{"product_id":"mitsubishi-electric-th-n220rhsr-th-n220hzsr-saturable-reactor-thermal-overload-relay-82-180a-n220-frame","title":"Mitsubishi Electric TH-N220RHSR \/ TH-N220HZSR Saturable Reactor Thermal Overload Relay (82-180A, N220 Frame)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric TH-N220RHSR \/ TH-N220HZSR saturable-reactor thermal overload relay, n220 frame, heater designations 82-180A.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eManual reset standard; auxiliary contact 1a1b\u003c\/li\u003e\n\u003cli\u003eCompliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eN220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eSaturable Reactor Thermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReset\u003c\/th\u003e\n\u003ctd\u003eManual (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e1a1b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eJIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220RHSR 82A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220RHSR saturable reactor thermal relay, 82A heater, 2-element | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 82A (adjustable 65-100A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220RHSR 105A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220RHSR saturable reactor thermal relay, 105A heater, 2-element | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 105A (adjustable 85-125A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220RHSR 125A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220RHSR saturable reactor thermal relay, 125A heater, 2-element | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 125A (adjustable 100-150A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220RHSR 150A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220RHSR saturable reactor thermal relay, 150A heater, 2-element | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 150A (adjustable 120-180A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220RHSR 180A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220RHSR saturable reactor thermal relay, 180A heater, 2-element | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 180A (adjustable 140-220A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220HZSR 82A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220HZSR saturable reactor thermal relay, 82A heater, 2-element | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 82A (adjustable 65-100A) | Mounting: Standalone mounting | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220HZSR 105A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220HZSR saturable reactor thermal relay, 105A heater, 2-element | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 105A (adjustable 85-125A) | Mounting: Standalone mounting | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220HZSR 125A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220HZSR saturable reactor thermal relay, 125A heater, 2-element | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 125A (adjustable 100-150A) | Mounting: Standalone mounting | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220HZSR 150A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220HZSR saturable reactor thermal relay, 150A heater, 2-element | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 150A (adjustable 120-180A) | Mounting: Standalone mounting | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220HZSR 180A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220HZSR saturable reactor thermal relay, 180A heater, 2-element | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 180A (adjustable 140-220A) | Mounting: Standalone mounting | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220RHKPSR 82A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220RHKPSR saturable reactor thermal relay, 82A heater, 3-element 2E | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 82A (adjustable 65-100A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220RHKPSR 105A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220RHKPSR saturable reactor thermal relay, 105A heater, 3-element 2E | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 105A (adjustable 85-125A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220RHKPSR 125A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220RHKPSR saturable reactor thermal relay, 125A heater, 3-element 2E | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 125A (adjustable 100-150A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220RHKPSR 150A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220RHKPSR saturable reactor thermal relay, 150A heater, 3-element 2E | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 150A (adjustable 120-180A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220RHKPSR 180A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220RHKPSR saturable reactor thermal relay, 180A heater, 3-element 2E | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 180A (adjustable 140-220A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220HZKPSR 82A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220HZKPSR saturable reactor thermal relay, 82A heater, 3-element 2E | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 82A (adjustable 65-100A) | Mounting: Standalone mounting | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220HZKPSR 105A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220HZKPSR saturable reactor thermal relay, 105A heater, 3-element 2E | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 105A (adjustable 85-125A) | Mounting: Standalone mounting | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220HZKPSR 125A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220HZKPSR saturable reactor thermal relay, 125A heater, 3-element 2E | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 125A (adjustable 100-150A) | Mounting: Standalone mounting | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220HZKPSR 150A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220HZKPSR saturable reactor thermal relay, 150A heater, 3-element 2E | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 150A (adjustable 120-180A) | Mounting: Standalone mounting | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-N220HZKPSR 180A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-N220HZKPSR saturable reactor thermal relay, 180A heater, 3-element 2E | Frame: N220 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 180A (adjustable 140-220A) | Mounting: Standalone mounting | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396638015778,"sku":"MEL-TH-N220SR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/MSTN_photo_TH_2-1_99d142f5-554b-4e01-b542-c3553a24dce4.png?v=1790662787","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-th-n220rhsr-th-n220hzsr-saturable-reactor-thermal-overload-relay-82-180a-n220-frame","provider":"ProSource MRO","version":"1.0","type":"link"}