{"product_id":"mitsubishi-electric-srld-t5fn-class-2-heat-resistant-mechanical-latch-auxiliary-relay-10a-carrying-5a-4a1b-3a2b","title":"Mitsubishi Electric - SRLD-T5FN Class 2 Heat Resistant Mechanical Latch Auxiliary Relay (10A Carrying, 5a, 4a1b, 3a2b)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric MS-T\/N series SRLD-T5FN class 2 heat-resistant mechanical latch auxiliary relay for distribution boards and panelboards of dedicated emergency power receiving equipment.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRetains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve\u003c\/li\u003e\n\u003cli\u003eHeat-resistant carrying current 10A with heat-resistant rated current 6A at 110V and 3A at 220V under AC-15 class\u003c\/li\u003e\n\u003cli\u003eContact configurations 5a, 4a1b, 3a2b\u003c\/li\u003e\n\u003cli\u003eDC operated closing coil with tripping coil freely specified from the AC or DC designations\u003c\/li\u003e\n\u003cli\u003eDurability and outline dimensions are the same as the standard product\u003c\/li\u003e\n\u003cli\u003eType approval number 2RY-14042\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eClass 2 heat-resistant mechanical latch auxiliary relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eT5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanism\u003c\/th\u003e\n\u003ctd\u003eMechanical latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003eDC operated closing coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Resistant Carrying Current\u003c\/th\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDurability\u003c\/th\u003e\n\u003ctd\u003eSame as the standard product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType Approval Number\u003c\/th\u003e\n\u003ctd\u003e2RY-14042\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC300V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC300V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC300V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC300V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC300V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC300V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC400V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC400V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC400V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC400V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC400V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC400V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC500V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC500V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC500V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC500V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC500V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC500V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-AC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT AC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC125V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC125V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC125V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC125V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC125V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC125V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC12V MT-DC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC12V and MT DC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC12V rated DC12V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC300V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC300V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC300V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC300V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC300V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC300V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC400V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC400V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC400V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC400V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC400V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC400V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC500V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC500V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC500V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC500V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC500V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC500V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-AC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT AC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC125V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC125V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC125V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC125V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC125V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC125V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC24V MT-DC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC24V and MT DC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC24V rated DC24V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC300V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC300V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC300V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC300V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC300V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC300V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC400V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC400V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC400V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC400V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC400V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC400V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC500V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC500V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC500V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC500V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC500V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC500V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-AC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT AC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC125V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC125V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC125V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC125V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC125V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC125V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC48V MT-DC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC48V and MT DC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC48V rated DC48V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC300V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC300V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC300V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC300V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC300V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC300V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC400V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC400V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC400V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC400V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC400V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC400V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC500V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC500V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC500V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC500V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC500V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC500V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-AC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT AC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC125V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC125V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC125V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC125V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC125V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC125V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC100V MT-DC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC100V and MT DC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC100V rated DC100-110V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC300V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC300V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC300V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC300V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC300V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC300V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC400V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC400V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC400V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC400V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC400V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC400V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC500V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC500V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC500V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC500V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC500V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC500V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-AC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT AC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC125V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC125V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC125V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC125V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC125V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC125V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC125V MT-DC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC125V and MT DC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC125V rated DC120-125V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC100V rated 100-127V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC200V rated 200-240V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC300V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC300V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC300V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC300V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC300V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC300V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC300V rated 260-350V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC400V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC400V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC400V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC400V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC400V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC400V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC400V rated 380-440V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC500V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC500V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC500V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC500V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC500V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC500V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC500V rated 460-550V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC12V rated 12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC24V rated 24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-AC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT AC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: AC48V rated 48-50V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC12V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC12V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC12V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC12V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC12V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC12V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC12V rated DC12V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC24V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC24V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC24V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC24V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC24V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC24V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC24V rated DC24V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC48V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC48V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC48V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC48V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC48V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC48V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC48V rated DC48V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC100V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC100V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC100V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC100V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC100V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC100V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC125V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC125V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC125V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC125V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC125V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC125V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC125V rated DC120-125V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC200V 5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC200V, 5a | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 5a | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC200V 4A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC200V, 4a1b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 4a1b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRLD-T5FN MC-DC200V MT-DC200V 3A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSRLD-T5FN class 2 heat-resistant latch auxiliary relay, MC DC200V and MT DC200V, 3a2b | Type: Class 2 heat-resistant mechanical latch auxiliary relay | Frame: T5 | Mechanism: Mechanical latch | Operation: DC operated closing coil | Contact Configuration: 3a2b | Closing Coil MC: DC200V rated DC200-220V | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 10A | Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V | Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V | Durability: Same as the standard product | Type Approval Number: 2RY-14042 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396649058594,"sku":"MEL-FN-SRLDT5","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-srl-t5-1_eda89197-7252-4cfb-8b91-8b70e6ff3703.png?v=1790663060","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-srld-t5fn-class-2-heat-resistant-mechanical-latch-auxiliary-relay-10a-carrying-5a-4a1b-3a2b","provider":"ProSource MRO","version":"1.0","type":"link"}