{"product_id":"mitsubishi-electric-sl-t50fn-class-2-heat-resistant-mechanical-latch-magnetic-contactor-ac-operated-closing-coil-56a-carrying-50a-ac-3-at-220v","title":"Mitsubishi Electric - SL-T50FN Class 2 Heat Resistant Mechanical Latch Magnetic Contactor (AC Operated Closing Coil, 56A Carrying, 50A AC-3 at 220V)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series SL-T50FN class 2 heat-resistant mechanical latch magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRetains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve\u003c\/li\u003e\n\u003cli\u003eHeat-resistant carrying current 56A, heat-resistant rated current 50A at 220V, 48A at 440V, 38A at 550V under AC-3 class, 3a main contacts with 2a2b auxiliary contacts\u003c\/li\u003e\n\u003cli\u003eClosing coil MC and tripping coil MT are specified independently; the closing coil is AC operated and the tripping coil may be any AC or DC designation available on the frame\u003c\/li\u003e\n\u003cli\u003eReversing type SL-2XT50FN is available\u003c\/li\u003e\n\u003cli\u003eDurability and outline dimensions are the same as the standard product\u003c\/li\u003e\n\u003cli\u003eType approval number 2MC-16176\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eClass 2 heat-resistant mechanical latch magnetic contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eT50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanism\u003c\/th\u003e\n\u003ctd\u003eMechanical latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eAC operated closing coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Contact\u003c\/th\u003e\n\u003ctd\u003e3a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Carrying Current\u003c\/th\u003e\n\u003ctd\u003e56A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Rated Current AC-3 Class\u003c\/th\u003e\n\u003ctd\u003e50A at 220V, 48A at 440V, 38A at 550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Rated Current AC-1 Class\u003c\/th\u003e\n\u003ctd\u003e56A at 220V, 56A at 440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC48V\u003c\/th\u003e\n\u003ctd\u003e25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC110V\u003c\/th\u003e\n\u003ctd\u003e15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC220V\u003c\/th\u003e\n\u003ctd\u003e3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Voltage\u003c\/th\u003e\n\u003ctd\u003eAC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC100V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC100V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC100V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC100V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC100V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC100V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC100V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC100V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC100V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC100V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC100V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC100V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC100V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC100V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC100V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC100V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC100V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC100V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC100V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC100V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC100V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC100V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC200V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC200V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC200V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC200V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC200V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC200V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC200V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC200V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC200V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC200V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC200V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC200V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC200V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC200V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC200V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC200V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC200V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC200V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC200V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC200V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC200V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC200V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC300V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC300V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC300V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC300V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC300V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC300V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC300V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC300V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC300V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC300V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC300V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC300V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC300V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC300V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC300V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC300V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC300V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC300V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC300V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC300V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC300V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC300V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC400V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC400V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC400V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC400V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC400V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC400V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC400V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC400V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC400V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC400V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC400V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC400V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC400V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC400V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC400V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC400V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC400V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC400V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC400V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC400V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC400V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC400V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC500V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC500V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC500V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC500V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC500V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC500V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC500V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC500V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC500V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC500V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC500V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC500V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC500V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC500V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC500V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC500V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC500V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC500V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC500V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC500V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-T50FN MC-AC500V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL-2XT50FN MC-AC500V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396648632610,"sku":"MEL-FN-SL-T50","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-fkfn-latch-1_582cdb04-1b7c-4b44-a457-4c3bf09770dd.png?v=1790663044","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-sl-t50fn-class-2-heat-resistant-mechanical-latch-magnetic-contactor-ac-operated-closing-coil-56a-carrying-50a-ac-3-at-220v","provider":"ProSource MRO","version":"1.0","type":"link"}