{"product_id":"mitsubishi-electric-un-yg-ut-un-yd-short-circuiting-conductor-kits-3-pole-and-2-pole","title":"Mitsubishi Electric UN-YG, UT\/UN-YD Short-Circuiting Conductor Kits (3-Pole and 2-Pole)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric UN-YG 3-pole and UT\/UN-YD 2-pole short-circuiting conductor kits for MS-T\/N magnetic contactor main circuit terminals.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eTwo conductors are required to form a 3-pole parallel circuit (YG) or 3-pole series circuit (YD)\u003c\/li\u003e\n\u003cli\u003eYG21 to YG80 and YD21 to YD80 mount directly on the contactor terminals; larger sizes require arc box removal during installation\u003c\/li\u003e\n\u003cli\u003eWhen used on the power supply side, install after coil wiring\u003c\/li\u003e\n\u003cli\u003eNot combinable with UN-CZ live-part protective covers\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YG21\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3-pole short-circuiting conductor UN-YG21, frame T21, T25, T32 | Type: 3-pole short-circuiting | Applicable Frame: T21, T25, T32 | Note: 2 conductors per parallel circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YG25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3-pole short-circuiting conductor UN-YG25, frame T35, T50, N38, N48 | Type: 3-pole short-circuiting | Applicable Frame: T35, T50, N38, N48 | Note: 2 conductors per parallel circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YG50\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3-pole short-circuiting conductor UN-YG50, frame T65, T80 | Type: 3-pole short-circuiting | Applicable Frame: T65, T80 | Note: 2 conductors per parallel circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YG80\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3-pole short-circuiting conductor UN-YG80, frame T100, N125 | Type: 3-pole short-circuiting | Applicable Frame: T100, N125 | Note: 2 conductors per parallel circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YG150\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3-pole short-circuiting conductor UN-YG150, frame N150 | Type: 3-pole short-circuiting | Applicable Frame: N150 | Note: 2 conductors per parallel circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YG220\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3-pole short-circuiting conductor UN-YG220, frame N180, N220 | Type: 3-pole short-circuiting | Applicable Frame: N180, N220 | Note: 2 conductors per parallel circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YG300\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3-pole short-circuiting conductor UN-YG300, frame N300, N400 | Type: 3-pole short-circuiting | Applicable Frame: N300, N400 | Note: 2 conductors per parallel circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-YD20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole short-circuiting conductor UT-YD20, frame T10, T12, T20 | Type: 2-pole short-circuiting | Applicable Frame: T10, T12, T20 | Note: 2 conductors per series circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YD21\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole short-circuiting conductor UN-YD21, frame T21, T25, T32 | Type: 2-pole short-circuiting | Applicable Frame: T21, T25, T32 | Note: 2 conductors per series circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YD25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole short-circuiting conductor UN-YD25, frame T35, T50, N38, N48 | Type: 2-pole short-circuiting | Applicable Frame: T35, T50, N38, N48 | Note: 2 conductors per series circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YD50\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole short-circuiting conductor UN-YD50, frame T65, T80 | Type: 2-pole short-circuiting | Applicable Frame: T65, T80 | Note: 2 conductors per series circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YD80\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole short-circuiting conductor UN-YD80, frame T100, N125 | Type: 2-pole short-circuiting | Applicable Frame: T100, N125 | Note: 2 conductors per series circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YD150\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole short-circuiting conductor UN-YD150, frame N150 | Type: 2-pole short-circuiting | Applicable Frame: N150 | Note: 2 conductors per series circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YD220\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole short-circuiting conductor UN-YD220, frame N180, N220 | Type: 2-pole short-circuiting | Applicable Frame: N180, N220 | Note: 2 conductors per series circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-YD300\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole short-circuiting conductor UN-YD300, frame N300, N400 | Type: 2-pole short-circuiting | Applicable Frame: N300, N400 | Note: 2 conductors per series circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396645028130,"sku":"MEL-OPT-YGYD","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-opt-ygyd-1.png?v=1790662964","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-un-yg-ut-un-yd-short-circuiting-conductor-kits-3-pole-and-2-pole","provider":"ProSource MRO","version":"1.0","type":"link"}