{"product_id":"mitsubishi-electric-th-t50fs-th-t50fskp-quick-response-thermal-overload-relay-29-42a-t50-frame","title":"Mitsubishi Electric TH-T50FS \/ TH-T50FSKP Quick-Response Thermal Overload Relay (29-42A, T50 Frame)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric TH-T50FS \/ TH-T50FSKP quick-response thermal overload relay, t50 frame, heater designations 29-42A, trip class 5.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFaster operating time than standard TH types for motors with short locked-rotor withstand time such as submersible motors; usable from DC to 400Hz. 2-element type for overload protection, FSKP 3-element (2E) type for combined overload and open-phase protection\u003c\/li\u003e\n\u003cli\u003eManual reset standard; auxiliary contact 1a1b\u003c\/li\u003e\n\u003cli\u003eCompliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003eT50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eQuick-Response Thermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip Class\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eFor magnetic starter combination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReset\u003c\/th\u003e\n\u003ctd\u003eManual (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAux Contact\u003c\/th\u003e\n\u003ctd\u003e1a1b\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003eDC to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eJIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-T50FS 29A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-T50FS quick-response thermal relay, 29A heater, 2-element | Frame: T50 | Type: Quick-Response Thermal Overload Relay | Elements: 2-element | Protection: Overload | Trip Class: 5 | Heater: 29A (adjustable 24-34A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Frequency: DC to 400Hz | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-T50FS 35A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-T50FS quick-response thermal relay, 35A heater, 2-element | Frame: T50 | Type: Quick-Response Thermal Overload Relay | Elements: 2-element | Protection: Overload | Trip Class: 5 | Heater: 35A (adjustable 30-40A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Frequency: DC to 400Hz | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-T50FS 42A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-T50FS quick-response thermal relay, 42A heater, 2-element | Frame: T50 | Type: Quick-Response Thermal Overload Relay | Elements: 2-element | Protection: Overload | Trip Class: 5 | Heater: 42A (adjustable 34-50A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Frequency: DC to 400Hz | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-T50FSKP 29A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-T50FSKP quick-response thermal relay, 29A heater, 3-element 2E | Frame: T50 | Type: Quick-Response Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Trip Class: 5 | Heater: 29A (adjustable 24-34A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Frequency: DC to 400Hz | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-T50FSKP 35A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-T50FSKP quick-response thermal relay, 35A heater, 3-element 2E | Frame: T50 | Type: Quick-Response Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Trip Class: 5 | Heater: 35A (adjustable 30-40A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Frequency: DC to 400Hz | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTH-T50FSKP 42A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTH-T50FSKP quick-response thermal relay, 42A heater, 3-element 2E | Frame: T50 | Type: Quick-Response Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Trip Class: 5 | Heater: 42A (adjustable 34-50A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Frequency: DC to 400Hz | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396638179618,"sku":"MEL-TH-T50FS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/MSTN_photo_TH_1-1_05dea615-1cc6-4e7d-9112-0318bf78760b.png?v=1790662792","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-th-t50fs-th-t50fskp-quick-response-thermal-overload-relay-29-42a-t50-frame","provider":"ProSource MRO","version":"1.0","type":"link"}