{"product_id":"mitsubishi-electric-sld-t100fn-class-2-heat-resistant-mechanical-latch-magnetic-contactor-dc-operated-closing-coil-105a-carrying-100a-ac-3-at-220v","title":"Mitsubishi Electric - SLD-T100FN Class 2 Heat Resistant Mechanical Latch Magnetic Contactor (DC Operated Closing Coil, 105A Carrying, 100A AC-3 at 220V)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series SLD-T100FN class 2 heat-resistant mechanical latch magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRetains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve\u003c\/li\u003e\n\u003cli\u003eHeat-resistant carrying current 105A, heat-resistant rated current 100A at 220V, 93A at 440V, 75A at 550V under AC-3 class, 3a main contacts with 2a2b auxiliary contacts\u003c\/li\u003e\n\u003cli\u003eClosing coil MC and tripping coil MT are specified independently; the closing coil is DC operated and the tripping coil may be any AC or DC designation available on the frame\u003c\/li\u003e\n\u003cli\u003eReversing type SLD-2XT100FN is available\u003c\/li\u003e\n\u003cli\u003eDurability and outline dimensions are the same as the standard product\u003c\/li\u003e\n\u003cli\u003eType approval number 2MC-16178\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eClass 2 heat-resistant mechanical latch magnetic contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eT100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanism\u003c\/th\u003e\n\u003ctd\u003eMechanical latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eDC operated closing coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Contact\u003c\/th\u003e\n\u003ctd\u003e3a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Carrying Current\u003c\/th\u003e\n\u003ctd\u003e105A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Rated Current AC-3 Class\u003c\/th\u003e\n\u003ctd\u003e100A at 220V, 93A at 440V, 75A at 550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Rated Current AC-1 Class\u003c\/th\u003e\n\u003ctd\u003e105A at 220V, 105A at 440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC48V\u003c\/th\u003e\n\u003ctd\u003e60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC110V\u003c\/th\u003e\n\u003ctd\u003e40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Rated Current at DC220V\u003c\/th\u003e\n\u003ctd\u003e30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDurability\u003c\/th\u003e\n\u003ctd\u003eSame as the standard product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC12V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC12V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC12V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC12V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC12V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC12V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC12V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC12V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC12V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC12V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC12V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC12V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC12V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC12V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC12V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC12V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC12V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC12V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC12V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC12V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC12V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC12V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC12V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC12V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC12V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC12V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC12V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC12V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC12V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC12V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC12V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC12V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC12V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC24V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC24V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC24V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC24V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC24V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC24V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC24V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC24V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC24V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC24V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC24V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC24V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC24V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC24V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC24V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC24V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC24V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC24V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC24V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC24V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC24V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC24V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC24V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC24V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC24V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC24V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC24V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC24V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC24V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC24V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC24V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC24V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC24V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC48V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC48V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC48V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC48V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC48V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC48V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC48V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC48V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC48V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC48V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC48V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC48V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC48V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC48V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC48V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC48V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC48V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC48V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC48V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC48V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC48V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC48V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC48V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC48V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC48V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC48V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC48V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC48V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC48V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC48V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC48V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC48V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC48V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC100V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC100V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC100V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC100V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC100V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC100V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC100V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC100V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC100V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC100V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC100V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC100V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC100V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC100V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC100V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC100V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC100V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC100V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC100V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC100V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC100V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC100V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC100V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC100V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC100V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC100V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC100V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC100V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC100V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC100V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC100V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC100V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC100V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC125V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC125V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC125V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC125V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC125V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC125V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC125V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC125V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC125V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC125V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC125V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC125V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC125V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC125V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC125V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC125V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC125V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC125V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC125V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC125V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC125V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC125V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC125V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC125V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC125V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC125V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC125V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC125V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC125V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC125V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC125V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC125V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC125V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC200V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC200V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC200V MT-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC200V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC200V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC200V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC200V MT-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC200V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC200V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC200V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC200V MT-AC300V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC200V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC200V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC200V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC200V MT-AC400V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC200V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC200V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC200V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC200V MT-AC500V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC200V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC200V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC200V MT-DC12V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC200V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC200V MT-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC200V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC200V MT-DC48V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC200V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC200V MT-DC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC200V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC200V MT-DC125V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-T100FN MC-DC200V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-T100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSLD-2XT100FN MC-DC200V MT-DC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSLD-2XT100FN class 2 heat-resistant latch contactor, MC DC200V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: DC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50\/60Hz or DC100-110V for AC100V and 200-240V at 50\/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396648829218,"sku":"MEL-FN-SLD-T100","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-fkfn-latch-1_c4a597ee-9fbb-4abb-a2b1-281dccbbb482.png?v=1790663051","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-sld-t100fn-class-2-heat-resistant-mechanical-latch-magnetic-contactor-dc-operated-closing-coil-105a-carrying-100a-ac-3-at-220v","provider":"ProSource MRO","version":"1.0","type":"link"}