{"product_id":"mitsubishi-electric-sl-n50fk-class-1-heat-resistant-mechanical-latch-magnetic-contactor-ac-operated-closing-coil-56a-carrying-50a-ac-3-at-220v","title":"Mitsubishi Electric - SL-N50FK Class 1 Heat Resistant Mechanical Latch Magnetic Contactor (AC Operated Closing Coil, 56A Carrying, 50A AC-3 at 220V)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series SL-N50FK class 1 heat-resistant mechanical latch magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRetains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one third fire temperature curve\u003c\/li\u003e\n\u003cli\u003eHeat-resistant carrying current 56A, heat-resistant rated current 50A at AC220V, 48A at AC440V, 38A at AC550V under AC-3 class, 3a main contacts with 2a2b auxiliary contacts\u003c\/li\u003e\n\u003cli\u003eSeparate closing coil MC and tripping coil MT are specified independently; the closing coil is AC operated in AC24V, AC100V, AC200V and AC230V designations and the tripping coil may be any of the AC24V, AC100V, AC200V, AC230V, DC100V and DC200V designations\u003c\/li\u003e\n\u003cli\u003eMechanical and electrical durability 250,000 operations\u003c\/li\u003e\n\u003cli\u003eReversing type SL-2XN50FK is available, and the contactor can be switched from its own auxiliary contacts\u003c\/li\u003e\n\u003cli\u003eOutline dimensions are the same as the standard product\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eClass 1 heat-resistant magnetic contactor for emergency power switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eN50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Contact\u003c\/th\u003e\n\u003ctd\u003e3a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanism\u003c\/th\u003e\n\u003ctd\u003eMechanical latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eAC operated closing coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Carrying Current\u003c\/th\u003e\n\u003ctd\u003e56A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Rated Current AC-3 Class\u003c\/th\u003e\n\u003ctd\u003e50A at AC220V, 48A at AC440V, 38A at AC550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Rated Current AC-1 Class\u003c\/th\u003e\n\u003ctd\u003e56A at AC220V, 56A at AC440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC48V\u003c\/th\u003e\n\u003ctd\u003e25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC110V\u003c\/th\u003e\n\u003ctd\u003e15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC220V\u003c\/th\u003e\n\u003ctd\u003e3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Inrush Input\u003c\/th\u003e\n\u003ctd\u003eInrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC24V MT-AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC24V MT-AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC24V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC24V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC24V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC24V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC24V MT-AC230V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC24V MT-AC230V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC24V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC24V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC24V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC24V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC100V MT-AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC100V MT-AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC100V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC100V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC100V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC100V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC100V MT-AC230V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC100V MT-AC230V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC100V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC100V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC100V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC100V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC200V MT-AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC200V MT-AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC200V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC200V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC200V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC200V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC200V MT-AC230V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC200V MT-AC230V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC200V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC200V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC200V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC200V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC230V MT-AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC230V MT-AC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC230V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC230V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC230V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC230V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC230V MT-AC230V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC230V MT-AC230V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC230V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC230V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-N50FK MC-AC230V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XN50FK MC-AC230V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396647485730,"sku":"MEL-FK-SL-N50","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-fkfn-latch-1.png?v=1790663022","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-sl-n50fk-class-1-heat-resistant-mechanical-latch-magnetic-contactor-ac-operated-closing-coil-56a-carrying-50a-ac-3-at-220v","provider":"ProSource MRO","version":"1.0","type":"link"}