{"product_id":"mitsubishi-electric-sre-aau-voltage-detection-relay-standard-detection-dc-0-1v-to-ac-250v-ac115-120v-or-ac230-240v","title":"Mitsubishi Electric - SRE-AAU Voltage Detection Relay (Standard Detection, DC 0.1V to AC 250V, AC115-120V or AC230-240V)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series SRE-AAU voltage detection relay for high precision detection of DC or AC overvoltage and undervoltage, with setting ranges spanning 0.1V up to 250V across eleven detection designations.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eSeven DC detection designations from DC 0.1 to 0.5V up to DC 50 to 250V and four AC detection designations from AC 3 to 15V up to AC 50 to 250V are available; the DC detection versions can also be used on a single phase full wave supply\u003c\/li\u003e\n\u003cli\u003eOperating voltage AC115-120V or AC230-240V 50\/60Hz common\u003c\/li\u003e\n\u003cli\u003eOutput contact 1c rated AC110V 1.5A and AC220V 1A under AC-15 class with 500,000 operation electrical durability, and DC110V 0.2A under DC-13 class with 250,000 operations\u003c\/li\u003e\n\u003cli\u003eVoltage variation characteristic plus or minus 1.5 percent over 85 to 110 percent of rated operating voltage, power consumption 2VA\u003c\/li\u003e\n\u003cli\u003eSurge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/li\u003e\n\u003cli\u003eA CCC certified version is available by adding CN to the model name\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eStandard voltage detection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Voltage\u003c\/th\u003e\n\u003ctd\u003eAC115-120V or AC230-240V 50\/60Hz common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Variation Characteristic\u003c\/th\u003e\n\u003ctd\u003e85 to 110 percent of rated operating voltage, plus or minus 1.5 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003e2VA at rated operating voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge Withstand\u003c\/th\u003e\n\u003ctd\u003eSurge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAU 0P5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAU voltage detection relay, DC 0.1 to 0.5V detection | Type: Standard voltage detection relay | Certification Variant: Standard | Detection Designation: 0P5D | Detection Setting Range: DC 0.1 to 0.5V | Maximum Continuous Input Voltage: plus or minus 100V | Input Impedance: 20 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAUCN 0P5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAUCN voltage detection relay, DC 0.1 to 0.5V detection | Type: Standard voltage detection relay | Certification Variant: CCC certified item | Detection Designation: 0P5D | Detection Setting Range: DC 0.1 to 0.5V | Maximum Continuous Input Voltage: plus or minus 100V | Input Impedance: 20 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAU 1P5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAU voltage detection relay, DC 0.3 to 1.5V detection | Type: Standard voltage detection relay | Certification Variant: Standard | Detection Designation: 1P5D | Detection Setting Range: DC 0.3 to 1.5V | Maximum Continuous Input Voltage: plus or minus 100V | Input Impedance: 50 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAUCN 1P5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAUCN voltage detection relay, DC 0.3 to 1.5V detection | Type: Standard voltage detection relay | Certification Variant: CCC certified item | Detection Designation: 1P5D | Detection Setting Range: DC 0.3 to 1.5V | Maximum Continuous Input Voltage: plus or minus 100V | Input Impedance: 50 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAU 005D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAU voltage detection relay, DC 1 to 5V detection | Type: Standard voltage detection relay | Certification Variant: Standard | Detection Designation: 005D | Detection Setting Range: DC 1 to 5V | Maximum Continuous Input Voltage: plus or minus 150V | Input Impedance: 100 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAUCN 005D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAUCN voltage detection relay, DC 1 to 5V detection | Type: Standard voltage detection relay | Certification Variant: CCC certified item | Detection Designation: 005D | Detection Setting Range: DC 1 to 5V | Maximum Continuous Input Voltage: plus or minus 150V | Input Impedance: 100 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAU 015D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAU voltage detection relay, DC 3 to 15V detection | Type: Standard voltage detection relay | Certification Variant: Standard | Detection Designation: 015D | Detection Setting Range: DC 3 to 15V | Maximum Continuous Input Voltage: plus or minus 150V | Input Impedance: 100 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAUCN 015D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAUCN voltage detection relay, DC 3 to 15V detection | Type: Standard voltage detection relay | Certification Variant: CCC certified item | Detection Designation: 015D | Detection Setting Range: DC 3 to 15V | Maximum Continuous Input Voltage: plus or minus 150V | Input Impedance: 100 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAU 050D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAU voltage detection relay, DC 10 to 50V detection | Type: Standard voltage detection relay | Certification Variant: Standard | Detection Designation: 050D | Detection Setting Range: DC 10 to 50V | Maximum Continuous Input Voltage: plus or minus 200V | Input Impedance: 500 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAUCN 050D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAUCN voltage detection relay, DC 10 to 50V detection | Type: Standard voltage detection relay | Certification Variant: CCC certified item | Detection Designation: 050D | Detection Setting Range: DC 10 to 50V | Maximum Continuous Input Voltage: plus or minus 200V | Input Impedance: 500 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAU 150D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAU voltage detection relay, DC 30 to 150V detection | Type: Standard voltage detection relay | Certification Variant: Standard | Detection Designation: 150D | Detection Setting Range: DC 30 to 150V | Maximum Continuous Input Voltage: plus or minus 300V | Input Impedance: 800 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAUCN 150D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAUCN voltage detection relay, DC 30 to 150V detection | Type: Standard voltage detection relay | Certification Variant: CCC certified item | Detection Designation: 150D | Detection Setting Range: DC 30 to 150V | Maximum Continuous Input Voltage: plus or minus 300V | Input Impedance: 800 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAU 250D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAU voltage detection relay, DC 50 to 250V detection | Type: Standard voltage detection relay | Certification Variant: Standard | Detection Designation: 250D | Detection Setting Range: DC 50 to 250V | Maximum Continuous Input Voltage: plus or minus 300V | Input Impedance: 800 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAUCN 250D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAUCN voltage detection relay, DC 50 to 250V detection | Type: Standard voltage detection relay | Certification Variant: CCC certified item | Detection Designation: 250D | Detection Setting Range: DC 50 to 250V | Maximum Continuous Input Voltage: plus or minus 300V | Input Impedance: 800 kilohm | Detection Type: DC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAU 015A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAU voltage detection relay, AC 3 to 15V detection | Type: Standard voltage detection relay | Certification Variant: Standard | Detection Designation: 015A | Detection Setting Range: AC 3 to 15V | Maximum Continuous Input Voltage: AC150V | Input Impedance: 100 kilohm | Detection Type: AC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAUCN 015A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAUCN voltage detection relay, AC 3 to 15V detection | Type: Standard voltage detection relay | Certification Variant: CCC certified item | Detection Designation: 015A | Detection Setting Range: AC 3 to 15V | Maximum Continuous Input Voltage: AC150V | Input Impedance: 100 kilohm | Detection Type: AC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAU 050A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAU voltage detection relay, AC 10 to 50V detection | Type: Standard voltage detection relay | Certification Variant: Standard | Detection Designation: 050A | Detection Setting Range: AC 10 to 50V | Maximum Continuous Input Voltage: AC200V | Input Impedance: 500 kilohm | Detection Type: AC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAUCN 050A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAUCN voltage detection relay, AC 10 to 50V detection | Type: Standard voltage detection relay | Certification Variant: CCC certified item | Detection Designation: 050A | Detection Setting Range: AC 10 to 50V | Maximum Continuous Input Voltage: AC200V | Input Impedance: 500 kilohm | Detection Type: AC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAU 150A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAU voltage detection relay, AC 30 to 150V detection | Type: Standard voltage detection relay | Certification Variant: Standard | Detection Designation: 150A | Detection Setting Range: AC 30 to 150V | Maximum Continuous Input Voltage: AC300V | Input Impedance: 800 kilohm | Detection Type: AC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAUCN 150A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAUCN voltage detection relay, AC 30 to 150V detection | Type: Standard voltage detection relay | Certification Variant: CCC certified item | Detection Designation: 150A | Detection Setting Range: AC 30 to 150V | Maximum Continuous Input Voltage: AC300V | Input Impedance: 800 kilohm | Detection Type: AC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAU 250A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAU voltage detection relay, AC 50 to 250V detection | Type: Standard voltage detection relay | Certification Variant: Standard | Detection Designation: 250A | Detection Setting Range: AC 50 to 250V | Maximum Continuous Input Voltage: AC300V | Input Impedance: 800 kilohm | Detection Type: AC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRE-AAUCN 250A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRE-AAUCN voltage detection relay, AC 50 to 250V detection | Type: Standard voltage detection relay | Certification Variant: CCC certified item | Detection Designation: 250A | Detection Setting Range: AC 50 to 250V | Maximum Continuous Input Voltage: AC300V | Input Impedance: 800 kilohm | Detection Type: AC detection | Operating Voltage: AC115-120V or AC230-240V 50\/60Hz common | Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A | Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent | Power Consumption: 2VA at rated operating voltage | Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396651286818,"sku":"MEL-SRE-AAU","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-sre-1_358aedba-ccff-4d74-a637-8f0a9924c105.png?v=1790663132","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-sre-aau-voltage-detection-relay-standard-detection-dc-0-1v-to-ac-250v-ac115-120v-or-ac230-240v","provider":"ProSource MRO","version":"1.0","type":"link"}