{"product_id":"mitsubishi-electric-ut-un-ax-auxiliary-contact-units-for-ms-t-n-contactors-and-relays","title":"Mitsubishi Electric UT\/UN-AX Auxiliary Contact Units for MS-T\/N Contactors and Relays","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric UT-AX and UN-AX auxiliary contact units add extra auxiliary contacts to MS-T\/N series magnetic contactors and contactor relays without special tools.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eTwin contacts throughout for high contact reliability, suitable for low-level signals\u003c\/li\u003e\n\u003cli\u003eHead ON and slim Side ON mounting types; UT-AX(BC) types have wiring-rationalized terminals and UN-AX(CX) types have CAN terminals\u003c\/li\u003e\n\u003cli\u003eSelectable contact arrangements on AX2 (2a, 1a1b, 2b) and AX4 (4a, 3a1b, 2a2b); AX11\/AX80\/AX150 fixed 1a1b, AX600 fixed 2a2b\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage 690V, Ith 10A\u003c\/li\u003e\n\u003cli\u003eConforms to JIS C8201-5-1, IEC 60947-5-1, EN 60947-5-1, GB14048.5\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX2 2A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX2, 2a, Head ON | Contacts: 2a | Mounting: Head ON | Terminal: Screw | Applicable: S-T10 to T50, SR-T5 (AC) \/ SD-T12 to T50, SRD-T5 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX2 1A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX2, 1a1b, Head ON | Contacts: 1a1b | Mounting: Head ON | Terminal: Screw | Applicable: S-T10 to T50, SR-T5 (AC) \/ SD-T12 to T50, SRD-T5 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX2 2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX2, 2b, Head ON | Contacts: 2b | Mounting: Head ON | Terminal: Screw | Applicable: S-T10 to T50, SR-T5 (AC) \/ SD-T12 to T50, SRD-T5 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX2BC 2A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX2BC, 2a, Head ON | Contacts: 2a | Mounting: Head ON | Terminal: Wiring-rationalized (BC) | Applicable: S-T10BC to T50BC, SR-T5BC group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX2BC 1A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX2BC, 1a1b, Head ON | Contacts: 1a1b | Mounting: Head ON | Terminal: Wiring-rationalized (BC) | Applicable: S-T10BC to T50BC, SR-T5BC group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX2BC 2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX2BC, 2b, Head ON | Contacts: 2b | Mounting: Head ON | Terminal: Wiring-rationalized (BC) | Applicable: S-T10BC to T50BC, SR-T5BC group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX4 4A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX4, 4a, Head ON | Contacts: 4a | Mounting: Head ON | Terminal: Screw | Applicable: S-T10 to T50, SR-T5 (AC) \/ SD-T12 to T50, SRD-T5 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX4 3A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX4, 3a1b, Head ON | Contacts: 3a1b | Mounting: Head ON | Terminal: Screw | Applicable: S-T10 to T50, SR-T5 (AC) \/ SD-T12 to T50, SRD-T5 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX4 2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX4, 2a2b, Head ON | Contacts: 2a2b | Mounting: Head ON | Terminal: Screw | Applicable: S-T10 to T50, SR-T5 (AC) \/ SD-T12 to T50, SRD-T5 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX4BC 4A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX4BC, 4a, Head ON | Contacts: 4a | Mounting: Head ON | Terminal: Wiring-rationalized (BC) | Applicable: S-T10BC to T50BC, SR-T5BC group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX4BC 3A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX4BC, 3a1b, Head ON | Contacts: 3a1b | Mounting: Head ON | Terminal: Wiring-rationalized (BC) | Applicable: S-T10BC to T50BC, SR-T5BC group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX4BC 2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX4BC, 2a2b, Head ON | Contacts: 2a2b | Mounting: Head ON | Terminal: Wiring-rationalized (BC) | Applicable: S-T10BC to T50BC, SR-T5BC group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX2 2A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX2, 2a, Head ON | Contacts: 2a | Mounting: Head ON | Terminal: Screw | Applicable: S-T65, T80, S-N38, N48, DU-N30 (AC) \/ SD-T65, T80, DUD-N30 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX2 1A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX2, 1a1b, Head ON | Contacts: 1a1b | Mounting: Head ON | Terminal: Screw | Applicable: S-T65, T80, S-N38, N48, DU-N30 (AC) \/ SD-T65, T80, DUD-N30 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX2 2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX2, 2b, Head ON | Contacts: 2b | Mounting: Head ON | Terminal: Screw | Applicable: S-T65, T80, S-N38, N48, DU-N30 (AC) \/ SD-T65, T80, DUD-N30 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX2CX 2A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX2CX, 2a, Head ON | Contacts: 2a | Mounting: Head ON | Terminal: CAN (CX) | Applicable: S-T65CX, T80CX group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX2CX 1A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX2CX, 1a1b, Head ON | Contacts: 1a1b | Mounting: Head ON | Terminal: CAN (CX) | Applicable: S-T65CX, T80CX group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX2CX 2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX2CX, 2b, Head ON | Contacts: 2b | Mounting: Head ON | Terminal: CAN (CX) | Applicable: S-T65CX, T80CX group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX4 4A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX4, 4a, Head ON | Contacts: 4a | Mounting: Head ON | Terminal: Screw | Applicable: S-T65, T80, S-N38, N48, DU-N30 (AC) \/ SD-T65, T80, DUD-N30 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX4 3A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX4, 3a1b, Head ON | Contacts: 3a1b | Mounting: Head ON | Terminal: Screw | Applicable: S-T65, T80, S-N38, N48, DU-N30 (AC) \/ SD-T65, T80, DUD-N30 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX4 2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX4, 2a2b, Head ON | Contacts: 2a2b | Mounting: Head ON | Terminal: Screw | Applicable: S-T65, T80, S-N38, N48, DU-N30 (AC) \/ SD-T65, T80, DUD-N30 (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX4CX 4A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX4CX, 4a, Head ON | Contacts: 4a | Mounting: Head ON | Terminal: CAN (CX) | Applicable: S-T65CX, T80CX group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX4CX 3A1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX4CX, 3a1b, Head ON | Contacts: 3a1b | Mounting: Head ON | Terminal: CAN (CX) | Applicable: S-T65CX, T80CX group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX4CX 2A2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX4CX, 2a2b, Head ON | Contacts: 2a2b | Mounting: Head ON | Terminal: CAN (CX) | Applicable: S-T65CX, T80CX group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX11\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX11, 1a1b fixed, Side ON | Contacts: 1a1b (fixed) | Mounting: Side ON | Terminal: Screw | Applicable: S-T10 to T50, SR-T5, SL(D)-T21\/T35\/T50, SRL(D)-T5 | Max Units: Up to 2 units (reversing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUT-AX11BC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UT-AX11BC, 1a1b fixed, Side ON | Contacts: 1a1b (fixed) | Mounting: Side ON | Terminal: Wiring-rationalized (BC) | Applicable: BC terminal group of the above | Max Units: Up to 2 units (reversing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX11\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX11, 1a1b fixed, Side ON | Contacts: 1a1b (fixed) | Mounting: Side ON | Terminal: Screw | Applicable: S-T65, T80, DU-N30, SL(D)-T65\/T80 | Max Units: Up to 2 units (reversing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX11CX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX11CX, 1a1b fixed, Side ON | Contacts: 1a1b (fixed) | Mounting: Side ON | Terminal: CAN (CX) | Applicable: CX terminal group of the above | Max Units: Up to 2 units (reversing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX80\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX80, 1a1b fixed, Side ON | Contacts: 1a1b (fixed) | Mounting: Side ON | Terminal: Screw | Applicable: S-T100, S-N125, DU-N60, SL(D)-T100\/N125 | Max Units: Up to 2 units (left\/right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX150\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX150, 1a1b fixed, Side ON | Contacts: 1a1b (fixed) | Mounting: Side ON | Terminal: Screw | Applicable: S-N150 to N400, DU-N120\/N180\/N260, SL(D)-N150 to N400 | Max Units: Up to 2 units (left\/right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUN-AX600\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact unit UN-AX600, 2a2b fixed, Side ON | Contacts: 2a2b (fixed) | Mounting: Side ON | Terminal: Screw | Applicable: S-N600, N800, SL(D)-N600\/N800 | Max Units: 1 unit (right side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396644733218,"sku":"MEL-OPT-AX","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/Mstn-photo-opt-ax-1.png?v=1790662956","url":"https:\/\/prosourcemro.com\/products\/mitsubishi-electric-ut-un-ax-auxiliary-contact-units-for-ms-t-n-contactors-and-relays","provider":"ProSource MRO","version":"1.0","type":"link"}