Mechanism: Mechanical latch | Operation: DC operated | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC200V rated DC200-220V | Rated Insulation Voltage: 1500V three phase 50\/60Hz | Rated Current and Capacity AC-3 Class: 400A 95kW at AC220V, 400A 200kW at AC440V, 400A 250kW at AC550V, 400A 500kW at AC1000V, 400A 750kW at AC1500V | Three Phase Capacitor Rating: 300A 100kVA at AC220V, 300A 200kVA at AC440V, 300A 250kVA at AC550V | Open Thermal Current Ith: 450A | Switching Frequency: 1200 operations\/h | Durability: Electrical 250,000 operations on three phase motor AC-3 class, 100,000 operations on three phase capacitor, mechanical 250,000 operations | Operating Voltage: Pick up at 85 percent or less of rated voltage at 40 degrees C ambient | Characteristics: Main contact ON 40ms, main contact OFF 30ms, inrush coil input 480VA closing and 300VA tripping | Aux Contact: 2a2b standard, rated operational current AC-15 class 5A at AC220V and 3A at AC440V, DC-13 class 0.6A at DC110V and 0.2A at DC220V, conforming to JIS C4531 (1994) | Standards: JIS C8201-4-1, JEM 1038, IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHLD-V400 MC-DC200V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSHLD-V400 vacuum latch contactor, MC DC200V and MT DC100V | Type: Mechanical latch vacuum magnetic contactor | Frame: V400 | Mechanism: Mechanical latch | Operation: DC operated | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC100V rated DC100-110V | Rated Insulation Voltage: 1500V three phase 50\/60Hz | Rated Current and Capacity AC-3 Class: 400A 95kW at AC220V, 400A 200kW at AC440V, 400A 250kW at AC550V, 400A 500kW at AC1000V, 400A 750kW at AC1500V | Three Phase Capacitor Rating: 300A 100kVA at AC220V, 300A 200kVA at AC440V, 300A 250kVA at AC550V | Open Thermal Current Ith: 450A | Switching Frequency: 1200 operations\/h | Durability: Electrical 250,000 operations on three phase motor AC-3 class, 100,000 operations on three phase capacitor, mechanical 250,000 operations | Operating Voltage: Pick up at 85 percent or less of rated voltage at 40 degrees C ambient | Characteristics: Main contact ON 40ms, main contact OFF 30ms, inrush coil input 480VA closing and 300VA tripping | Aux Contact: 2a2b standard, rated operational current AC-15 class 5A at AC220V and 3A at AC440V, DC-13 class 0.6A at DC110V and 0.2A at DC220V, conforming to JIS C4531 (1994) | Standards: JIS C8201-4-1, JEM 1038, IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHLD-V400 MC-DC200V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSHLD-V400 vacuum latch contactor, MC DC200V and MT DC200V | Type: Mechanical latch vacuum magnetic contactor | Frame: V400 | Mechanism: Mechanical latch | Operation: DC operated | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC200V rated DC200-220V | Rated Insulation Voltage: 1500V three phase 50\/60Hz | Rated Current and Capacity AC-3 Class: 400A 95kW at AC220V, 400A 200kW at AC440V, 400A 250kW at AC550V, 400A 500kW at AC1000V, 400A 750kW at AC1500V | Three Phase Capacitor Rating: 300A 100kVA at AC220V, 300A 200kVA at AC440V, 300A 250kVA at AC550V | Open Thermal Current Ith: 450A | Switching Frequency: 1200 operations\/h | Durability: Electrical 250,000 operations on three phase motor AC-3 class, 100,000 operations on three phase capacitor, mechanical 250,000 operations | Operating Voltage: Pick up at 85 percent or less of rated voltage at 40 degrees C ambient | Characteristics: Main contact ON 40ms, main contact OFF 30ms, inrush coil input 480VA closing and 300VA tripping | Aux Contact: 2a2b standard, rated operational current AC-15 class 5A at AC220V and 3A at AC440V, DC-13 class 0.6A at DC110V and 0.2A at DC220V, conforming to JIS C4531 (1994) | Standards: JIS C8201-4-1, JEM 1038, IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396650041634,"sku":"MEL-SHV-LD-V400","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-shv-1_2d7542e8-0dd5-475f-8f88-5171f00dd397.png?v=1790663091","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-shld-v400-vacuum-magnetic-contactor-mechanical-latch-dc-operated-450a-ith-400a-200kw-at-ac440v","provider":"ProSource MRO","version":"1.0","type":"link"}